Assessment of a Rapid Method to Determine Approximate Visual Acuity in Large Surveys and Other Such Settings

被引:6
作者
Arora, Karun S. [1 ]
Chang, Dolly S. [1 ]
Supakontanasan, Wasu [1 ]
Lakkur, Manu [1 ]
Friedman, David S. [1 ]
机构
[1] Johns Hopkins Univ Hosp, Glaucoma Ctr Excellence, Wilmer Eye Inst, Baltimore, MD 21287 USA
关键词
IMPAIRMENT; VISION; HEALTH;
D O I
10.1016/j.ajo.2014.02.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the efficacy of an iPod application developed to rapidly measure approximate visual acuity (VA). DESIGN: Prospective, cross-sectional study. METHODS: One hundred four subjects (104 eyes) with a wide range of VA underwent both Early Treatment Diabetic Retinopathy Study (ETDRS) VA testing and iPod application testing. The application presented 4 randomized ETDRS letters at the Snellen equivalent of 20/40 and 20/200 each. In separate analyses, sensitivity and specificity of the iPod test were determined using the ETDRS VA testing results as the gold standard and defining "failure" to see as identifying 1, 2, 3, or all 4 letters incorrectly out of 4 trials. The minimum number of iPod trials necessary to maintain high accuracy was determined by defining a "failure" as getting the first, first 2, first 3, or all trial letters incorrect. In 13 subjects, the time necessary to perform the testing was determined. RESULTS: Forty-six subjects had an ETDRS Snellen equivalent VA >= 20/40; 45 had a VA <20/40 and >= 20/200; and 13 had a VA <20/200. The mean +/- SD testing time for the 3 groups was 43 +/- 13, 60 +/- 15, and 72 +/- 25 seconds, respectively. The highest sensitivity and specificity combination was observed when a "failure" was defined as getting all letters incorrect for both the 20/40 (sensitivity = 98.3%/specificity = 93.5%) and 20/200 (sensitivity/specificity both 92.3%) cutoffs. CONCLUSIONS: An iPod application requiring about a 1-minute testing time provides an objective, portable, rapid, and low-cost method to determine approximate VA, allowing VA testing to be performed efficiently in large surveys and other settings where approximate VA should be measured. (C) 2014 by Elsevier Inc. All rights reserved.
引用
收藏
页码:1315 / 1321
页数:7
相关论文
共 11 条
[1]  
[Anonymous], 1991, OPHTHALMOLOGY, V98, P741
[2]  
BAILEY IL, 1991, INVEST OPHTH VIS SCI, V32, P422
[3]  
Centers for Disease Control and Prevention, 2011, BUILD BASIS ACT ENH
[4]   Assessment of the effect of visual impairment on mortality through multiple health pathways: Structural equation modeling [J].
Christ, Sharon L. ;
Lee, David J. ;
Lam, Byron L. ;
Zheng, D. Diane ;
Arheart, Kristopher L. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) :3318-3323
[5]   Discrepancies in the Concordance of Self-Reported Vision Status and Visual Acuity in the Salisbury Eye Evaluation Study [J].
El-Gasim, Mahmood ;
Munoz, Beatriz ;
West, Sheila K. ;
Scott, Adrienne W. .
OPHTHALMOLOGY, 2012, 119 (01) :106-111
[6]   NEW VISUAL-ACUITY CHARTS FOR CLINICAL RESEARCH [J].
FERRIS, FL ;
KASSOFF, A ;
BRESNICK, GH ;
BAILEY, I .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1982, 94 (01) :91-96
[7]  
Friedman SM, 1999, INVEST OPHTH VIS SCI, V40, P858
[8]  
Kulmala J, 2008, AGING CLIN EXP RES, V20, P25
[9]   The association between visual acuity and functional limitations: Findings from a nationally representative population survey [J].
Laitinen, Arja ;
Sainio, Paeivi ;
Koskinen, Seppo ;
Rudanko, Sirkka-Liisa ;
Laatikainen, Leila ;
Aromaa, Arpo .
OPHTHALMIC EPIDEMIOLOGY, 2007, 14 (06) :333-342
[10]  
West SK, 2002, ARCH OPHTHALMOL-CHIC, V120, P774