Assessment of pupil size under different light intensities using the Procyon pupillometer

被引:24
|
作者
Cheng, Arthur C. K. [1 ]
Rao, Srinivas K. [1 ]
Cheng, Lulu L. [1 ]
Lam, Dennis S. C. [1 ]
机构
[1] Chinese Univ Hong Kong, Univ Eye Ctr, Dept Ophthalmol & Visual Sci, Hong Kong Eye Hosp, Kowloon, Hong Kong, Peoples R China
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2006年 / 32卷 / 06期
关键词
D O I
10.1016/j.jcrs.2006.02.033
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the relationship between pupil size and light intensity using the Procyon pupillometer. SETTING: University based clinic. METHODS: In this retrospective study, 20 consecutive patients had pupil size assessment with the Procyon pupillometer under 3 different light conclitions-4, 0.4, and 0.04 lux. Correlation was established using the log unit of the light intensity and pupil size. RESULTS: The correlation coefficient for the association between pupil size and log unit of light intensity in all eyes was significant (P<.001). The mean correlation coefficient for the association between pupil size and log unit of light intensity in all patients was 0.968 +/- 0.089 (SD) in the right eye and 0.970 +/- 0.031 in the left eye. CONCLUSION: The linear relationship between the pupil size and the log unit of the light intensity showed a tight correlation in all cases. These results can be useful in the comparing pupil size with pupillometers that work under different light conditions.
引用
收藏
页码:1015 / 1017
页数:3
相关论文
共 50 条
  • [1] Pupil size measurements with the procyon pupillometer
    Netto, MV
    Ambrosio, R
    Wilson, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U21 - U21
  • [2] Automated Pupillometer Using Edge Detection in OpenCV for Pupil Size and Reactivity Assessment
    Garcia, Ramon G.
    Avendano, Glenn O.
    Agdeppa, Denzel Blake F.
    Castillo, Ken J.
    Go, Neil Roger S. D.
    Mesina, Mikhail A.
    2019 3RD INTERNATIONAL CONFERENCE ON IMAGING, SIGNAL PROCESSING AND COMMUNICATION (ICISPC), 2019, : 143 - 149
  • [3] Using smartphone pupillometer application to measure pupil size and light reflex: An unsuccessful prototype and analysis of the causes of failure
    Tan, Hung-Hsi
    Lee, Kuo-Chang
    Chen, Yi-Rong
    Huang, Yu-Chin
    Ke, Rih-Shen
    Horng, Gwo-Jiun
    Chen, Kuo-Tai
    MEDICINE, 2025, 104 (09)
  • [4] PUPIL SIZE UNDER DIFFERENT LIGHTING SOURCES
    Rossi, L.
    Zegna, L.
    Iacomussi, P.
    Rossi, G.
    PROCEEDINGS OF CIE 2012 LIGHTING QUALITY AND ENERGY EFFICIENCY, 2012, : 450 - 459
  • [5] PUPIL SIZE UNDER DIFFERENT LIGHTING SOURCES
    Rossi, Laura
    Zegna, Ludovico
    Iacomussi, Paola
    Rossi, Giuseppe
    LIGHT & ENGINEERING, 2013, 21 (01): : 40 - 48
  • [6] Characterisation of pupil responses to alternating light intensities across different cognitive tasks
    Beckers, E.
    Campbell, I.
    Paparella, I.
    Sharifpour, R.
    Koshmanova, E.
    Berger, A.
    Aizpurua, J. F. Balda
    Mortazavi, N.
    Talwar, P.
    Sherif, S.
    Jacobs, H.
    Vandewalle, G.
    JOURNAL OF SLEEP RESEARCH, 2022, 31
  • [7] Measurement of the Pupil Diameter Under Different Light Stimula
    Masi, M. Gabriella
    Peretto, Lorenzo
    Tinarelli, Roberto
    Rovati, Luigi
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1605 - +
  • [8] Differences of the Pupil Response During Exposure to Light of Different Spectral Compositions and Intensities: Preliminary Findings
    de Zeeuw, Jan
    Nowozin, Claudia
    Wisniewski, Sophia
    Papakonstantinou, Alexandra
    Zaleska, Mandy
    Fox, Theresa
    Haedel, Sven
    Kunz, Dieter
    Muench, Mirjam
    NEUROPSYCHOBIOLOGY, 2016, 74 (04) : 235 - 236
  • [9] Intrasession repeatability of pupil size measurements under different light levels provided by a multidiagnostic device in healthy eyes
    Pinero, David P.
    de Fez, Dolores
    Cabezos, Inmaculada
    Lopez-Navarro, Alberto
    Caballero, Maria T.
    Camps, Vicente J.
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [10] Intrasession repeatability of pupil size measurements under different light levels provided by a multidiagnostic device in healthy eyes
    David P. Piñero
    Dolores de Fez
    Inmaculada Cabezos
    Alberto López-Navarro
    María T. Caballero
    Vicente J. Camps
    BMC Ophthalmology, 20