Evaluation of optical and radio-photoluminescence properties in Ag-doped 30KPO3-70Al(PO3)3 glasses

被引:14
作者
Shiratori, Daiki [1 ]
Isokawa, Yuya [1 ]
Samizo, Hayata [1 ]
Kawaguchi, Noriaki [1 ]
Yanagida, Takayuki [1 ]
机构
[1] Nara Inst Sci & Technol, 8916-5 Takayama, Ikoma, Nara 6300192, Japan
关键词
Glass; Radio-photoluminescence; Dosimeter; DOSIMETER PROPERTIES; SILVER; LUMINESCENCE; SCINTILLATION; DETECTORS; CRYSTAL; CENTERS; ENERGY;
D O I
10.2109/jcersj2.19058
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We prepared glass samples with a chemical composition of 30KPO(3)-70Al(PO3)(3) by the melt quenching method. As a radio-photoluminescence (RPL) emission center, Ag2O (0, 0.1, 0.3, 1.0 and 3.0%) was doped in these glasses. Before X-ray irradiation, Ag-doped samples showed a blue luminescence upon 254 nm excitation while they exhibited an orangish luminescence upon 304 nm excitation after X-ray irradiation. We evaluated dosimeter properties such as dose response properties of RPL, fading and thermally stimulated luminescence (TSL) glow curves. Dose response function in RPL emission indicated the lower detection limit of 100 mGy. In addition, TSL glow curve of Ag-doped 30KPO(3)-70Al(PO3)(3) showed that accumulated carriers in the samples were released at around 85 degrees C and easily re-excited at room temperature. (C) 2019 The Ceramic Society of Japan. All rights reserved.
引用
收藏
页码:455 / 461
页数:7
相关论文
共 31 条
  • [1] [Anonymous], 2011, OPTICALLY STIMULATED, DOI DOI 10.1093/RPD/NCR357
  • [2] BOS AJJ, 1991, RADIAT PROT DOSIM, V37, P231
  • [3] Optical decay of OSL signal of Al2O3: C detectors exposed to different light sources
    Gronchi, C. C.
    Cecatti, S. G. P.
    Pinto, T. C. N. O.
    Caldas, L. V. E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2008, 266 (12-13) : 2915 - 2917
  • [4] Huang D. Y. C., 2011, ADV CANCER THER
  • [5] The BeOmax system - Dosimetry using OSL of BeO for several applications
    Jahn, A.
    Sommer, M.
    Ullrich, W.
    Wickert, M.
    Henniger, J.
    [J]. RADIATION MEASUREMENTS, 2013, 56 : 324 - 327
  • [6] Optically stimulated luminescence radiation dosimetry using doped silica glass
    Justus, BL
    Rychnovsky, S
    Miller, MA
    Pawlovich, KJ
    Huston, AL
    [J]. RADIATION PROTECTION DOSIMETRY, 1997, 74 (03) : 151 - 154
  • [7] The effect of heating rate on the dose dependence and thermoluminescence characteristics of CaSO4: Dy (TLD-900)
    Kafadar, V. Emir
    Majeed, Karwan F.
    [J]. THERMOCHIMICA ACTA, 2014, 590 : 266 - 269
  • [8] The effects of heating rate on the dose response characteristics of TLD-200, TLD-300 and TLD-400
    Kafadar, V. Emir
    Yazici, A. Necmeddin
    Yildirim, R. Gueler
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (19) : 3337 - 3346
  • [9] Investigation into the properties of CdTe detectors for in-situ measurements
    Kastlander, J.
    Bargholtz, Chr.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 596 (03) : 409 - 416
  • [10] Thermoluminescence glow-curve deconvolution functions for first, second and general orders of kinetics
    Kitis, G
    Gomez-Ros, JM
    Tuyn, JWN
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (19) : 2636 - 2641