3D-OSEM iterative image reconstruction for high-resolution PET using precalculated system matrix

被引:18
|
作者
Ortuno, Juan E. [1 ]
Guerra-Gutiérrez, Pedro [1 ]
Rubio, Jose L. [1 ]
Kontaxakis, George [1 ]
Santos, Andres [1 ]
机构
[1] Univ Politecn Madrid, Dept Elect Engn, E-28040 Madrid, Spain
关键词
image reconstruction; small animal PET; Monte Carlo simulation; system matrix;
D O I
10.1016/j.nima.2006.08.067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An efficient iterative image reconstruction methodology is presented, adapted to high-resolution flat-head 3D positron emission tomography cameras. It is based on the ordered subsets expectation maximization algorithm and applies to systems with axial symmetry. The associated system matrix is calculated off-line, including a model of the gamma-event detection in the crystal, taking into account photoelectric effect and Compton scattering interactions. The nonzero elements of the sparse system matrix are stored in disc in an efficient way that allows the fast sequential access to the matrix elements during the reconstruction. A detailed calculation is performed for the voxels corresponding to central plane within the field of view (FOV) of the camera and the remaining values of the system matrix are obtained via translations based on the symmetries of the system along the axial dimension. GATE-based simulations have been used for the validation of the results. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:440 / 444
页数:5
相关论文
共 50 条
  • [1] Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction
    Olesen, Oline Vinter
    Sibomana, Merence
    Keller, Sune Hogild
    Andersen, Flemming
    Jensen, Jorgen
    Holm, Soren
    Svarer, Claus
    Hojgaard, Liselotte
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3789 - 3790
  • [2] Comparison of 3-D reconstruction with 3D-OSEM and with FORE plus OSEM for PET
    Liu, X
    Comtat, C
    Michel, C
    Kinahan, P
    Defrise, M
    Townsend, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (08) : 804 - 814
  • [3] Weighted schemes applied to 3D-OSEM reconstruction in PET
    Michel, C
    Liu, X
    Sanabria, S
    Lonneux, M
    Sibomana, M
    Bol, A
    Comtat, C
    Kinahan, PE
    Townsend, DW
    Defrise, M
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1152 - 1157
  • [4] High resolution reconstruction of PET images using the iterative OSEM algorithm
    Doll, J
    Henze, M
    Bublitz, O
    Werling, A
    Adam, LE
    Haberkorn, U
    Semmler, W
    Brix, G
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2004, 43 (03): : 72 - 78
  • [5] 3D-OSEM transition matrix for high resolution PET imaging with modeling of the gamma-event detection
    Ortuño, JE
    Kontaxakis, G
    Guerra, P
    Santos, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3046 - 3050
  • [6] Efficient methodologies for system matrix modelling in iterative image reconstruction for rotating high-resolution PET
    Ortuno, J. E.
    Kontaxakis, G.
    Rubio, J. L.
    Guerra, P.
    Santos, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1833 - 1861
  • [7] Multi-grid 3D-OSEM reconstruction technique for high resolution rotating-head PET scanners
    Ortuno, Juan E.
    Rubio, Jose L.
    Guerra, Pedro
    Kontaxakis, George
    Santos, Andres
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2215 - 2218
  • [8] Full 3D-OSEM reconstruction with compressed response of the system
    Herraiz, JL
    España, S
    Vaquero, JJ
    Desco, M
    Udias, JM
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2952 - 2956
  • [9] PET Image Reconstruction Using LOR-OSEM with a 3D Spatially Variant System Matrix
    Wiant, David B.
    Gersh, Jacob A.
    Bennett, Marcus C.
    Bourland, J. Daniel
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3752 - 3758
  • [10] Accelerated 3D-OSEM image reconstruction using a Beowulf PC cluster for pinhole SPECT
    Zeniya, Tsutomu
    Watabe, Hiroshi
    Sohlberg, Antti
    Iida, Hidehiro
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (09) : 537 - 543