Evaluation of wind-driven natural ventilation of single-span greenhouses built on reclaimed coastal land

被引:45
作者
Lee, Sang-yeon [1 ]
Lee, In-bok [1 ,2 ]
Kim, Rack-woo [1 ]
机构
[1] Seoul Natl Univ, Coll Agr & Life Sci, Res Inst Agr & Life Sci, Dept Rural Syst Engn, 1 Gwanakno, Seoul 08826, South Korea
[2] Seoul Natl Univ, Inst Green Bio Sci & Technol, Res Inst Green Eco Engn, 1477 Pyeongchang Daero, Pyeongchang Gun 25354, Gangwon Do, South Korea
关键词
Computational fluid dynamics; Natural ventilation rate; Particle image velocimetry; Reclaimed land; Single-span greenhouse; MULTISPAN GREENHOUSES; NUMERICAL-SIMULATION; TUNNEL; VERIFICATION; EFFICIENCY; MODEL; ROOF;
D O I
10.1016/j.biosystemseng.2018.04.015
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Recently, the government of South Korea announced the construction plan for a large-scale greenhouse complex on reclaimed coastal lands. Wind characteristics of the coastal regions are quite different from those of inland. Natural ventilation of greenhouses is strongly dependent on the exterior wind characteristics; therefore, the effects of topographical and meteorological characteristics of the coastal regions on ventilation rate should be carefully evaluated to ensure stable and uniform production of the crops. In this study, wind-driven natural ventilation rates of single-span greenhouses were evaluated using a computational fluid dynamics (CFD) technique examining greenhouse type and typical wind conditions found in reclaimed lands. The accuracy of the designed CFD model was validated by comparing the result of the CFD simulation with the results of particle image velocimetry (PIV) measurements that were conducted in a wind tunnel. Furthermore, grid independence test and turbulence model test were conducted for validation of the designed CFD model. From these validated CFD model, the overall ventilation rates were estimated using two methods, mass flow rate (MFR) and tracer gas decay (TGD) methods according to greenhouse type, wind speed, wind direction, and configuration of the ventilator. Furthermore, local ventilation rates of the greenhouse were estimated using the TGD method. The CFD computed ventilation rates of greenhouses were evaluated by comparing them with the ventilation rates required for controlling the temperature in greenhouses. Finally, charts, which can be used to predict the natural ventilation rate of the single-span greenhouse built on reclaimed land, were developed. (C) 2018 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:120 / 142
页数:23
相关论文
共 68 条
[1]  
Aich W., 2016, Therm. Sci, V52, P1
[2]   Analysis of the role of sidewall vents on buoyancy-driven natural ventilation in parral-type greenhouses with and without insect screens using computational fluid dynamics [J].
Baeza, Esteban J. ;
Perez-Parra, Jeronimo J. ;
Montero, Juan I. ;
Bailey, Bernard J. ;
Lopez, Juan C. ;
Gazquez, Juan C. .
BIOSYSTEMS ENGINEERING, 2009, 104 (01) :86-96
[3]   Effect of vent arrangement on windward ventilation of a tunnel greenhouse [J].
Bartzanas, T ;
Boulard, T ;
Kittas, C .
BIOSYSTEMS ENGINEERING, 2004, 88 (04) :479-490
[4]   Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case [J].
Benni, Stefano ;
Tassinari, Patrizia ;
Bonora, Filippo ;
Barbaresi, Alberto ;
Torreggiani, Daniele .
ENERGY AND BUILDINGS, 2016, 125 :276-286
[5]   Air flow and associated sensible heat exchanges in a naturally ventilated greenhouse [J].
Boulard, T ;
Papadakis, G ;
Kittas, C ;
Mermier, M .
AGRICULTURAL AND FOREST METEOROLOGY, 1997, 88 (1-4) :111-119
[6]   Characterization and modelling of the air fluxes induced by natural ventilation in a greenhouse [J].
Boulard, T ;
Haxaire, R ;
Lamrani, MA ;
Roy, JC ;
Jaffrin, A .
JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 74 (02) :135-144
[7]   The mechanisms involved in the natural ventilation of greenhouses [J].
Boulard, T ;
Meneses, JF ;
Mermier, M ;
Papadakis, G .
AGRICULTURAL AND FOREST METEOROLOGY, 1996, 79 (1-2) :61-77
[8]  
Boumet P. E., 2007, BIOSYST ENG, V98, P224
[9]  
Bournet PE, 2007, T ASABE, V50, P201, DOI 10.13031/2013.22401
[10]   Effect of ventilator configuration on the distributed climate of greenhouses: A review of experimental and CFD studies [J].
Bournet, Pierre-Emmanuel ;
Boulard, Thierry .
COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2010, 74 (02) :195-217