Study of gluing and wire bonding for the Belle II Silicon Vertex Detector

被引:1
作者
Kang, K. H. [1 ]
Hara, K. [5 ]
Higuchi, T. [2 ]
Hyun, H. J. [1 ]
Jeon, H. B. [1 ]
Joo, C. W. [3 ]
Kah, D. H. [4 ]
Kim, H. J. [1 ]
Mibe, T. [5 ]
Onuki, Y. [6 ]
Park, H. [1 ]
Rao, K. K. [7 ]
Sato, N. [5 ]
Shimizu, N. [6 ]
Tanida, K. [3 ]
Tsuboyama, T. [5 ]
Uozumi, S. [1 ]
机构
[1] Kyungpook Natl Univ, Dept Phys, Taegu 702701, South Korea
[2] Univ Tokyo, Kavli IPMU WPI, Kashiwa, Chiba 2778583, Japan
[3] Seoul Natl Univ, Dept Phys, Seoul 151742, South Korea
[4] Agcy Def Dev, CBRN Directorate, Taejon 305600, South Korea
[5] KEK, High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[6] Univ Tokyo, Fac Sci, Dept Phys, Bunkyo Ku, Tokyo 1130033, Japan
[7] Tata Inst Fundamental Res, Expt High Energy Phys Grp, Bombay 400005, Maharashtra, India
基金
新加坡国家研究基金会;
关键词
Gluing; Wire bonding; Belle II; Silicon Vertex Detector; Silicon sensor; Pitch adapter; TRACKER; DESIGN; CHIP;
D O I
10.1016/j.nima.2014.06.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes an investigation into gluing and wire bonding for assembling the Silicon Vertex Detector (SVD) for the Belle II experiment at KEK in Japan. Optimizing the gluing of the silicon microstrip sensors, the support frame, and the readout Ilex cables is important for achieving the required mechanical precision. The wire bonding between the sensors and the readout electronic chips also needs special care to maximize the physics capability of the SVD. The silicon sensors and signal fan out Ilex circuits (pitch adapters) are glued and connected using wire bonding. We determine that gluing quality is important for achieving good bonding efficiency. The standard deviation in the glue thickness for the best result is measured to be 3.11 mu m. Optimal machine parameters for wire bonding are determined to be 70 mW power, 20 gf force, and 20 ms for the pitch adapter and GO mW power, 20 gf force, and 20 ms for the silicon strip sensors; these parameters provide a pull force of (10.92 +/- 0.72) gf. With these settings, 75% of the pitch adapters and 25% of the strip sensors experience the neck-broken type of break. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:255 / 259
页数:5
相关论文
共 11 条
[1]   The silicon sensors for the Compact Muon Solenoid tracker-design and qualification procedure [J].
Agram, JL ;
Angarano, MM ;
Assouak, S ;
Bergauer, T ;
Bilei, GM ;
Borrello, L ;
Brianzi, M ;
Civinini, C ;
Dierlamm, A ;
Dinu, N ;
Demaria, N ;
Feld, L ;
Focardi, E ;
Fontaine, JC ;
Forton, E ;
Furgeri, A ;
Gregoire, G ;
Hartmann, F ;
Honma, A ;
Juillot, P ;
Kartashov, D ;
Krammer, M ;
Macchiolo, A ;
Mannelli, M ;
Messineo, A ;
Migliore, E ;
Militaru, O ;
Plasecki, C ;
Santinelli, R ;
Sentenac, D ;
Servoli, L ;
Starodumov, A ;
Tonelli, G ;
Wang, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 517 (1-3) :77-93
[2]  
Dolezal Z., 2010, KEK Report 2010-1
[3]   Design and results from the APV25, a deep sub-micron CMOS front-end chip for the CMS tracker [J].
French, MJ ;
Jones, LL ;
Morrissey, Q ;
Neviani, A ;
Turchetta, R ;
Fulcher, J ;
Hall, G ;
Noah, E ;
Raymond, M ;
Cervelli, G ;
Moreira, P ;
Marseguerra, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 466 (02) :359-365
[4]   The Belle II Silicon Vertex Detector [J].
Friedl, M. ;
Ackermann, K. ;
Aihara, H. ;
Aziz, T. ;
Bergauer, T. ;
Bozek, A. ;
Campbell, A. ;
Dingfelder, J. ;
Drasal, Z. ;
Frankenberger, A. ;
Gadow, K. ;
Gfall, I. ;
Haba, J. ;
Hara, K. ;
Hara, T. ;
Higuchi, T. ;
Himori, S. ;
Irmler, C. ;
Ishikawa, A. ;
Joo, C. ;
Kah, D. H. ;
Kang, K. H. ;
Kato, E. ;
Kiesling, C. ;
Kodys, P. ;
Kohriki, T. ;
Koike, S. ;
Kvasnicka, P. ;
Marinas, C. ;
Mayekar, S. N. ;
Mibe, T. ;
Mohanty, G. B. ;
Moll, A. ;
Negishi, K. ;
Nakayama, H. ;
Natkaniec, Z. ;
Niebuhr, C. ;
Onuki, Y. ;
Ostrowicz, W. ;
Park, H. ;
Rao, K. K. ;
Ritter, M. ;
Rozanska, M. ;
Saito, T. ;
Sakai, K. ;
Sato, N. ;
Schmid, S. ;
Schnell, M. ;
Shimizu, N. ;
Steininger, H. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 :83-86
[5]  
HASHIMOTO S, 2004, 20044 KEK
[6]  
Higuchi Takeo, 2013, QUALITY MANAGEMENT T
[8]   A Low Mass On-Chip Readout Scheme for Double-Sided Silicon Strip Detectors [J].
Irmler, C. ;
Bergauer, T. ;
Frankenberger, A. ;
Friedl, M. ;
Gfall, I. ;
Higuchi, T. ;
Ishikawa, A. ;
Joo, C. ;
Kah, D. H. ;
Kang, K. H. ;
Rao, K. K. ;
Kato, E. ;
Mohanty, G. B. ;
Negishi, K. ;
Onuki, Y. ;
Shimizu, N. ;
Tsuboyama, T. ;
Valentan, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 732 :109-112
[9]   Building CMS pixel barrel detector modules [J].
Koenig, S. ;
Hoermann, Ch. ;
Horisberger, R. ;
Meier, B. ;
Rohe, T. ;
Streuli, S. ;
Weber, R. ;
Kaestli, H. Chr. ;
Erdmann, W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 582 (03) :776-780
[10]   The Belle-II DEPFET pixel detector: A step forward in vertexing in the superKEKB flavour factory [J].
Marinas, C. ;
Vos, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01) :59-63