Electroless Pd and Ag deposition kinetics of the composite Pd and Pd/Ag membranes synthesized from agitated plating baths

被引:53
|
作者
Ayturk, M. Engin [1 ]
Ma, Yi Hua [1 ]
机构
[1] Worcester Polytech Inst, Dept Chem Engn, CIMS, Worcester, MA 01609 USA
关键词
Hydrogen separation; Composite Pd and Pd/Ag membranes; Electroless plating; Kinetics; Atomic absorption spectroscopy; POROUS STAINLESS-STEEL; INTERMETALLIC DIFFUSION BARRIER; PALLADIUM-SILVER; HYDROGEN SEPARATION; ALLOY MEMBRANES; METHANE; THIN; MICROSTRUCTURE; PERFORMANCE; PERMEATION;
D O I
10.1016/j.memsci.2008.12.062
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The atomic absorption spectroscopy (AAS) has been successfully utilized for the measurement of the Pd and Ag ion concentrations in the plating baths and to elucidate the effects of temperature, initial metal ion and reducing agent concentrations and agitation on the electroless plating kinetics of Pd and Ag metals. The initial metal ion concentrations for Pd and Ag were varied over a range of 8.2-24.5 mM and 3.1-12.5 mM, respectively. The plating reactions were conducted in a constant temperature electroless plating bath over a temperature range of 20-60 degrees C and an initial hydrazine concentration range of 1.8-5.4 mM. It was found that the electroless plating of both Pd and Ag were strongly affected by the external mass transfer in the absence of bath agitation. The external mass transfer limitations for both Pd and Ag deposition have been minimized at or above an agitation rate of 400 rpm, resulting in a maximum conversion of the plating reaction at 60 degrees C and dramatically shortened plating times with the added advantage of uniform deposition morphology. The derivation of the differential rate laws and the estimation of the reaction orders and the activation energies for the electroless Pd and Ag kinetics were conducted via non-linear regression analysis based on the method of initial rates. For a constant-volume batch reactor, the integrated rate law was solved to calculate the conversion and the reactant concentrations as a function of plating time. The model fits were in good agreement with the experimental data. Furthermore, the bath agitation and the plating conditions used in the kinetics study were adopted for the synthesis of 16-20 mu m thick composite Pd/Ag membranes (10-12 wt% Ag) and a pure-Pd membrane with a hydrogen selective dense Pd layer as thin as 4.7 mu m. While hydrogen permeance of the Pd/Ag membranes A and B at 450 degrees C were 28 and 32 m(3)/m(2)-h-atm(0.5), the H-2 permeance for the 4.7 mu m thick pure-Pd membrane at 400 degrees C was as high as 63 m(3)/m(2)-h-atm(0.5). The long-term permeance testing of all the membranes synthesized from agitated plating baths resulted in a relatively slow leak growth due primarily to the improved morphology obtained via the bath agitation and modified plating conditions. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:233 / 245
页数:13
相关论文
共 50 条
  • [1] Electroless plating and permeation features of Pd and Pd/Ag hollow fiber composite membranes
    Nair, Balamurali Krishna R.
    Choi, Jun
    Harold, Michael P.
    JOURNAL OF MEMBRANE SCIENCE, 2007, 288 (1-2) : 67 - 84
  • [2] Copper deposition on Pd membranes by electroless plating
    Acha, E.
    van Delft, Y. C.
    Overbeek, J.
    Arias, P. L.
    Cambra, J. F.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (20) : 13114 - 13121
  • [3] SIMULTANEOUS DEPOSITION OF PD AND AG ON POROUS STAINLESS-STEEL BY ELECTROLESS PLATING
    SHU, J
    GRANDJEAN, BPA
    GHALI, E
    KALIAGUINE, S
    JOURNAL OF MEMBRANE SCIENCE, 1993, 77 (2-3) : 181 - 195
  • [4] Synthesis of Pd-Ag Membranes by Electroless Plating for H2 Separation
    Li Yaning
    Kang Xinting
    Tang Huiping
    Wang Jian
    RARE METAL MATERIALS AND ENGINEERING, 2017, 46 (12) : 3688 - 3692
  • [5] Synthesis of Pd-Ag Membranes by Electroless Plating for H2 Separation
    Li, Yaning
    Kang, Xinting
    Tang, Huiping
    Wang, Jian
    Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering, 2017, 46 (12): : 3688 - 3692
  • [6] Effects of osmosis on microstructure of Pd-composite membranes synthesized by electroless plating technique
    Souleimanova, RS
    Mukasyan, AS
    Varma, A
    JOURNAL OF MEMBRANE SCIENCE, 2000, 166 (02) : 249 - 257
  • [7] Preparation and characterization of Pd-Ag alloy membranes via simultaneous plating by continuous addition of Ag to the electroless plating solution
    Pacheco Tanaka, D. A.
    Fernandez, E.
    Zuniga, J.
    Etxeberria, M.
    Miguel, S.
    Corengia, P.
    EUROMEMBRANE CONFERENCE 2012, 2012, 44 : 1002 - 1004
  • [8] Alloying and surface composition of model Pd-Ag films synthesized by electroless deposition
    Tarditi, A. M.
    Bosko, M. L.
    Cornaglia, L. M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (07) : 6020 - 6029
  • [9] Improving the control of the electroless plating synthesis of Pd/Ag membranes for hydrogen separation using Rutherford backscattering
    Witjens, LC
    Bitter, JH
    van Dillen, AJ
    Arnoldbik, WM
    Habraken, FHPM
    de Jong, KP
    JOURNAL OF MEMBRANE SCIENCE, 2005, 254 (1-2) : 241 - 248
  • [10] Characterization of Pd-Ag membranes fabricated by surfactant induced electroless plating (SIEP) for hydrogen separation
    Moniruddin, Md
    Billups, Tanisha
    Deshmane, Vishwanath
    Rahman, Md M.
    Ilias, Shamsuddin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248