Transthoracic echocardiographic and cardiopulmonary exercise testing parameters in Eisenmenger's syndrome Association with six-minute walk test distance

被引:4
作者
Gungor, H. [1 ]
Ayik, M. Fatih [2 ]
Engin, C. [2 ]
Yagdi, T. [2 ]
Atay, Y. [2 ]
Ozbaran, M. [2 ]
Nalbantgil, S. [3 ]
机构
[1] Adnan Menderes Univ, Dept Cardiol, TR-09100 Aydin, Turkey
[2] Ege Univ, Dept Cardiovasc Surg, Izmir, Turkey
[3] Ege Univ, Dept Cardiol, Izmir, Turkey
关键词
Cardiopulmonary exercise testing; Six-minute walk test; Systolic pulmonary artery pressure; Eisenmenger's syndrome; Correlation; PULMONARY-HYPERTENSION; OXYGEN-UPTAKE; PROSTACYCLIN; EPOPROSTENOL; CAPACITY;
D O I
10.1007/s00059-013-3880-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The six-minute walk test (6MWT) evaluates the functional exercise capacity in patients with cardiopulmonary disease. We aimed to investigate the association between 6MWT distance and transthoracic echocardiographic (TTE) findings as well as cardiopulmonary exercise testing (CPET) parameters in Eisenmenger's syndrome (ES) patients waiting for heart-lung transplantation on their initial admission to our center. A total of 23 patients with ES (12 women, 11 men; mean age, 28.2 +/- 8.1 years) were included in the study. The correlation between 6MWT distance and CPET and TTE findings was retrospectively analyzed. The most frequent underlying heart diseases were ventricular septal defect (VSD) with complex congenital heart disease (n = 10, 43 %) and isolated VSD (n = 7, 30 %). The 6MWT distance was 349.7 +/- 77.4 m in the study group. An inverse correlation was found between 6MWT distance and systolic pulmonary arterial pressure (SPAP) measured with TTE (r = -aEuro parts per thousand 0.445; p = 0.03). All patients underwent CPET at the first visit. Mean VO2 max was 14.9 +/- 3.3 ml/kg/min and the VE/VCO2 rate was 50.4 +/- 9.2 %. No significant correlation was observed between 6MWT and CPET findings. SPAP, which did not display any correlation with CPET findings, was the only independent predictor of 6MWT distance. We suggest that 6MWT distance may be more suitable than CPET in the follow-up of ES patients. Further prospective, randomized, controlled trials are necessary to make more robust interpretations of this issue.
引用
收藏
页码:633 / 637
页数:5
相关论文
共 18 条
[2]   A comparison of continuous intravenous epoprostenol (prostacyclin) with conventional therapy for primary pulmonary hypertension [J].
Barst, RJ ;
Rubin, LJ ;
Long, WA ;
McGoon, MD ;
Rich, S ;
Badesch, DB ;
Groves, BM ;
Tapson, VF ;
Bourge, RC ;
Brundage, BH ;
Koerner, SK ;
Langleben, D ;
Keller, CA ;
Murali, S ;
Uretsky, BF ;
Clayton, LM ;
Jobsis, MM ;
Blackburn, SD ;
Shortino, D ;
Crow, JW .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (05) :296-301
[3]   The six-minute walk test predicts peak oxygen uptake and survival in patients with advanced heart failure [J].
Cahalin, LP ;
Mathier, MA ;
Semigran, MJ ;
Dec, GW ;
DiSalvo, TG .
CHEST, 1996, 110 (02) :325-332
[4]   Six minute walk distance in healthy subjects aged 55-75 years [J].
Camarri, B ;
Eastwood, PR ;
Cecins, NM ;
Thompson, PJ ;
Jenkins, S .
RESPIRATORY MEDICINE, 2006, 100 (04) :658-665
[5]   ATS statement: Guidelines for the six-minute walk test [J].
Crapo, RO ;
Casaburi, R ;
Coates, AL ;
Enright, PL ;
MacIntyre, NR ;
McKay, RT ;
Johnson, D ;
Wanger, JS ;
Zeballos, RJ ;
Bittner, V ;
Mottram, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) :111-117
[6]  
Demir R, 2010, TURK KARDIYOL DERN A, V38, P580
[7]  
Eisenmenger V., 1897, ZEITSCHR KLIN MED, V32S, P1
[8]   Reference equations for the six-minute walk in healthy adults [J].
Enright, PL ;
Sherrill, DL .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (05) :1384-1387
[9]   Assessment of oxygen uptake during the 6-minute walking test in patients with heart failure: Preliminary experience with a portable device [J].
Faggiano, P ;
DAloia, A ;
Gualeni, A ;
Lavatelli, A ;
Giordano, A .
AMERICAN HEART JOURNAL, 1997, 134 (02) :203-206
[10]  
Gibbons W J, 2001, J Cardiopulm Rehabil, V21, P87, DOI 10.1097/00008483-200103000-00005