A method suitable for in vivo measurement of bone strain in humans

被引:39
作者
Hoshaw, SJ
Fyhrie, DP
Takano, Y
Burr, DB
Milgrom, C
机构
[1] HENRY FORD HOSP,CTR BONE & JOINT,DETROIT,MI 48202
[2] INDIANA UNIV,DEPT ANAT & ORTHOPED SURG,INDIANAPOLIS,IN 46202
[3] INDIANA UNIV,BIOMECH & BIOMAT RES CTR,INDIANAPOLIS,IN 46202
[4] HADASSAH UNIV HOSP,DEPT ORTHOPAED,IL-91120 JERUSALEM,ISRAEL
关键词
strain gage; human cortical bone; PMMA;
D O I
10.1016/S0021-9290(96)00176-5
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Strain gages are the gold-standard for measurement of bone strains iii vivo. The use of strain gages in humans, however, is limited by the need for surgery to implant them and by the use of cyanoacrylate adhesives to bond them to bone. Cyanoacryrate adhesives are not FDA approved for implantation in humans, making it difficult to justify their use in experimental procedures. To surmount this difficulty, a method was developed to bond strain gages to bone using an approved substance:polymethylmethacrylate (PMMA). The technique and the validating experiments are presented. The PMMA bonding method gave strain gage readings within an average of 0.25% (range 0-5%) of those found using cyanoacrylate bonding in a side by side comparison on cast acrylic. On bone, the PMMA bonding method produced results comparable to extensometer readings. This method of strain gage application is accurate and straightforward. It is currently being successfully used for in vivo strain measurements in both humans and animals for up to several days following gage application. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:521 / 524
页数:4
相关论文
共 13 条
[1]   In vivo measurement of human tibial strains during vigorous activity [J].
Burr, DB ;
Milgrom, C ;
Fyhrie, D ;
Forwood, M ;
Nyska, M ;
Finestone, A ;
Hoshaw, S ;
Saiag, E ;
Simkin, A .
BONE, 1996, 18 (05) :405-410
[2]   THE EFFECTS OF ALTERED STRAIN ENVIRONMENTS ON BONE TISSUE KINETICS [J].
BURR, DB ;
SCHAFFLER, MB ;
YANG, KH ;
WU, DD ;
LUKOSCHEK, M ;
KANDZARI, D ;
SIVANERI, N ;
BLAHA, JD ;
RADIN, EL .
BONE, 1989, 10 (03) :215-221
[3]  
BURR DB, 1995, UNPUB
[4]  
CARTER DR, 1982, CRIT REV BIOMED ENG, V8, P1
[5]   MEASUREMENT AND ANALYSIS OF INVIVO BONE STRAINS ON THE CANINE RADIUS AND ULNA [J].
CARTER, DR ;
SMITH, DJ ;
SPENGLER, DM ;
DALY, CH ;
FRANKEL, VH .
JOURNAL OF BIOMECHANICS, 1980, 13 (01) :27-&
[6]   IMPLANTATION OF STRAIN GAGES ON BONE IN-VIVO [J].
COCHRAN, GVB .
JOURNAL OF BIOMECHANICS, 1972, 5 (01) :119-&
[7]   CHARACTERIZING BONE STRAIN DISTRIBUTIONS INVIVO USING 3 TRIPLE ROSETTE STRAIN-GAUGES [J].
GROSS, TS ;
MCLEOD, KJ ;
RUBIN, CT .
JOURNAL OF BIOMECHANICS, 1992, 25 (09) :1081-1087
[8]   BONE DEFORMATION RECORDED INVIVO FROM STRAIN GAUGES ATTACHED TO HUMAN TIBIAL SHAFT [J].
LANYON, LE ;
HAMPSON, WGJ ;
GOODSHIP, AE ;
SHAH, JS .
ACTA ORTHOPAEDICA SCANDINAVICA, 1975, 46 (02) :256-268
[9]   IN-VIVO BONE STRAIN RECORDED FROM THORACIC VERTEBRAE OF SHEEP [J].
LANYON, LE .
JOURNAL OF BIOMECHANICS, 1972, 5 (03) :277-&
[10]   INFLUENCE OF MECHANICAL FUNCTION ON THE DEVELOPMENT AND REMODELING OF THE TIBIA - EXPERIMENTAL-STUDY IN SHEEP [J].
LANYON, LE ;
BOURN, S .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (02) :263-273