Cherenkov-light imaging of induced positron distribution in liquid water after proton beam irradiation

被引:0
|
作者
Yamamoto, Seiichi [1 ]
Yamashita, Tomohiro [2 ]
Kobashi, Yusuke [2 ]
Hirano, Yoshiyuki [3 ]
Akagi, Takashi [4 ]
Yokokawa, Hiromu [1 ]
Kataoka, Jun [1 ]
机构
[1] Waseda Univ, Fac Sci & Engn, Tokyo 1698555, Japan
[2] Kobe Proton Ctr, Kobe, Hyogo 6500046, Japan
[3] Nagoya Univ, Dept Integrated Hlth Sci, Grad Sch Med, Nagoya, Aichi 4618673, Japan
[4] Hyogo Ion Beam Med Ctr, Tatsuno 6795165, Japan
关键词
Cherenkov detectors; Instrumentation for hadron therapy; Instrumentation for particlebeam therapy; Radiotherapy concepts; PROMPT GAMMA-RAYS; RANGE VERIFICATION; EMISSION-TOMOGRAPHY; CAMERA; DELIVERY;
D O I
10.1088/1748-0221/17/11/P11043
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Imaging of positrons induced by nuclear reactions with a proton beam is a possible method for observing the beam shape from outside the subject. However, such imaging of induced positrons has so far been conducted for solid materials. The induced positron distribution in liquid water has not been measured or reported. To clarify the distribution of induced positrons in liquid water, we conducted Cherenkov-light imaging after irradiation by protons to a water phantom. After irradiation by a 117-MeV proton beam to a phantom containing liquid water, Cherenkov-light imaging of the induced positrons was conducted using a cooled charge-coupled device (CCD) camera following the decay of the positrons. We also imaged the luminescence of water during irradiation by the proton beam to compare the distributions. We could measure the distribution of Cherenkov-light from the induced positrons in liquid water. Positron distributions kept their beam shapes in water but were different from that of the luminescence image; positron distribution was wider in the deep area of the beams in the lateral as well as depth direction. The distributions' shapes were only slightly changed with time. We conclude that Cherenkov-light imaging from the induced positrons after irradiation by a proton beam in water was possible, and we found that the induced positrons kept their beam shape in water with different shape from that of dose. These findings may provide new insights for imaging in particle therapy.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] High resolution Cerenkov light imaging of induced positron distribution in proton therapy
    Yamamoto, Seiichi
    Toshito, Toshiyuki
    Fujii, Kento
    Morishita, Yuki
    Okumura, Satoshi
    Komori, Masataka
    MEDICAL PHYSICS, 2014, 41 (11)
  • [2] Luminescence imaging of water during proton-beam irradiation for range estimation
    Yamamoto, Seiichi
    Toshito, Toshiyuki
    Okumura, Satoshi
    Komori, Masataka
    MEDICAL PHYSICS, 2015, 42 (11) : 6498 - 6506
  • [3] A triple-imaging-modality system for simultaneous measurements of prompt gamma photons, prompt x-rays, and induced positrons during proton beam irradiation
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Nakanishi, Kohei
    Yabe, Takuya
    Yamaguchi, Mitsutaka
    Kawachi, Naoki
    Kamada, Kei
    Yoshikawa, Akira
    Miyake, Masayasu
    Tanaka, Kazuo S.
    Kataoka, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (05)
  • [4] Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing 12C, 16O, and 40Ca nuclei in preparation of clinical application
    Miyatake, Aya
    Nishio, Teiji
    Ogino, Takashi
    MEDICAL PHYSICS, 2011, 38 (10) : 5818 - 5829