Wind-tunnel analysis of natural ventilation in a generic building in sheltered and unsheltered conditions: Impact of Reynolds number and wind direction

被引:24
|
作者
Golubic, Dino [1 ,2 ]
Meile, Walter [2 ]
Brenn, Guenter [2 ]
Kozmar, Hrvoje [1 ]
机构
[1] Univ Zagreb, Fac Mech Engn & Naval Architecture, Ivana Lucica 5, Zagreb 10000, Croatia
[2] Graz Univ Technol, Inst Fluid Mech & Heat Transfer, Inffeldgasse 25-F, A-8010 Graz, Austria
关键词
Generic building; Suburban terrain; Flow velocity and direction; Cross- and single-sided ventilation; Unsheltered and sheltered conditions; Spacing density of buildings; Wind-tunnel experiments; CROSS-VENTILATION; FULL-SCALE; AIR-FLOW; CFD SIMULATION; BUOYANCY; DRIVEN; PRESSURES; ENCLOSURE; DESIGN; MODEL;
D O I
10.1016/j.jweia.2020.104388
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is generally preferred to mechanical ventilation because it saves energy and protects the outdoor atmospheric environment. The present work focuses on the air change rate (ACH) of a generic building for single-sided and cross-ventilation arrangements. This topic was studied on small-scale building models of cubic shape in a boundary layer wind tunnel. Experiments were carried out by simulating the atmospheric boundary layer (ABL) over suburban terrain that impinges a building model standing alone or surrounded by other buildings in a symmetrical 3 x 3 pattern. The spacing density of building models, flow incidence angle, velocity, and ventilation arrangement were major parameters for quantifying the ventilation performance. Hot-wire anemometry was used to determine the flow characteristics, and a tracer gas system was applied to measure the ACH. The ACH obtained for the isolated building proved larger than for the sheltered case, as expected. In the latter case, the ventilation is more efficient for less densely spaced buildings. For the isolated building, a linear relationship between the ACH and the flow velocity can be justified for both ventilation types. For the cross-ventilation setup, a model equation is proposed. It quantifies the dependence of the ACH on the flow velocity and incidence angle.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Experimental study on cross-ventilation of a generic building in highly-dense urban areas: Impact of planar area density and wind direction
    Shirzadi, Mohammadreza
    Tominaga, Yoshihide
    Mirzaei, Parham A.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2020, 196 (196)
  • [42] Stochastic Numerical Analysis on Aerodynamic Characteristics of Low Reynolds Number Wind Turbine Airfoil under Natural Wind Speed
    Tang X.
    Yuan K.
    Wang X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (02): : 45 - 52
  • [43] CFD prediction of the natural ventilation in a tunnel-type greenhouse: Influence of wind direction and sensibility to turbulence models
    Roy, JC
    Boulard, T
    Proceedings of the International Conference on Sustainable Greenhouse Systems, Vols 1 and 2, 2005, (691): : 457 - 464
  • [44] Reynolds number and wind tunnel wall effects on the flow field around a generic UHBR engine high-lift configuration
    Ullah J.
    Prachař A.
    Šmíd M.
    Seifert A.
    Soudakov V.
    Lutz T.
    Krämer E.
    CEAS Aeronautical Journal, 2020, 11 (04) : 1009 - 1023
  • [45] CFD simulation of natural ventilation of a generic building in various incident wind directions: Comparison of turbulence modelling, evaluation methods, and ventilation mechanisms
    Zhang, Xuelin
    Weerasuriya, A. U.
    Tse, K. T.
    ENERGY AND BUILDINGS, 2020, 229 (229)
  • [46] Wind-tunnel analysis of turbulent flow in cross-ventilated buildings with windcatchers: Impact of surrounding buildings
    Zaki, Ahmad
    Sharma, Rajnish
    BUILDING AND ENVIRONMENT, 2023, 244
  • [47] CFD and wind-tunnel analysis of outdoor ventilation in a real compact heterogeneous urban area: Evaluation using "air delay"
    Antoniou, Nestoras
    Montazeri, Hamid
    Wigo, Hans
    Neophytou, Marina K. -A.
    Blocken, Bert
    Sandberg, Mats
    BUILDING AND ENVIRONMENT, 2017, 126 : 355 - 372
  • [48] CFD Analysis of an Innovative Wind Tower Design with Wind-Inducing Natural Ventilation Technique for Arid Climatic Conditions
    Obeidat, Bushra
    Kamal, Hammam
    Almalkawi, Amal
    JOURNAL OF ECOLOGICAL ENGINEERING, 2021, 22 (02): : 86 - 97
  • [49] Validity of Orifice equation and impact of building parameters on wind-induced natural ventilation rates with minute mean wind pressure difference
    Jiang, Zitao
    Kobayashi, Tomohiro
    Yamanaka, Toshio
    Sandberg, Mats
    Kobayashi, Noriaki
    Choi, Narae
    Sano, Kayuki
    BUILDING AND ENVIRONMENT, 2022, 219
  • [50] Chained analysis of wind tunnel test and CFD on cross ventilation of large-scale market building
    Kato, S
    Murakami, S
    Takahashi, T
    Gyobu, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 67-8 : 573 - 587