Wind-tunnel analysis of natural ventilation in a generic building in sheltered and unsheltered conditions: Impact of Reynolds number and wind direction

被引:24
|
作者
Golubic, Dino [1 ,2 ]
Meile, Walter [2 ]
Brenn, Guenter [2 ]
Kozmar, Hrvoje [1 ]
机构
[1] Univ Zagreb, Fac Mech Engn & Naval Architecture, Ivana Lucica 5, Zagreb 10000, Croatia
[2] Graz Univ Technol, Inst Fluid Mech & Heat Transfer, Inffeldgasse 25-F, A-8010 Graz, Austria
关键词
Generic building; Suburban terrain; Flow velocity and direction; Cross- and single-sided ventilation; Unsheltered and sheltered conditions; Spacing density of buildings; Wind-tunnel experiments; CROSS-VENTILATION; FULL-SCALE; AIR-FLOW; CFD SIMULATION; BUOYANCY; DRIVEN; PRESSURES; ENCLOSURE; DESIGN; MODEL;
D O I
10.1016/j.jweia.2020.104388
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Natural ventilation is generally preferred to mechanical ventilation because it saves energy and protects the outdoor atmospheric environment. The present work focuses on the air change rate (ACH) of a generic building for single-sided and cross-ventilation arrangements. This topic was studied on small-scale building models of cubic shape in a boundary layer wind tunnel. Experiments were carried out by simulating the atmospheric boundary layer (ABL) over suburban terrain that impinges a building model standing alone or surrounded by other buildings in a symmetrical 3 x 3 pattern. The spacing density of building models, flow incidence angle, velocity, and ventilation arrangement were major parameters for quantifying the ventilation performance. Hot-wire anemometry was used to determine the flow characteristics, and a tracer gas system was applied to measure the ACH. The ACH obtained for the isolated building proved larger than for the sheltered case, as expected. In the latter case, the ventilation is more efficient for less densely spaced buildings. For the isolated building, a linear relationship between the ACH and the flow velocity can be justified for both ventilation types. For the cross-ventilation setup, a model equation is proposed. It quantifies the dependence of the ACH on the flow velocity and incidence angle.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Along- and cross-wind response of a generic tall building: Comparison of wind-tunnel data with codes and standards
    Holmes, John D.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2014, 132 : 136 - 141
  • [22] Studies on critical Reynolds number indices for wind-tunnel experiments on flow within urban areas
    Kiyoshi Uehara
    Shinji Wakamatsu
    Ryozo Ooka
    Boundary-Layer Meteorology, 2003, 107 : 353 - 370
  • [23] Wind tunnel investigation of autorotation of plate: The effects of geometry, Reynolds number and rotation direction
    Huang, Peng
    Lin, Huatan
    Gu, Ming
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2020, 196
  • [24] Studies on critical Reynolds number indices for wind-tunnel experiments on flow within urban areas
    Uehara, K
    Wakamatsu, S
    Ooka, R
    BOUNDARY-LAYER METEOROLOGY, 2003, 107 (02) : 353 - 370
  • [25] Numerical simulation and wind tunnel experiments on wind-induced natural ventilation in isolated building with patio
    Driss, Slah
    Driss, Zied
    Kammoun, Imen Kallel
    ENERGY, 2015, 90 : 917 - 925
  • [26] THE APPLICATION OF CRYOGENICS TO HIGH REYNOLDS-NUMBER TESTING IN WIND TUNNELS .2. DEVELOPMENT AND APPLICATION OF THE CRYOGENIC WIND-TUNNEL CONCEPT
    KILGORE, RA
    DRESS, DA
    CRYOGENICS, 1984, 24 (09) : 484 - 493
  • [27] SURFACE-ROUGHNESS STUDIES FOR WIND-TUNNEL MODELS USED IN HIGH REYNOLDS-NUMBER TESTING
    VORBURGER, TV
    MCLAY, MJ
    SCIRE, FE
    GILSINN, DE
    GIAUQUE, CHW
    TEAGUE, EC
    JOURNAL OF AIRCRAFT, 1986, 23 (01): : 56 - 61
  • [28] Estimation model for natural ventilation by wind force considering wind direction and building orientation for low-rise building in China
    Wang, Tian-Wen
    Yin, Wei
    Fu, Lin-Li
    Zhang, Zhi-Yi
    INDOOR AND BUILT ENVIRONMENT, 2022, 31 (08) : 2036 - 2052
  • [29] Wind-tunnel experiments on cross-ventilative cooling in a generic isolated building with one heated wall: Impact of opening size
    Kosutova, Katarina
    Vanderwel, Christina
    van Hooff, Twan
    Blocken, Bert
    Hensen, Jan L. M.
    BUILDING AND ENVIRONMENT, 2024, 259
  • [30] Wind-driven natural ventilation in a low-rise building: A Boundary Layer Wind Tunnel study
    Tecle, Amanuel
    Bitsuamlak, Girma T.
    Jiru, Teshome E.
    BUILDING AND ENVIRONMENT, 2013, 59 : 275 - 289