Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer

被引:30
作者
Huang, Chih-Chung [1 ]
Chen, Ruimin [2 ]
Tsui, Po-Hsiang [3 ]
Zhou, Qifa [2 ]
Humayun, Mark S. [4 ]
Shung, K. Kirk [2 ]
机构
[1] Fu Jen Catholic Univ, Dept Elect Engn, Taipei 24205, Taiwan
[2] Univ So Calif, NIH Resource Med Ultrason Transducer Technol, Dept Biomed Engn, Los Angeles, CA 90089 USA
[3] Acad Sinica, Div Mech, Res Ctr Appl Sci, Taipei 11529, Taiwan
[4] Univ So Calif, Keck Sch Med, Doheny Eye Inst, Doheny Retina Inst,Dept Ophthalmol, Los Angeles, CA 90033 USA
关键词
IN-VITRO; VELOCITY; EYE;
D O I
10.1088/0031-9155/54/19/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A cataract is a clouding of the lens in the eye that affects vision. Phacoemulsification is the mostly common surgical method for treating cataracts, and determining that the optimal phacoemulsification energy is dependent on measuring the hardness of the lens. This study explored the use of an ultrasound needle transducer for invasive measurements of ultrasound attenuation coefficient to evaluate the hardness of the cataract lens. A 47 MHz high-frequency needle transducer with a diameter of 0.9 mm was fabricated by a polarized PMN-33% PT single crystal in the present study. The attenuation coefficients at different stages of an artificial porcine cataract lens were measured using the spectral shift approach. The hardness of the cataract lens was also evaluated by mechanical measurement of its elastic properties. The results demonstrated that the ultrasonic attenuation coefficient was increased from 0.048 +/- 0.02 to 0.520 +/- 0.06 dB mm(-1) MHz(-1) corresponding to an increase in Young's modulus from 6 +/- 0.4 to 96 +/- 6.2 kPa as the cataract further developed. In order to evaluate the feasibility of combining needle transducer and phacoemulsification probe for real-time measurement during cataract surgery, the needle transducer was mounted on the phacoemulsification probe for a vibration test. The results indicated that there was no apparent damage to the tip of the needle transducer and the pulse-echo test showed that a good performance in sensitivity was maintained after the vibration test.
引用
收藏
页码:5981 / 5994
页数:14
相关论文
共 22 条
  • [21] Feasibility study of using high-frequency ultrasonic Nakagami imaging for characterizing the cataract lens in vitro
    Tsui, Po-Hsiang
    Huang, Chih-Chung
    Chang, Chien-Cheng
    Wang, Shyh-Hau
    Shung, K. Kirk
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (21) : 6413 - 6425
  • [22] Wilson M., 2005, PEDIAT CATARACT SURG