On scatter in megavoltage x-ray transmission imaging (in English)

被引:0
作者
Spies, L [1 ]
机构
[1] Deutsch Krebsforschungszentrum, Abt Med Phys, D-69120 Heidelberg, Germany
关键词
D O I
10.1118/1.598905
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This thesis considers the role of scatter in electronic portal imaging devices (EPIDs). The thesis involved a direct measurement of scatter in an EPID. An already established Monte Carlo code, developed at the Royal Marsden Hospital, Sutton/UK, was extended and agreed with the experimental data for phantom-to-detector distances larger than 10 cm. An analytical scatter model was developed on the basis of the Monte Carlo analysis. In this model scatter was estimated by convolving the input beam profile with an analytical scatter kernel. The model was tested over a wide range of clinical parameters. For a 6 MV x-ray beam impinging upon a water-equivalent phantom, the absolute error in the scatter-to-primary ratio was better than 1% for a 100 [formula omitted] field. The accuracy dropped to 4% for a 400 [formula omitted] field. The model was implemented for a camera-based EPID with a converter comprising a 1-mm-thick copper plate bonded to a 134 [formula omitted] phosphor foil. Algorithms were developed for correcting for scatter contributions in megavoltage CT (MVCT) and for reconstruction of input beam profiles. For the latter an overall accuracy of better than 4% was obtained for fields of 100 [formula omitted] in size. In MVCT the yield in contrast resolution after a scatter correction was small. However, a scatter correction reduced the discrepancy of 30% between true and reconstructed electron densities to 10%. In both applications the limit in accuracy is a direct consequence of the performance of the converter, which strongly overestimates multiply scattered photons of low energy. Within the framework of a convolution model multiply scattered radiation exiting an inhomogeneous phantom cannot be calculated with an accuracy exceeding the limits given. © 2000, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:624 / 624
页数:1
相关论文
共 50 条
[21]   X-RAY IMAGING WITH COMPTON-SCATTER RADIATION. [J].
Harding, G. ;
Strecker, H. ;
Tischler, R. .
Philips Technical Review, 1983, 41 (02) :46-59
[22]   The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review [J].
Sayed, Mohammad ;
Knapp, Karen M. ;
Fulford, Jon ;
Heales, Christine ;
Alqahtani, Saeed J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
[23]   Combined imaging system for X-ray fluorescence and transmission X-ray microtomography [J].
Ohigashi, T ;
Watanabe, N ;
Yokosuka, H ;
Aoki, S .
SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 :1352-1355
[24]   X-RAY COMPTON SCATTER IMAGING USING A HIGH-SPEED FLYING SPOT X-RAY TUBE [J].
TOWE, BC ;
JACOBS, AM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (10) :717-721
[25]   Micro-Tomography of Coherent X-ray Scatter Using an X-ray Collimator and Spectral Imaging Array [J].
Eaker, Diane R. ;
Jorgensen, Steven M. ;
Cui, Congwu ;
Ritman, Erik L. .
TOMOGRAPHY AND INVERSE TRANSPORT THEORY, 2011, 559 :171-180
[26]   A new x-ray scatter rejection method based on frequency division multiplexing x-ray imaging technique [J].
Zhang, J. ;
Chang, S. ;
Lu, J. P. ;
Zhou, O. .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[27]   The effects of compensator and imaging geometry on the distribution of x-ray scatter in CBCT [J].
Bootsma, G. J. ;
Verhaegen, F. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2011, 38 (02) :897-914
[28]   X-ray scatter correction algorithm for cone beam CT imaging [J].
Ning, R ;
Tang, XY ;
Conover, D .
MEDICAL PHYSICS, 2004, 31 (05) :1195-1202
[29]   A semianalytic model to investigate the potential applications of x-ray scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 1998, 25 (06) :1008-1020
[30]   Optimum momentum transfer arguments for x-ray forward scatter imaging [J].
Leclair, RJ ;
Johns, PC .
MEDICAL PHYSICS, 2002, 29 (12) :2881-2890