Determination of the compressor optimal working conditions

被引:35
作者
Aprea, C. [1 ]
Mastrullo, R. [2 ]
Renno, C. [1 ]
机构
[1] Univ Salerno, Dept Mech Engn, I-84084 Salerno, Italy
[2] Univ Naples Federico 2, DETEC, I-80125 Naples, Italy
关键词
Scroll and reciprocating compressor; Optimum frequency; Energy saving; Exergy and economy aspects; SPEED; PERFORMANCE;
D O I
10.1016/j.applthermaleng.2008.10.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
The replacement of environmentally unfriendly refrigerants and the energy saving demand have recently caused changes of the components and operation of the vapour compression plants; in particular, the compressors have been experiencing upgrades and modifications. The compression systems are usually designed for working under maximum load conditions, but most of the time these plants work under partial load conditions with compressor on-off cycles regulated by a thermostat. As for the variable speed compressor, the speed is continuously controlled to match the compressor capacity to the load required; this allows to save energy when compared to the thermostatic control. The aim of this paper is to identify the compressor current frequency that optimizes the energy, exergy and economy aspects. The determination of the optimum frequency for each working condition is key to build a control algorithm that allows the compressor speed to be continuously regulated by an inverter. This analysis has been applied to the reciprocating and scroll compressors and high energy savings have been achieved, (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1991 / 1997
页数:7
相关论文
共 9 条
[1]   Fuzzy control of the compressor speed in a refrigeration plant [J].
Aprea, C ;
Mastrullo, R ;
Renno, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (06) :639-648
[2]  
CHENG HS, 2005, ENERG CONVERS MANAGE, V46, P373
[3]   Influence of liquid refrigerant injection on the performance of an inverter-driven scroll compressor [J].
Cho, H ;
Chung, JT ;
Kim, Y .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (01) :87-94
[4]  
Dabiri A.E., 1981, ASHRAE T, V87, P771
[5]  
Kotas TJ., 1995, The exergy method of thermal plant analysis
[6]   Numerical simulation of a variable speed refrigeration system [J].
Koury, RNN ;
Machado, L ;
Ismail, KAR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (02) :192-200
[7]  
MICHAEL MC, 2007, INT J REFRIGER, V30, P912
[8]   Design optimization of a rolling piston compressor for refrigerators [J].
Ooi, KT .
APPLIED THERMAL ENGINEERING, 2005, 25 (5-6) :813-829
[9]   Performance representation of variable-speed compressor for inverter air conditioners based on experimental data [J].
Shao, SQ ;
Shi, WX ;
Li, XT ;
Chen, HJ .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08) :805-815