Temperature control design for a high-resolution gamma-ray tomography detector

被引:16
作者
Bieberle, Andre [1 ]
Schleicher, Eckhard [1 ]
Hampel, Uwe [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf, Inst Safety Res, D-01328 Dresden, Germany
关键词
computerised tomography; gamma-ray effects; heat transfer; temperature control; BUBBLE-COLUMNS; SCANNER; SYSTEM;
D O I
10.1063/1.3280184
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, a thermal control design for a high-resolution gamma-ray computed tomography detector is presented. It accounts for the generation of heat produced by active electronic components as well as heat transfer from external heat sources. The development and implementation of this feature were motivated by stringent requirements for measurement accuracy at thermal hydraulic test facilities, where ambient thermal conditions are constantly changing. As a first step, the thermal behavior of the existing tomography detector was analyzed, critical components were identified, and different approaches for heat removal were tested. Eventually, an improved thermal detector design was elaborated and a controlled active cooling system was implemented. Performance tests proved its effectiveness and accuracy improvement.
引用
收藏
页数:7
相关论文
共 18 条
[1]   Data acquisition system for angle synchronized γ-ray tomography of rapidly rotating objects [J].
Bieberle, A. ;
Schleicher, E. ;
Hampel, U. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) :3384-3390
[2]   Design of a high-resolution gamma-ray detector module for tomography applications [J].
Bieberle, A. ;
Kronenberg, J. ;
Schleicher, E. ;
Hampel, U. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (02) :668-675
[3]  
Bieberle A, 2006, ATW-INT J NUCL POWER, V51, P539
[4]  
De Vuono C., 1980, IEEE T NUCL SCI, V27, P814, DOI DOI 10.1109/TNS.1980.4330933
[5]  
GILBOY WB, 1982, NUCL INSTRUM METHODS, V193, P209, DOI 10.1016/0029-554X(82)90698-X
[6]   ALGEBRAIC RECONSTRUCTION TECHNIQUES (ART) FOR 3-DIMENSIONAL ELECTRON MICROSCOPY AND X-RAY PHOTOGRAPHY [J].
GORDON, R ;
BENDER, R ;
HERMAN, GT .
JOURNAL OF THEORETICAL BIOLOGY, 1970, 29 (03) :471-&
[7]  
Graeme J., 1996, ser. Gain technology
[8]   High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications [J].
Hampel, U. ;
Bieberle, A. ;
Hoppe, D. ;
Kronenberg, J. ;
Schleicher, E. ;
Suehnel, T. ;
Zimmermann, F. ;
Zippe, C. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10)
[9]   Application of high-resolution gamma ray tomography to the measurement of gas hold-up distributions in a stirred chemical reactor [J].
Hampel, U. ;
Hristov, H. V. ;
Bieberle, A. ;
Zippe, C. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2007, 18 (5-6) :184-190
[10]   A dual sensor flow imaging tomographic system [J].
Johansen, GA ;
Froystein, T ;
Hjertaker, BT ;
Olsen, O .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (03) :297-307