The Woven Endobridge Device for Treatment of Intracranial Aneurysms: A Systematic Review

被引:25
作者
Muskens, Ivo S. [1 ,2 ]
Senders, Joeky T. [1 ,2 ]
Dasenbrock, Hormuzdiyar H. [2 ]
Smith, Timothy R. S. [2 ]
Broekman, Marike L. D. [1 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Neurosurg, Utrecht, Netherlands
[2] Brigham & Womens Hosp, Harvard Med Sch, Cushing Neurosurg Outcomes Ctr, Dept Neurosurg, Boston, MA USA
[3] Massachusetts Gen Hosp, Dept Neurosurg, Boston, MA USA
关键词
Endovascular treatment; Intracranial aneurysm; WEB device; ENDOVASCULAR TREATMENT; WEB DEVICE; EMBOLIZATION DEVICE; FLOW DISRUPTION; COILING; TRIAL; MULTICENTER; COMPLICATIONS; FEASIBILITY; ISAT;
D O I
10.1016/j.wneu.2016.11.020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
INTRODUCTION: The Woven Endobridge (WEB) device is an innovative endovascular device for treatment of intracranial aneurysms, especially bifurcation and wide-neck aneurysms. Although not approved by the U.S. Food and Drug Administration, it has been available in Europe since 2011. The aim of this review is to evaluate the outcomes of WEB device use for intracranial aneurysm treatment. METHODS: A systematic review was conducted with MEDLINE search engines PubMed and Embase from 2011. The search strategy provided 6229 articles, and 19 articles were included. RESULTS: A total of 19 papers were identified describing the use of WEB devices in 687 patients with 718 aneurysms. The 2 largest prospective multi-center studies (WEBCAST and the French Observatory Trial) reported successful treatment, defined as complete closure or a neck remnant, in 85% and 79% of aneurysms, respectively. The use of a WEB device in combination with coiling or stenting was described with varying results in multiple small series. Outcomes of WEB device use in ruptured aneurysms in 2 studies showed 94% and 80% adequate treatment. Thromboembolic events were described in 71 patients (10.3% of all patients) and infarctions in 8 patients (1.2% of all patients). CONCLUSIONS: Despite initial promising results, the WEB device should be used with caution given its potentially large learning curve and because it has primarily been investigated only in wide-neck and bifurcation aneurysms. In addition, currently available prospective studies have short follow-up, and the device has not been directly compared with other treatment modalities.
引用
收藏
页码:809 / 817
页数:9
相关论文
共 39 条
  • [1] Hospital Mortality and Complications of Electively Clipped or Coiled Unruptured Intracranial Aneurysm
    Alshekhlee, Amer
    Mehta, Sonal
    Edgell, Randall C.
    Vora, Nirav
    Feen, Eli
    Mohammadi, Afshin
    Kale, Sushant P.
    Cruz-Flores, Salvador
    [J]. STROKE, 2010, 41 (07) : 1471 - 1476
  • [2] Endovascular treatment of bifurcation intracranial aneurysms with the WEB SL/SLS: 6-month clinical and angiographic results
    Ambrosi, Patricia Bozzetto
    Gory, Benjamin
    Sivan-Hoffmann, Rotem
    Riva, Roberto
    Signorelli, Francesco
    Labeyrie, Paul-Emile
    Eldesouky, Islam
    Sadeh-Gonike, Udi
    Armoiry, Xavier
    Turjman, Francis
    [J]. INTERVENTIONAL NEURORADIOLOGY, 2015, 21 (04) : 462 - 469
  • [3] WEB in Partially Thrombosed Intracranial Aneurysms: A Word of Caution
    Anil, G.
    Goddard, A. J. P.
    Ross, S. M.
    Deniz, K.
    Patankar, T.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (05) : 892 - 896
  • [4] [Anonymous], J NEUROINTERV SURG
  • [5] [Anonymous], J NEUROINTERV SURG
  • [6] [Anonymous], J NEUROSURG
  • [7] Woven EndoBridge Intrasaccular Flow Disrupter for the Treatment of Ruptured and Unruptured Wide-Neck Cerebral Aneurysms: Report of 55 Cases
    Behme, D.
    Berlis, A.
    Weber, W.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (08) : 1501 - 1506
  • [8] Single-Layer WEBs: lntrasaccular Flow Disrupters for Aneurysm Treatment-Feasibility Results from a European Study
    Caroff, J.
    Mihalea, C.
    Klisch, J.
    Strasilla, C.
    Berlis, A.
    Patankar, T.
    Weber, W.
    Behme, D.
    Jacobsen, E. A.
    Liebig, T.
    Prothmann, S.
    Cognard, C.
    Finkenzeller, T.
    Moret, J.
    Spelle, L.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (10) : 1942 - 1946
  • [9] Woven Endobridge (WEB) Device for endovascular treatment of ruptured intracranial wide-neck aneurysms: a single-center experience
    Caroff, Jildaz
    Mihalea, Cristian
    Dargento, Francesco
    Neki, Hiroaki
    Ikka, Leon
    Benachour, Nidhal
    Moret, Jacques
    Spelle, Laurent
    [J]. NEURORADIOLOGY, 2014, 56 (09) : 755 - 761
  • [10] Treatment of Wide-Neck Basilar Tip Aneurysms Using the Web II Device
    Colla, Ruben
    Cirillo, Luigi
    Princiotta, Ciro
    Dall'olio, Massimo
    Menetti, Federico
    Vallone, Stefano
    Leonardi, Marco
    [J]. NEURORADIOLOGY JOURNAL, 2013, 26 (06) : 669 - 677