Monitoring the production of inclusion bodies during fermentation and enzyme-linked immunosorbent assay analysis of intact inclusion bodies using cryogel minicolumn plates

被引:12
作者
Ahlqvist, Josefin
Dainiak, Maria B.
Kumar, Ashok
Hornsten, E. Gunnar
Galaev, Igor Yu.
Mattiasson, Bo [1 ]
机构
[1] Lund Univ, Ctr Chem & Chem Engn, Dept Biotechnol, SE-22100 Lund, Sweden
[2] Protista Biotechnol AB, SE-22370 Lund, Sweden
[3] Indian Inst Technol, Dept Biol Sci & Bioengn, Kanpur 208016, Uttar Pradesh, India
[4] Sik Swedish Inst Food & Biotechnol, SE-22370 Lund, Sweden
基金
瑞典研究理事会;
关键词
ELISA; surface-expressed antigen; inclusion bodies; fermentation; bioprocess; cryogel adsorbents; protein A- and phenyl-cryogel minicolumn plate; monitoring; antibodies;
D O I
10.1016/j.ab.2006.03.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel minicolumn chromatgraphic method to monitor the production of inclusion bodies during fermentation and anenzyme-linked immunosorbent assay (ELISA) system allowing direct analysis of the particles with surface-displayed antigens are described. A 33-kDa protein containing 306 amino acids with three sulfur bridges produced its inclusion bodies wits labeled with polyclonal antibodies against 15 amino acid (anti-A15) and 17 amino acid (anti-B17) residues at the N- and C-terminal ends of the protein, respectively. Labeled particles were bound to macroporous Monolithic protein A-cryogel adsorbents inserted into the open-ended wells of a 96-well plate (referred to as protein A-cryogel minicolumn plate). The concept behind this application is that the binding degree of inclusion bodies from lysed fermentation broth to the cryogel minicolumns increases with an increase in their concentration during fermentation. The technique allowed LIS to monitor the increase in the production levels of the inclusion bodies as the fermentation process progressed. The system also has a built-in quality parameter to ensure that the target protein has been fully expressed. Alternatively, inclusion bodies immobilized on phenyl-cryogel minicolumn plate were used in indirect ELISA based on anti-A15 and anti-B17 antibodies against terminal amino acid residues displayed oil the surface of inclusion bodies. Drainage-protected properties of the cryogel minicolumns allow performance of successive reactions with tested immunoglobulin G (IgG) samples and enzyme-conjugated secondary I-G and of enzymatic reaction within the adsorbent. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:229 / 237
页数:9
相关论文
共 22 条
  • [1] Affinity binding of inclusion bodies on supermacroporous monolithic cryogels using labeling with specific antibodies
    Ahlqvist, J
    Kumar, A
    Sundström, H
    Ledung, E
    Hörnsten, EG
    Enfors, SO
    Mattiasson, B
    [J]. JOURNAL OF BIOTECHNOLOGY, 2006, 122 (02) : 216 - 225
  • [2] Direct chromatographic capture of enzyme from crude homogenate using immobilized metal affinity chromatography on a continuous supermacroporous adsorbent
    Arvidsson, P
    Plieva, FM
    Lozinsky, VI
    Galaev, IY
    Mattiasson, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (02) : 275 - 290
  • [3] Chromatography of microbial cells using continuous supermacroporous affinity and ion-exchange columns
    Arvidsson, P
    Plieva, FM
    Savina, IN
    Lozinsky, VI
    Fexby, S
    Bülow, L
    Galaev, IY
    Mattiasson, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2002, 977 (01) : 27 - 38
  • [4] Cell chromatography: Separation of different microbial cells using IMAC supermacroporous monolithic columns
    Dainiak, MB
    Plieva, FM
    Galaev, IY
    Hatti-Kaul, R
    Mattiasson, B
    [J]. BIOTECHNOLOGY PROGRESS, 2005, 21 (02) : 644 - 649
  • [5] Integrated isolation of antibody fragments from microbial cell culture fluids using supermacroporous cryogels
    Dainiak, MB
    Kumar, A
    Plieva, FM
    Galaev, IY
    Mattiasson, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) : 93 - 98
  • [6] High throughput processing of particulate-containing samples using supermacroporous elastic monoliths in microtiter (multiwell) plate format
    Galaev, IY
    Dainiak, MB
    Plieva, FM
    Hatti-Kaul, R
    Mattiasson, B
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1065 (02) : 169 - 175
  • [7] A novel ELISA using PVDF microplates
    Halim, ND
    Joseph, AW
    Lipska, BK
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2005, 143 (02) : 163 - 168
  • [8] Kemeny D., 1988, ELISA OTHER SOLID PH, P1
  • [9] Affinity binding of cells to cryogel adsorbents with immobilized specific ligands:: effect of ligand coupling and matrix architecture
    Kumar, A
    Rodríguez-Caballero, A
    Plieva, FM
    Galaev, IY
    Nandakumar, KS
    Kamihira, M
    Holmdahl, R
    Orfao, A
    Mattiasson, B
    [J]. JOURNAL OF MOLECULAR RECOGNITION, 2005, 18 (01) : 84 - 93
  • [10] Affinity fractionation of lymphocytes using a monolithic cryogel
    Kumar, A
    Plieva, FM
    Galeav, IY
    Mattiasson, B
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 283 (1-2) : 185 - 194