Tissue-engineered intervertebral discs: MRI results and histology in the rodent spine Presented at the 2013 Spine Section Meeting Laboratory investigation

被引:17
作者
Grunert, Peter [1 ]
Gebhard, Harry H. [1 ]
Bowles, Robby D. [2 ]
James, Andrew R. [1 ]
Potter, Hollis G. [3 ]
Macielak, Michael [1 ]
Hudson, Katherine D. [2 ]
Alimi, Marjan [1 ]
Ballon, Douglas J. [4 ]
Aronowitz, Eric [4 ]
Tsiouris, Apostolos John [4 ]
Bonassar, Lawrence J. [2 ,5 ]
Haertl, Roger [1 ]
机构
[1] NewYork Presbyterian Hosp, Weill Cornell Med Coll, Dept Neurol Surg, Weill Cornell Brain & Spine Inst, New York, NY 10065 USA
[2] Cornell Univ, Dept Biomed Engn, Ithaca, NY USA
[3] Hosp Special Surg, Dept Radiol, New York, NY 10021 USA
[4] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY USA
关键词
tissue engineering; intervertebral disc; rat-tail model; intervertebral disc disease; disc degeneration; NUCLEUS PULPOSUS; ANNULUS FIBROSUS; PROTEOGLYCAN CONTENT; MOTION PRESERVATION; RELAXATION-TIMES; ANULUS FIBROSUS; IN-VITRO; DEGENERATION; EPIDEMIOLOGY; NUTRITION;
D O I
10.3171/2013.12.SPINE13112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Tissue-engineered intervertebral discs (TE-IVDs) represent a new experimental approach for the treatment of degenerative disc disease. Compared with mechanical implants, TE-IVDs may better mimic the properties of native discs. The authors conducted a study to evaluate the outcome of TE-IVDs implanted into the rat-tail spine using radiological parameters and histology. Methods. Tissue-engineered intervertebral discs consist of a distinct nucleus pulposus (NP) and anulus fibrosus (AF) that are engineered in vitro from sheep IVD chondrocytes. In 10 athymic rats a discectomy in the caudal spine was performed. The discs were replaced with TE-IVDs. Animals were kept alive for 8 months and were killed for histological evaluation. At 1,5, and 8 months, MR images were obtained; T1-weighted sequences were used for disc height measurements, and T2-weighted sequences were used for morphological analysis. Quantitative T2 relaxation time analysis was used to assess the water content and Tip-relaxation time to assess the proteoglycan content of TE-IVDs. Results. Disc height of the transplanted segments remained constant between 68% and 74% of healthy discs. Examination of TE-IVDs on MR images revealed morphology similar to that of native discs. T2-relaxation time did not differ between implanted and healthy discs, indicating similar water content of the NP tissue. The size of the NP decreased in TE-IVDs. Proteoglycan content in the NP was lower than it was in control discs. Ossification of the implanted segment was not observed. Histological examination revealed an AF consisting of an organized parallel-aligned fiber structure. The NP matrix appeared amorphous and contained cells that resembled chondrocytes. Conclusions. The TB-IVDs remained viable over 8 months in vivo and maintained a structure similar to that of native discs. Tissue-engineered intervertebral discs should be explored further as an option for the potential treatment of degenerative disc disease.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 35 条
[1]   Porcine Intervertebral Disc Repair Using Allogeneic Juvenile Articular Chondrocytes or Mesenchymal Stem Cells [J].
Acosta, Frank L., Jr. ;
Metz, Lionel ;
Adkisson, Huston Davis ;
Liu, Jane ;
Carruthers-Liebenberg, Ellen ;
Milliman, Curt ;
Maloney, Michael ;
Lotz, Jeffrey C. .
TISSUE ENGINEERING PART A, 2011, 17 (23-24) :3045-3055
[2]   Adjacent segment degeneration after instrumented posterolateral lumbar fusion: a prospective cohort study with a minimum five-year follow-up [J].
Anandjiwala, Jigar ;
Seo, Jun-Yeong ;
Ha, Kee-Yong ;
Oh, In-Soo ;
Shin, Dong-Cheul .
EUROPEAN SPINE JOURNAL, 2011, 20 (11) :1951-1960
[3]   Lumbar disc degeneration:: Epidemiology and genetics [J].
Battié, MC ;
Videman, T .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A :3-9
[4]   A feasibility study of in vivo T1ρ imaging of the inteirvertebral disc [J].
Blumenkrantz, Gabrielle ;
Li, Xiaojuan ;
Han, Eric T. ;
Newitt, David C. ;
Crane, Jason C. ;
Link, Thomas M. ;
Majumdar, Sharmila .
MAGNETIC RESONANCE IMAGING, 2006, 24 (08) :1001-1007
[5]  
Bowles RD, 2010, TISSUE ENG PT A, V16, P1339, DOI [10.1089/ten.tea.2009.0442, 10.1089/ten.TEA.2009.0442]
[6]   Tissue-engineered intervertebral discs produce new matrix, maintain disc height, and restore biomechanical function to the rodent spine [J].
Bowles, Robby D. ;
Gebhard, Harry H. ;
Haertl, Roger ;
Bonassar, Lawrence J. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2011, 108 (32) :13106-13111
[7]   Image-based tissue engineering of a total intervertebral disc implant for restoration of function to the rat lumbar spine [J].
Bowles, Robby D. ;
Gebhard, Harry H. ;
Dyke, Jonathan P. ;
Ballon, Douglas J. ;
Tomasino, Andre ;
Cunningham, Matthew E. ;
Haertl, Roger ;
Bonassar, Lawrence J. .
NMR IN BIOMEDICINE, 2012, 25 (03) :443-451
[8]   Porous silk scaffolds can be used for tissue engineering annulus fibrosus [J].
Chang, G. ;
Kim, H. -J. ;
Kaplan, D. ;
Vunjak-Novakovic, G. ;
Kandel, R. A. .
EUROPEAN SPINE JOURNAL, 2007, 16 (11) :1848-1857
[9]   Motion Preservation and Clinical Outcome of Porous Coated Motion Cervical Disk Arthroplasty [J].
Choi, David ;
Petrik, Vladimir ;
Fox, Sally ;
Parkinson, Joy ;
Timothy, Jake ;
Gullan, Richard .
NEUROSURGERY, 2012, 71 (01) :30-36
[10]  
Gebhard Harry, 2011, Evid Based Spine Care J, V2, P29, DOI 10.1055/s-0030-1267084