Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures

被引:62
|
作者
Weil, Yoram A. [1 ]
Qawasmi, Feras [1 ]
Liebergall, Meir [1 ]
Mosheiff, Rami [1 ]
Khoury, Amal [1 ]
机构
[1] Hadassah Hebrew Univ Hosp, Dept Orthoped, Orthopaed Trauma Serv, POB 12000, IL-91120 Jerusalem, Israel
关键词
Hip fractures; Femoral fractures; Fully threaded screws; FIBULAR STRUT GRAFT; INTERNAL-FIXATION; INTRACAPSULAR FRACTURES; OUTCOMES; ADULT; FEMUR;
D O I
10.1007/s00402-018-2896-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Femoral neck fractures (FNF) are becoming increasingly common as population ages. Nondisplaced fractures are commonly treated by cancellous, parallel placed, partially threaded cannulated screws (PTS). This allows controlled fracture impaction. However, sliding implants can lead to femoral neck shortening (FNS) that has been shown to be correlated with reduced quality of life and impaired gait pattern. Recently, in our institution we have changed the fixation of FNF to fully threaded screws (FTS) with or without an additional partially threaded screw in order to minimize this phenomenon. The aim of this study was to compare the FNS in patients treated with FTS as compared with our historical controls treated with PTS. Patients and methods Between 2014 and 2016, 38 patients with FNF were treated with FTS. Out of the 38, 24 were available for radiographic follow-up. 41 patients treated previously with PTS were available as a control group. Radiographic analysis was performed to assess the FNF in three vectors: Horizontal (X), Vertical (Y) and overall (Z) according to the neck-shaft angle. Results Time for admission to surgery was longer in the PTS group (p = 0.04). Patient demographics and major complication rates were similar in the two patient groups. Average FNS in the X axis was significantly smaller in the FTS group than in the PTS group (2.8 +/- 3.6 vs 7.6 +/- 4.2 mm, p < 0.01) as well as the Y axis (1.2 +/- 2.6 vs 4.9 +/- 4.2 mm, p < 0.01) and thus also decreased overall Z shortening (2.3 +/- 3.5 vs 6.23 +/- 4.5 mm, p < 0.01). There was a tendency towards a more valgus reduction in the PTS (137A degrees vs 134A degrees, p = 0.08). There was a significantly smaller number of FTS patients with moderate (5-10 mm) or severe (> 10 mm) FNS. Screw pull-out > 5 mm occurred in 17/41 patients in the PTS but none in the FTS group (p < 0.01). Conclusion This study proves that use of FTS improves the radiographic results following FNF fixation using cannulated screws.
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [1] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667
  • [2] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [3] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Kai-xuan Yuan
    Fan Yang
    Kai Fu
    Dao-yu Zhu
    Chen-yi Jiang
    Dong-xu Jin
    Ze-hao Wang
    Xiao-yuan Peng
    You-Shui Gao
    Peng-bo Luo
    Journal of Orthopaedic Surgery and Research, 17
  • [4] Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults
    Zheng, Shunze
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Chen, Bin
    Zheng, Ke
    Lin, Fengfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [5] Cannulated screws fixation as an alternative treatment of femoral neck osteoporotic fractures
    Ciesielczyk, B
    Tuchocka-Piotrowska, A
    ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 : 516 - +
  • [6] Fully-threaded cannulated screws versus partially-threaded cannulated screws for femoral neck fractures: a systematic review and meta-analysis
    Mingwang Jia
    Chenning Ding
    Xin Zhao
    Xing Han
    Jiahui Zhang
    Xiguang Sang
    Journal of Orthopaedic Surgery and Research, 19 (1)
  • [7] The Effect of Configuration of Rhombic Cannulated Screws on Internal Fixation of Femoral Neck Fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Yingchao
    Zhang, Ruipeng
    Hou, Zhiyong
    Zhang, Yingze
    ORTHOPEDICS, 2020, 43 (02) : E72 - E78
  • [8] Fixation of femoral neck fractures using divergent versus parallel cannulated screws
    Papanastassiou I.D.
    Mavrogenis A.F.
    Kokkalis Z.T.
    Nikolopoulos K.
    Skourtas K.
    Papagelopoulos P.J.
    Journal of Long-Term Effects of Medical Implants, 2011, 21 (01) : 63 - 69
  • [9] High incidence of “in–out–in” posterosuperior screws after cannulated screw fixation of femoral neck fractures
    Brandon J. Yuan
    Mohamad Tayseer Shamaa
    William R. Aibinder
    Joshua A. Parry
    William W. Cross
    Jonathan D. Barlow
    Stephen A. Sems
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 1417 - 1420
  • [10] Femoral Neck Shortening and Varus Collapse After Navigated Fixation of Intracapsular Femoral Neck Fractures
    Weil, Yoram A.
    Khoury, Amal
    Zuaiter, Imad
    Safran, Ori
    Liebergall, Meir
    Mosheiff, Rami
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (01) : 19 - 23