Randomized prospective evaluation of the wound integrity of primary clear corneal incisions made with a femtosecond laser versus a manual keratome

被引:12
作者
Donnenfeld, Eric [1 ]
Rosenberg, Eric [2 ]
Boozan, Henry [1 ]
Davis, Zac [1 ]
Nattis, Alanna [1 ]
机构
[1] Ophthalm Consultants Long Isl, 711 Stewart Ave,Suite 160, Garden City, NY 11530 USA
[2] New York Med Coll, Dept Ophthalmol, Valhalla, NY 10595 USA
关键词
CATARACT-SURGERY; STROMAL HYDRATION; COHERENCE TOMOGRAPHY; ANTERIOR-CHAMBER; OCULAR BANDAGE; ENDOPHTHALMITIS; OUTCOMES; INGRESS;
D O I
10.1016/j.jcrs.2017.12.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the wound integrity of femtosecond laser assisted 110-degree reverse side-cut clear corneal incisions (CCIs) with femtosecond laser-assisted 70-degree forward side-cut and manual CCIs in patients having cataract surgery. Setting: Island Eye Surgicenter, Cane Place, New York, USA. Design: Prospective case series. Methods: Patients having cataract surgery were randomized into 3 treatment groups as follows: Group A had 110-degree femtosecond reverse side-cut CCIs, Group B had 70-degree femtosecond forward side-cut CCIs, Group C had manual CCIs. At the conclusion of surgery, the integrity of the CCI was measured by raising intraocular pressure (IOP) until the CCI began to leak. Postoperatively, the CCIs were assessed for wound leakage at 1 day, 2 weeks, and 1 month. Results: The study comprised 45 patients (45 eyes, 15 in each treatment group). The mean lOP at which CCIs leaked (in response to anterior chamber balanced salt solution irrigation) was statistically significantly higher in Group A (28.20 mm Hg +/- 11.69 [SD]) than in Group B (15.07 +/- 10.64 mm Hg; P = .005) and Group C (9.93 +/- 9.90 mm Hg; P < .001). At 1 day postoperatively, the Seidel test with pressure showed no leakage in any of the Group A eyes; however, 53% of eyes in Group B and 87% in Group C showed wound leakage. Conclusion: The femtosecond laser-created reverse side-cut CCIs required significantly higher IOP intraoperatively before leaking and resulted in better wound integrity with significantly less wound leakage postoperatively than laser-created forward side-cut or manual CCIs. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:329 / 335
页数:7
相关论文
共 30 条
[1]   Femtosecond-laser assisted cataract surgery: a review [J].
Abouzeid, Hana ;
Ferrini, Walter .
ACTA OPHTHALMOLOGICA, 2014, 92 (07) :597-603
[2]   Adherent ocular bandage for clear corneal incisions used in cataract surgery [J].
Calladine, Daniel ;
Ward, Mina ;
Packard, Richard .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (11) :1839-1848
[3]   Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture [J].
Calladine, Daniel ;
Tanner, Vaughan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (08) :1367-1371
[4]  
Cao H, 2013, PLOS ONE, V8, DOI [10.1371/journal.pone.0052853, 10.1371/journal.pone.0071731]
[5]   Case-control study of endophthalmitis after cataract surgery comparing scleral tunnel and clear corneal wounds [J].
Cooper, BA ;
Holekamp, NM ;
Bohigian, G ;
Thompson, PA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (02) :300-305
[6]   Microincisions in cataract surgery [J].
Dewey, Steven ;
Beiko, George ;
Braga-Mele, Rosa ;
Nixon, Donald R. ;
Raviv, Tal ;
Rosenthal, Kenneth .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (09) :1549-1557
[7]   Profile of clear corneal cataract incisions demonstrated by ocular coherence tomography [J].
Fine, I. Howard ;
Hoffman, Richard S. ;
Packer, Mark .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (01) :94-97
[8]   Wound Architecture of Clear Corneal Incision With or Without Stromal Hydration Observed With 3-Dimensional Optical Coherence Tomography [J].
Fukuda, Shinichi ;
Kawana, Keisuke ;
Yasuno, Yoshiaki ;
Oshika, Tetsuro .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (03) :413-419
[9]   Comparison of morphologic features of clear corneal incisions created with a femtosecond laser or a keratome [J].
Grewal, Dilraj S. ;
Basti, Surendra .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04) :521-530
[10]   Leak-Free Clear Corneal Incisions in Human Cadaver Tissue: Femtosecond Laser-Created Multiplanar Incisions [J].
Hill, James E. ;
Binder, Perry S. ;
Huang, Ling C. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (04) :257-261