Intermediate-Term Results of 142 Single-Design, Rotating-Hinge Implants: Frequent Complications May Not Preclude Salvage of Severely Affected Knees

被引:43
作者
Farid, Yasser R. [1 ,2 ]
Thakral, Rishi [2 ,3 ]
Finn, Henry A. [2 ,4 ]
机构
[1] Univ Illinois, Clin Orthoped Surg, Chicago, IL 60640 USA
[2] Weiss Mem Hosp, Bone & Joint Replacement Ctr, Chicago, IL 60640 USA
[3] Univ Chicago, Chicago, IL 60637 USA
[4] Univ Chicago, Surg, Chicago, IL 60637 USA
基金
美国国家卫生研究院;
关键词
rotating-hinge; knee arthroplasty; revision; salvage; complications; FOLLOW-UP; ARTHROPLASTY; REPLACEMENT; PROSTHESIS; TUMORS; FEMUR;
D O I
10.1016/j.arth.2015.06.033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rotating-hinge knee prostheses have low survivorship and high complications except in primary arthroplasties in elderly patients. We retrospectively reviewed 142 single third-generation design, rotating hinge prostheses (11 primary procedures and 131 revisions) at 57 months follow up. Implant survival was 73 %. Successful two-stage reimplantation for prosthetic infection was 78.4% but new infection rate was 22%. The tibial component was durable while the femoral component was problematic. We observed only one patellar maltracking and no polyethylene wear. A third generation rotating-hinge arthroplasty reconstruction was reliable in complex problems. Outcomes in primary situations were excellent. Complications were the rule rather than the exception in revisions. With timely intervention, attention to soft tissue coverage, and realistic expectations, complications were contained and functional benefits were appreciable. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:2173 / 2180
页数:8
相关论文
共 29 条
[1]  
Barrack RL, 2001, CLIN ORTHOP RELAT R, P292
[2]   Distal Femoral Replacement in Nontumor Cases with Severe Bone Loss and Instability [J].
Berend, Keith R. ;
Lombardi, Adolph V., Jr. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (02) :485-492
[3]   MODULAR UNCEMENTED PROSTHETIC RECONSTRUCTION AFTER RESECTION OF TUMORS OF THE DISTAL FEMUR [J].
CAPANNA, R ;
MORRIS, HG ;
CAMPANACCI, D ;
DELBEN, M ;
CAMPANACCI, M .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02) :178-186
[4]   Problems with the Rotaflex - A 10-year review of a rotating hinge prosthesis [J].
David, HG ;
Bishay, M ;
James, ETR .
JOURNAL OF ARTHROPLASTY, 1998, 13 (04) :402-408
[5]   The role of the rotating hinge prosthesis in the salvage arthroplasty setting [J].
Deehan, David John ;
Murray, James ;
Birdsall, Paul D. ;
Holland, James P. ;
Pinder, Ian M. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (05) :683-688
[6]  
Finn HA, 1991, J BONE JOINT SU B S1, V74B, P177
[7]  
Finn HA, 1991, COMPLICATIONS LIMB S, P413
[8]  
FREEMAN PA, 1973, CLIN ORTHOP RELAT R, P85
[9]   Complications following rotating hinge Endo-Modell (Link®) knee arthroplasty [J].
Guenoun, B. ;
Latargez, L. ;
Freslon, M. ;
Defossez, G. ;
Salas, N. ;
Gayet, L. -E. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (07) :529-536
[10]   Hinged Total Knee Arthroplasty in the Presence of Ligamentous Deficiency [J].
Hernandez-Vaquero, Daniel ;
Sandoval-Garcia, Manuel A. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (05) :1248-1253