Poly 3,4-ethylenedioxythiophene as an entrapment support for amperometric enzyme sensor

被引:59
作者
Fabiano, S
Tran-Minh, C
Piro, B
Dang, LA
Pham, MC
Vittori, O
机构
[1] Ecole Des Mines St Etienne, Ctr SPIN Lab Genie Enzymat, F-42023 St Etienne 2, France
[2] Univ Paris 07, CNRS, UMR 7086, ITODYS, F-75005 Paris, France
[3] UCBL, F-69622 Villeurbanne, France
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2002年 / 21卷 / 1-2期
关键词
electropolymerization; conducting polymer; glucose enzyme electrodes; FIA;
D O I
10.1016/S0928-4931(02)00060-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A conducting polymer of poly 3,4-ethylenedioxythiophene (PEDT) was used as a matrix for entrapment of enzymes onto a platinum electrode surface in order to construct amperometric biosensors. Glucose oxidase (GOD) was used as an example, and it was entrapped in the polymer during the electrochemical polymerization. Glucose in oxygenated solutions was tested by amperometric measurements at +650 mV (vs. SCE) in a batch system. The influence of several experimental parameters in the electropolymerization process was explored to optimize the analytical performance. The detection limit and sensitivity for this biosensor were 4 x 10(-5) M and 15.2 mA M-1 cm(-2), respectively. A linear range of response was found from 0.2 to 8 mM of glucose. The response time was 2-5 s. The stability of the electropolymerized films was evaluated in operational conditions. The glucose probe, stored in buffer at 4 degreesC when not in use, showed a residual activity of 40% after about 1 month. Glucose in synthetic serum was determined under flow injection conditions using an amperometric flow cell. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 33 条
[1]  
BARMAN TE, 1969, ENZYME HDB, V1, P112
[2]   THE APPLICATION OF CONDUCTING POLYMERS IN BIOSENSORS [J].
BARTLETT, PN ;
BIRKIN, PR .
SYNTHETIC METALS, 1993, 61 (1-2) :15-21
[3]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[4]   DEVELOPMENT OF AMPEROMETRIC BIOSENSORS BASED ON THE IMMOBILIZATION OF ENZYMES IN POLYMER-FILMS ELECTROGENERATED FROM A SERIES OF AMPHIPHILIC PYRROLE DERIVATIVES [J].
COCHEGUERENTE, L ;
COSNIER, S ;
INNOCENT, C ;
MAILLEY, P .
ANALYTICA CHIMICA ACTA, 1995, 311 (01) :23-30
[5]   Poly(pyrrole-biotin): a new polymer for biomolecule grafting on electrode surfaces [J].
Cosnier, S ;
Lepellec, A .
ELECTROCHIMICA ACTA, 1999, 44 (11) :1833-1836
[6]   Electropolymerization of amphiphilic monomers for designing amperometric biosensors [J].
Cosnier, S .
ELECTROANALYSIS, 1997, 9 (12) :894-902
[7]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923
[8]   CHARACTERIZATION OF THE BIOCHEMICAL BEHAVIOR OF GLUCOSE-OXIDASE ENTRAPPED IN A POLYPYRROLE FILM [J].
FORTIER, G ;
BELANGER, D .
BIOTECHNOLOGY AND BIOENGINEERING, 1991, 37 (09) :854-858
[9]   OPTIMIZATION OF A POLYPYRROLE GLUCOSE-OXIDASE BIOSENSOR [J].
FORTIER, G ;
BRASSARD, E ;
BELANGER, D .
BIOSENSORS & BIOELECTRONICS, 1990, 5 (06) :473-490
[10]   IMMOBILIZATION OF GLUCOSE-OXIDASE IN FERROCENE-MODIFIED PYRROLE POLYMERS [J].
FOULDS, NC ;
LOWE, CR .
ANALYTICAL CHEMISTRY, 1988, 60 (22) :2473-2478