Effects of posture and bronchoconstriction on low-frequency input and transfer impedances in humans

被引:11
作者
Dellacà, RL
Black, LD
Atileh, H
Pedotti, A
Lutchen, KR
机构
[1] Politecn Milan, Dipartimento Bioingn, TBMLab, I-20133 Milan, Italy
[2] Boston Univ, Dept Biomed Engn, Boston, MA 02215 USA
关键词
lung impedance; chest wall impedance; rib cage; abdomen; forced oscillation technique;
D O I
10.1152/japplphysiol.00721.2003
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We simultaneously evaluated the mechanical response of the total respiratory system, lung, and chest wall to changes in posture and to bronchoconstriction. We synthesized the optimal ventilation waveform (OVW) approach, which simultaneously provides ventilation and multifrequency forcing, with optoelectronic plethysmography (OEP) to measure chest wall flow globally and locally. We applied an OVW containing six frequencies from 0.156 to 4.6 Hz to the mouth of six healthy men in the seated and supine positions, before and after methacholine challenge. We measured mouth, esophageal, and transpulmonary pressures, airway flow by pneumotachometry, and total chest wall, pulmonary rib cage, and abdominal volumes by OEP. We computed total respiratory, lung, and chest wall input impedances and the total and regional transfer impedances (Ztr). These data were appropriately sensitive to changes in posture, showing added resistance in supine vs. seated position. The Ztr were also highly sensitive to lung constriction, more so than input impedance, as the former is minimally distorted by shunting of flow into alveolar gas compression and airway walls. Local impedances show that, during bronchoconstriction and at typical breathing frequencies, the contribution of the abdomen becomes amplified relative to the rib cage. A similar redistribution occurs when passing from seated to supine. These data suggest that the OEP-OVW approach for measuring Ztr could noninvasively track important lung and respiratory conditions, even in subjects who cannot cooperate. Applications might range from routine evaluation of airway hyperreactivity in asthmatic subjects to critical conditions in the supine position during mechanical ventilation.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 43 条
[1]  
Agostoni A, 1986, HDB PHYSL 3, P113
[2]   Optoelectronic plethysmography in intensive care patients [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Pedotti, A ;
Gattinoni, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (05) :1546-1552
[3]   Human respiratory muscle actions and control during exercise [J].
Aliverti, A ;
Cala, SJ ;
Duranti, R ;
Ferrigno, G ;
Kenyon, CM ;
Pedotti, A ;
Scano, G ;
Sliwinski, P ;
Macklem, PT ;
Yan, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (04) :1256-1269
[4]   Compartmental analysis of breathing in the supine and prone positions by optoelectronic plethysmography [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Gattinoni, L ;
Pedotti, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (01) :60-70
[5]   Transfer impedance of the respiratory system by forced oscillation technique and optoelectronic Plethysmography [J].
Aliverti, A ;
Dellacà, RL ;
Pedotti, A .
ANNALS OF BIOMEDICAL ENGINEERING, 2001, 29 (01) :71-82
[6]   LUNG, CHEST-WALL, AND TOTAL RESPIRATORY SYSTEM RESISTANCES AND ELASTANCES IN THE NORMAL RANGE OF BREATHING [J].
BARNAS, GM ;
CAMPBELL, DN ;
MACKENZIE, CF ;
MENDHAM, JE ;
FAHY, BG ;
RUNCIE, CJ ;
MENDHAM, GE .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (01) :110-113
[7]   IMPEDANCE AND RELATIVE DISPLACEMENTS OF RELAXED CHEST-WALL UP TO 4 HZ [J].
BARNAS, GM ;
YOSHINO, K ;
LORING, SH ;
MEAD, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (01) :71-81
[8]   EFFECT OF POSTURE ON LUNG AND REGIONAL CHEST-WALL MECHANICS [J].
BARNAS, GM ;
GREEN, MD ;
MACKENZIE, CF ;
FLETCHER, SJ ;
CAMPBELL, DN ;
RUNCIE, C ;
BRODERICK, GE .
ANESTHESIOLOGY, 1993, 78 (02) :251-259
[9]  
BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
[10]   VALIDATION OF ESOPHAGEAL BALLOON TECHNIQUE AT DIFFERENT LUNG-VOLUMES AND POSTURES [J].
BAYDUR, A ;
CHA, EJ ;
SASSOON, CSH .
JOURNAL OF APPLIED PHYSIOLOGY, 1987, 62 (01) :315-321