Emerging flow injection mass spectrometry methods for high-throughput quantitative analysis

被引:77
|
作者
Nanita, Sergio C. [1 ]
Kaldon, Laura G. [1 ]
机构
[1] Stine Haskell Res Ctr, DuPont Crop Protect, Newark, DE 19714 USA
关键词
Tandemmass spectrometry; Flow injection analysis; High-throughput analysis; Trace-level analysis; Complex matrices; Bio-analysis; Pesticides; Pharmaceuticals; SOLID-PHASE EXTRACTION; DIETARY-SUPPLEMENT MATERIALS; LIQUID-CHROMATOGRAPHY; ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE; RAPID-DETERMINATION; HUMAN PLASMA; PESTICIDES; QUANTIFICATION; DRUGS;
D O I
10.1007/s00216-015-9193-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Where does flow injection analysis mass spectrometry (FIA-MS) stand relative to ambient mass spectrometry (MS) and chromatography-MS? Improvements in FIA-MS methods have resulted in fast-expanding uses of this technique. Key advantages of FIA-MS over chromatography-MS are fast analysis (typical run time <60 s) and method simplicity, and FIA-MS offers high-throughput without compromising sensitivity, precision and accuracy as much as ambient MS techniques. Consequently, FIA-MS is increasingly becoming recognized as a suitable technique for applications where quantitative screening of chemicals needs to be performed rapidly and reliably. The FIA-MS methods discussed herein have demonstrated quantitation of diverse analytes, including pharmaceuticals, pesticides, environmental contaminants, and endogenous compounds, at levels ranging from parts-per-billion (ppb) to parts-per-million (ppm) in very complex matrices (such as blood, urine, and a variety of foods of plant and animal origin), allowing successful applications of the technique in clinical diagnostics, metabolomics, environmental sciences, toxicology, and detection of adulterated/counterfeited goods. The recent boom in applications of FIA-MS for high-throughput quantitative analysis has been driven in part by (1) the continuous improvements in sensitivity and selectivity of MS instrumentation, (2) the introduction of novel sample preparation procedures compatible with standalone mass spectrometric analysis such as salting out assisted liquid-liquid extraction (SALLE) with volatile solutes and NH4+ QuEChERS, and (3) the need to improve efficiency of laboratories to satisfy increasing analytical demand while lowering operational cost. The advantages and drawbacks of quantitative analysis by FIA-MS are discussed in comparison to chromatography-MS and ambient MS (e.g., DESI, LAESI, DART). Generally, FIA-MS sits 'in the middle' between ambient MS and chromatography-MS, offering a balance between analytical capability and sample analysis throughput suitable for broad applications in life sciences, agricultural chemistry, consumer safety, and beyond.
引用
收藏
页码:23 / 33
页数:11
相关论文
共 50 条
  • [1] Emerging flow injection mass spectrometry methods for high-throughput quantitative analysis
    Sergio C. Nanita
    Laura G. Kaldon
    Analytical and Bioanalytical Chemistry, 2016, 408 : 23 - 33
  • [2] High-Throughput Pesticide Residue Quantitative Analysis Achieved by Tandem Mass Spectrometry with Automated Flow Injection
    Nanita, Sergio C.
    Pentz, Anne M.
    Bramble, Frederick Q.
    ANALYTICAL CHEMISTRY, 2009, 81 (08) : 3134 - 3142
  • [3] A tool for quantitative analysis of high-throughput mass spectrometry data
    Park, S. Kyu
    Venable, J. D.
    Xu, T.
    Liao, L.
    Yates, J. R., III
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S199 - S199
  • [4] The automatic visualisation of carry-over in high-throughput flow injection analysis mass spectrometry
    Richmond, R
    Görlach, E
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 175 - 183
  • [5] High-throughput chemical residue analysis by fast extraction and dilution flow injection mass spectrometry
    Nanita, Sergio C.
    ANALYST, 2011, 136 (02) : 285 - 287
  • [6] High-Throughput Quantitative Analysis by Desorption Electrospray Ionization Mass Spectrometry
    Manicke, Nicholas E.
    Kistler, Thomas
    Ifa, Demian R.
    Cooks, R. Graham
    Ouyang, Zheng
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (02) : 321 - 325
  • [7] Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry
    Hopfgartner, G. (gerard.hopfgartner@pharm.unige.ch), 1600, John Wiley and Sons Inc. (22):
  • [8] Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry
    Hopfgartner, G
    Bourgogne, E
    MASS SPECTROMETRY REVIEWS, 2003, 22 (03) : 195 - 214
  • [9] High-throughput quantification of stabilizers in polymeric materials by flow injection tandem mass spectrometry
    Beissmann, Susanne
    Reisinger, Michael
    Reimann, Andreas
    Klampfl, Christian W.
    Buchberger, Wolfgang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (08) : 939 - 947
  • [10] High-throughput, nontargeted metabolite fingerprinting using nominal mass flow injection electrospray mass spectrometry
    Manfred Beckmann
    David Parker
    David P Enot
    Emilie Duval
    John Draper
    Nature Protocols, 2008, 3 : 486 - 504