Optimal structure of magnetic and conductive layers of a magnetically shielded room

被引:10
|
作者
Yamazaki, Keita [1 ]
Muramatsu, Kazuhiro
Hirayama, Masayuki
Haga, Akira
Torita, Fumihiko
机构
[1] Takenaka Corp, Inst Res & Dev, Chiba 2701395, Japan
[2] Saga Univ, Dept Elect & Elect Engn, Saga 8408502, Japan
[3] Tohoku Gakuin Univ, Dept Elect Engn & Informat Technol, Sendai, Miyagi 9808537, Japan
关键词
magnetic field analysis; magnetically shielded room; multilayers; shielding effect; DESIGN;
D O I
10.1109/TMAG.2006.879156
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Although the method of optimal design of magnetically shielded rooms (MSRs) for dc magnetic noise seems to be well established, that for ac magnetic noise at a frequency range from 0.01 to 1 Hz is also required for measurements of extremely weak magnetic fields such as biomagnetic measurements. However, such a method cannot easily be established due to eddy current effects. In order to establish an optimal design method of an MSR for low frequency ac magnetic noise, we have investigated an optimal structure of the magnetic and conductive layers using three-dimensional (3-D) linear magnetic field analysis taking into account eddy currents. We show why a structure which sandwiches the conductive layer between double magnetic layers gives high shielding effect. Moreover, we found that the spacing between the layers does not affect the shielding effect for ac magnetic noise. This is useful knowledge from the standpoint of MSR production.
引用
收藏
页码:3524 / 3526
页数:3
相关论文
共 50 条
  • [21] A magnetically shielded room with ultra low residual field and gradient
    Altarev, I.
    Babcock, E.
    Beck, D.
    Burghoff, M.
    Chesnevskaya, S.
    Chupp, T.
    Degenkolb, S.
    Fan, I.
    Fierlinger, P.
    Frei, A.
    Gutsmiedl, E.
    Knappe-Grueneberg, S.
    Kuchler, F.
    Lauer, T.
    Link, P.
    Lins, T.
    Marino, M.
    McAndrew, J.
    Niessen, B.
    Paul, S.
    Petzoldt, G.
    Schlaepfer, U.
    Schnabel, A.
    Sharma, S.
    Singh, J.
    Stoepler, R.
    Stuiber, S.
    Sturm, M.
    Taubenheim, B.
    Trahms, L.
    Voigt, J.
    Zechlau, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (07):
  • [22] Study of open-type magnetically shielded room for MRI
    Kamata K.
    Tamari Y.
    Temma S.
    Goto K.
    Yunokuchi K.
    Kamata, Kiyotaka (kamata@kagoshima-ct.ac.jp), 2018, Institute of Electrical Engineers of Japan (138) : 799 - 804
  • [23] Passive Shimming of Magnetically Shielded Room Using Ferromagnetic Plates
    Jin, Shixu
    Kuwahata, Akihiro
    Chikaki, Shinichi
    Hatano, Mutsuko
    Sekino, Masaki
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (02)
  • [24] Modeling of Leakage Magnetic Field of Electric Machines Using Blocks with Magnetizations for Design of Magnetically Shielded Room
    Muramatsu, Kazuhiro
    Gao, Yanhui
    Moriyama, Yusuke
    Dozono, Hiroshi
    Nishino, Takaaki
    Miura, Kazuyuki
    2016 IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (CEFC), 2016,
  • [25] Modeling of Leakage Magnetic Field of Electric Machines Using Blocks With Magnetizations for Design of Magnetically Shielded Room
    Muramatsu, Kazuhiro
    Gao, Yanhui
    Moriyama, Yusuke
    Dozono, Hiroshi
    Nishino, Takaaki
    Miura, Kazuyuki
    IEEE TRANSACTIONS ON MAGNETICS, 2017, 53 (06)
  • [26] Hybrid MEG-MRI: Geometry and Time Course of Magnetic Fields Inside a Magnetically Shielded Room
    Vesanen, P. T.
    Nieminen, J. O.
    Dabek, J.
    Ilmoniemi, R. J.
    17TH INTERNATIONAL CONFERENCE ON BIOMAGNETISM ADVANCES IN BIOMAGNETISM - BIOMAG2010, 2010, 28 : 78 - 81
  • [27] Dynamic stabilisation of magnetic fields measured inside a magnetically shielded room using an external coil system
    Zhao, Jiye
    Tian, Pengtao
    Sun, Jinji
    Zhang, Haifeng
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2024, 57 (23)
  • [28] Design and Test of a Magnetic-Field Compensation Coil Without Interference With the Door of a Magnetically Shielded Room
    Liu, Xikai
    Wu, Chen
    Zhang, Lu
    Wen, Tong
    Zheng, Shiqiang
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [29] A MAGNETIC SHIELDED ROOM DESIGNED FOR MAGNETOENCEPHALOGRAPHY
    SULLIVAN, GW
    LEWIS, PS
    GEORGE, JS
    FLYNN, ER
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (04): : 765 - 770
  • [30] Effective Suppression of Residual Magnetic Interference in a Conductive Shielded Room for Ultra-Low Field Nuclear Magnetic Resonance
    Tan, Yiqiu
    Zhou, Danfeng
    Song, Mengxiao
    Li, Jie
    APPLIED SCIENCES-BASEL, 2020, 10 (11):