Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement

被引:120
作者
Turkyilmaz, I.
Toezuem, T. F.
Tumer, C.
Ozbek, E. N.
机构
[1] Hacettepe Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Periodontol, Ankara, Turkey
[3] Hacettepe Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Ankara, Turkey
[4] Baskent Univ, Fac Dent, Dept Periodontol, TR-06490 Ankara, Turkey
关键词
dental implants; bone density; computerized tomography; fastening torque; resonance frequency analysis;
D O I
10.1111/j.1365-2842.2006.01692.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to determine the bone density in the designated implant sites using computerized tomography (CT), the fastening torque values of dental implants, and the implant stability values using resonance frequency analysis. Further aim was to evaluate a possible correlation between bone density, fastening torque and implant stability. Eighty-five patients were treated with 158 Branemark System implants. CT machine was used for preoperative evaluation of the jawbone for each patient, and bone densities were recorded in Hounsfield units (HU). The fastening torque values of all implants were recorded with the OsseoCare equipment. Implant stability measurements were performed with the Osstell machine. The average bone density and fastening torque values were 751.4 +/- 256 HU and 39.7 +/- 7 Ncm for 158 implants. The average primary implant stability was 73.2 +/- 6 ISQ for seventy implants. Strong correlations were observed between the bone density, fastening torque and implant stability values of Branemark System TiUnite MKIII implants at implant placement (P < 0.001). These results strengthen the hypothesis that it may be possible to predict and quantify initial implant stability and bone quality from pre-surgical CT diagnosis.
引用
收藏
页码:881 / 888
页数:8
相关论文
共 39 条
[1]  
Aranyarachkul P, 2005, INT J ORAL MAX IMPL, V20, P416
[2]   Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible [J].
Beer, A ;
Gahleitner, A ;
Holm, A ;
Tschabitscher, M ;
Homolka, P .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) :616-620
[3]  
Branemark P.I., 1985, TISSUE INTEGRATED PR, Vfirst, P11
[4]   A 5-year prospective study on small diameter screw-shaped oral implants [J].
Comfort, MB ;
Chu, FCS ;
Chai, J ;
Wat, PYP ;
Chow, TW .
JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) :341-345
[5]  
da Cunha HA, 2004, INT J ORAL MAX IMPL, V19, P578
[6]   A retrospective analysis of factors associated with multiple implant failures in maxillae [J].
Ekfeldt, A ;
Christiansson, U ;
Eriksson, T ;
Lindén, U ;
Lundqvist, S ;
Rundcrantz, T ;
Johansson, LÅ ;
Nilner, K ;
Billström, C .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (05) :462-467
[7]  
Engquist B, 1988, Int J Oral Maxillofac Implants, V3, P129
[8]   Resonance frequency analysis of one-stage dental implant stability during the osseointegration period [J].
Ersanli, S ;
Karabuda, C ;
Beck, F ;
Leblebicioglu, B .
JOURNAL OF PERIODONTOLOGY, 2005, 76 (07) :1066-1071
[9]   Three-dimensional morphometric analysis of human cadaver bone: microstructural data from maxilla and mandible [J].
Fanuscu, MI ;
Chang, TL .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :213-218
[10]  
Friberg B, 1999, INT J ORAL MAX SURG, V28, P297