Multimodal Imaging Using Optical Coherence Tomography and Endolaryngeal Ultrasonography in a New Rabbit VX2 Laryngeal Cancer Model

被引:7
作者
Oak, Chulho [1 ,2 ]
Ahn, Yeh-Chan [1 ,3 ,4 ]
Nam, Sung-Jin [1 ,2 ]
Jung, Maan Hong [1 ,2 ]
Hwang, Sang Seok [1 ,3 ,4 ]
Chae, Yu-Gyeong [1 ,3 ,4 ]
Lee, Hyoung Shin [1 ,5 ]
Lee, Kang Dae [1 ,5 ]
Jung, Min Jung [1 ,6 ]
Chun, Bong Kwon [1 ,6 ]
Lee, Hae Young [1 ,7 ]
Park, Eun-Kee [1 ,8 ]
Kim, Sung Won [1 ,5 ]
机构
[1] Innovat Biomed Technol Res Ctr, Busan 602030, South Korea
[2] Kosin Univ, Coll Med, Dept Internal Med, Busan 602030, South Korea
[3] Pukyong Natl Univ, Dept Biomed Engn, Busan 608737, South Korea
[4] Pukyong Natl Univ, Ctr Marine Integrated Biomed Technol, Busan 608737, South Korea
[5] Kosin Univ, Dept Otolaryngol Head & Neck Surg, Coll Med, Busan 602030, South Korea
[6] Kosin Univ, Dept Pathol, Coll Med, Busan 602030, South Korea
[7] Kosin Univ, Dept Thorac & Cardiovasc Surg, Coll Med, Busan 602030, South Korea
[8] Kosin Univ, Dept Med Humanities & Social Med, Coll Med, Busan 602030, South Korea
基金
新加坡国家研究基金会;
关键词
optical coherence tomography; endolaryngeal ultrasonography; vocal fold; laryngeal cancer; CLINICAL-VALUE; TUMOR; ULTRASOUND; MARGINS;
D O I
10.1002/lsm.22409
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: Optical coherence tomography (OCT) provides ultrahigh-resolution imaging of tissues within a depth of a few millimeters, whereas ultrasonography provides good imaging further below the surface. We aimed to develop a minimally invasive rabbit model of VX2 laryngeal cancer, suitable for these two imaging modalities through a transoral approach. We also sought to study the utility of combined OCT and endolaryngeal ultrasonography (EUS) for evaluation of early and advanced laryngeal cancer, using this model. Materials and Methods: VX2 tumor suspension was inoculated into the vocal folds of ten rabbits by injection through the trans-thyrohyoid membrane. The tumor model was characterized by rigid laryngoscopy and the tumor generation rate was 80% (8/10). Correlation between frequency-domain OCT and high-frequency EUS were used to visualize laryngeal tumors in the area of protruding mass formation in four rabbits, one week after injection (group A) and the remaining four rabbits two weeks after injection (group B). Results: A small submucosal tumor was observed with rigid laryngoscopy in group A, and pathologic evaluation showed that the tumor was close to the basement membrane of the vocal fold mucosa, but had not invaded. OCT confirmed that the lining of the mucosa and basement membrane of the vocal fold was not broken, but the mucosa had thinned at the most elevated ridge. However, these lesions were not detected by EUS, and the overall shape of the tumor could not be clearly identified by EUS. A large tumor filling the laryngeal lumen was observed with rigid laryngoscopy in group B, and nearly the entire vocal fold, including the paraglottic space, was found to be involved on pathologic analysis. Distinguishing between normal structures and tumor was difficult using OCT; however, EUS confirmed the overall shape, size, and extent of the tumor, and the paraglottic space and thyroid cartilage were shown to be intact. Conclusions: This study is the first experimental trial, assessing the value of multimodal imaging using OCT and EUS in a rabbit VX2 laryngeal tumor model. Combining OCT and EUS helped to identify changes in laryngeal mucous membranes, and could potentially be used to identify laryngeal tumors and predict how tumors progress. This combined modality could help in determining tumor extent, assisting in diagnosis, and establishing a treatment plan for laryngeal cancer. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:704 / 710
页数:7
相关论文
共 50 条
  • [41] Using semi-quantitative dynamic contrast-enhanced magnetic resonance imaging parameters to evaluate tumor hypoxia: a preclinical feasibility study in a maxillofacial VX2 rabbit model
    Zheng, Linfeng
    Li, Yujie
    Geng, Feng
    Zheng, Sujuan
    Yan, Ruiling
    Han, Yuedong
    Wang, Qiben
    Zhang, Zhuoli
    Zhang, Guixiang
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2015, 7 (03): : 535 - 547
  • [42] Evaluation of neovascularization with spectral computed tomography in a rabbit VX2 liver model: a comparison with real-time contrast-enhanced ultrasound and molecular biological findings
    Zhou, Yue
    Gao, Jian-Bo
    Xu, Han
    Dong, Jun-Qiang
    Wang, Ming-Yue
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1055)
  • [43] Monitoring of VX2 Tumor Growth in Rabbit Liver Using T2-weighted and Dynamic Contrast-Enhanced Magnetic Resonance Imaging at 1.5T
    Jao, Jo-Chi
    Mac, Ka-Wai
    Chang, Chiung-Yun
    Wu, Yu-Chiuan
    Hsiao, Chia-Chi
    Chen, Po-Chou
    MEDICAL IMAGING 2017: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2017, 10137
  • [44] Multimodal fluorescence lifetime imaging and optical coherence tomography for longitudinal monitoring of tissue-engineered cartilage maturation in a preclinical implantation model
    Zhou, Xiangnan
    Haudenschild, Anne K.
    Li, Cai
    Marcu, Laura
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (02)
  • [45] Cellular Imaging Using Equivalent Cross-Relaxation Rate Technique in Rabbit VX-2 Tumor Model
    Nishiofuku, Hideyuki
    Matsushima, Shigeru
    Taguchi, Osamu
    Inaba, Yoshitaka
    Yamaura, Hidekazu
    Sato, Yozo
    Tanaka, Toshihiro
    Kichikawa, Kimihiko
    CANCER INFORMATICS, 2011, 10 : 227 - 232
  • [46] Explainable AI based efficient ensemble model for breast cancer classification using optical coherence tomography
    Dhiman, Babita
    Kamboj, Sangeeta
    Srivastava, Vishal
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 91
  • [47] Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin-equivalent tissue model
    Yeh, AT
    Kao, BS
    Jung, WG
    Chen, ZP
    Nelson, JS
    Tromberg, BJ
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) : 248 - 253
  • [48] Intravoxel incoherent motion diffusion-weighted imaging and shear wave elastography for evaluating peritumoral liver fibrosis after transarterial chemoembolization in a VX2 rabbit liver tumor model
    Cheng, Zhimei
    Yang, Qin
    He, Huizhou
    Li, Ran
    Li, Xueying
    Jiang, Hongyu
    Zhao, Xuya
    Li, Junxiang
    Wang, Lizhou
    Zhou, Shi
    Zhang, Shuai
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [49] Internal physiology of live krill revealed using new aquaria techniques and mixed optical microscopy and optical coherence tomography ( OCT) imaging techniques
    Cox, Martin
    Kawaguchi, So
    King, Robert
    Dholakia, Kishan
    Brown, Christian T. A.
    MARINE AND FRESHWATER BEHAVIOUR AND PHYSIOLOGY, 2015, 48 (06) : 455 - 466
  • [50] In Vivo Scoring of the Endotoxin-Induced Uveitis Model using Optical Coherence Tomography: Comparison with Fundus Imaging and Histology.
    Rageh, Abrar A.
    Roehrich, Heidi
    Abdullah, Selwan
    Burckhard, Braden
    Ferrington, Deborah A.
    Montezuma, Sandra
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)