Multimodal Imaging Using Optical Coherence Tomography and Endolaryngeal Ultrasonography in a New Rabbit VX2 Laryngeal Cancer Model

被引:7
作者
Oak, Chulho [1 ,2 ]
Ahn, Yeh-Chan [1 ,3 ,4 ]
Nam, Sung-Jin [1 ,2 ]
Jung, Maan Hong [1 ,2 ]
Hwang, Sang Seok [1 ,3 ,4 ]
Chae, Yu-Gyeong [1 ,3 ,4 ]
Lee, Hyoung Shin [1 ,5 ]
Lee, Kang Dae [1 ,5 ]
Jung, Min Jung [1 ,6 ]
Chun, Bong Kwon [1 ,6 ]
Lee, Hae Young [1 ,7 ]
Park, Eun-Kee [1 ,8 ]
Kim, Sung Won [1 ,5 ]
机构
[1] Innovat Biomed Technol Res Ctr, Busan 602030, South Korea
[2] Kosin Univ, Coll Med, Dept Internal Med, Busan 602030, South Korea
[3] Pukyong Natl Univ, Dept Biomed Engn, Busan 608737, South Korea
[4] Pukyong Natl Univ, Ctr Marine Integrated Biomed Technol, Busan 608737, South Korea
[5] Kosin Univ, Dept Otolaryngol Head & Neck Surg, Coll Med, Busan 602030, South Korea
[6] Kosin Univ, Dept Pathol, Coll Med, Busan 602030, South Korea
[7] Kosin Univ, Dept Thorac & Cardiovasc Surg, Coll Med, Busan 602030, South Korea
[8] Kosin Univ, Dept Med Humanities & Social Med, Coll Med, Busan 602030, South Korea
基金
新加坡国家研究基金会;
关键词
optical coherence tomography; endolaryngeal ultrasonography; vocal fold; laryngeal cancer; CLINICAL-VALUE; TUMOR; ULTRASOUND; MARGINS;
D O I
10.1002/lsm.22409
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and Objective: Optical coherence tomography (OCT) provides ultrahigh-resolution imaging of tissues within a depth of a few millimeters, whereas ultrasonography provides good imaging further below the surface. We aimed to develop a minimally invasive rabbit model of VX2 laryngeal cancer, suitable for these two imaging modalities through a transoral approach. We also sought to study the utility of combined OCT and endolaryngeal ultrasonography (EUS) for evaluation of early and advanced laryngeal cancer, using this model. Materials and Methods: VX2 tumor suspension was inoculated into the vocal folds of ten rabbits by injection through the trans-thyrohyoid membrane. The tumor model was characterized by rigid laryngoscopy and the tumor generation rate was 80% (8/10). Correlation between frequency-domain OCT and high-frequency EUS were used to visualize laryngeal tumors in the area of protruding mass formation in four rabbits, one week after injection (group A) and the remaining four rabbits two weeks after injection (group B). Results: A small submucosal tumor was observed with rigid laryngoscopy in group A, and pathologic evaluation showed that the tumor was close to the basement membrane of the vocal fold mucosa, but had not invaded. OCT confirmed that the lining of the mucosa and basement membrane of the vocal fold was not broken, but the mucosa had thinned at the most elevated ridge. However, these lesions were not detected by EUS, and the overall shape of the tumor could not be clearly identified by EUS. A large tumor filling the laryngeal lumen was observed with rigid laryngoscopy in group B, and nearly the entire vocal fold, including the paraglottic space, was found to be involved on pathologic analysis. Distinguishing between normal structures and tumor was difficult using OCT; however, EUS confirmed the overall shape, size, and extent of the tumor, and the paraglottic space and thyroid cartilage were shown to be intact. Conclusions: This study is the first experimental trial, assessing the value of multimodal imaging using OCT and EUS in a rabbit VX2 laryngeal tumor model. Combining OCT and EUS helped to identify changes in laryngeal mucous membranes, and could potentially be used to identify laryngeal tumors and predict how tumors progress. This combined modality could help in determining tumor extent, assisting in diagnosis, and establishing a treatment plan for laryngeal cancer. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:704 / 710
页数:7
相关论文
共 50 条
  • [21] Multimodal endoscopy for colorectal cancer detection by optical coherence tomography and near-infrared fluorescence imaging
    Li, Yan
    Zhu, Zhikai
    Chen, Jason J.
    Jing, Joseph C.
    Sun, Chung-Ho
    Kim, Sehwan
    Chung, Phil-Sang
    Chen, Zhongping
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (05) : 2419 - 2429
  • [22] Contrast Agent Enhanced Multimodal Photoacoustic Microscopy and Optical Coherence Tomography for Imaging of Rabbit Choroidal and Retinal Vessels in vivo
    Van Phuc Nguyen
    Li, Yanxiu
    Qian, Wei
    Liu, Bing
    Tian, Chao
    Zhang, Wei
    Huang, Ziyi
    Henry, Jessica
    Rosen, Rachel
    Aaberg, Micheal
    Ponduri, Arjun
    Tarnowski, Madison
    Wang, Xueding
    Paulus, Yannis M.
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC AND SURGICAL GUIDANCE SYSTEMS XVII, 2019, 10868
  • [23] In Vivo 3D Imaging of Retinal Neovascularization Using Multimodal Photoacoustic Microscopy and Optical Coherence Tomography Imaging
    Van Phuc Nguyen
    Li, Yanxiu
    Aaberg, Michael
    Zhang, Wei
    Wang, Xueding
    Paulus, Yannis M.
    JOURNAL OF IMAGING, 2018, 4 (12):
  • [24] Dynamics of angiogenesis and cellularity in rabbit VX2 tumors using contrast-enhanced magnetic resonance imaging and diffusion-weighted imaging
    Li, Haixia
    Yu, Lijuan
    Wang, Wenzhi
    Wang, Lingling
    Zheng, Xiulan
    Dai, Shaochun
    Sun, Yanqin
    ONCOLOGY LETTERS, 2018, 15 (03) : 2978 - 2984
  • [25] Diagnosis of Subglottic Stenosis in a Rabbit Model Using Long-Range Optical Coherence Tomography
    Ajose-Popoola, Olubunmi
    Su, Erica
    Hamamoto, Ashley
    Wang, Alex
    Jing, Joseph C.
    Nguyen, Tony D.
    Chen, Jason J.
    Osann, Kathryn E.
    Chen, Zhongping
    Ahuja, Gurpreet S.
    Wong, Brian J. F.
    LARYNGOSCOPE, 2017, 127 (01) : 64 - 69
  • [26] Ultrasound-Guided Percutaneous Microwave Coagulation Studies on VX2 Rabbit Models for Breast Cancer Treatment and Ultrasound Imaging Assessment
    Gao, Qi
    Huang, Hu
    Shi, Jin-Jun
    Wang, Ling
    Li, Wei-Min
    BREAST CANCER-TARGETS AND THERAPY, 2025, 17 : 241 - 252
  • [27] Enhanced detection of early-stage oral cancer in vivo by optical coherence tomography using multimodal delivery of gold nanoparticles
    Kim, Chang Soo
    Wilder-Smith, Petra
    Ahn, Yeh-Chan
    Liaw, Lih-Huei L.
    Chen, Zhongping
    Kwon, Young Jik
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
  • [28] Multimodal ophthalmic imaging using swept source spectrally encoded scanning laser ophthalmoscopy and optical coherence tomography
    Malone, Joseph D.
    El-Haddad, Mohamed T.
    Tye, Logan A.
    Majeau, Lucas
    Godbout, Nicolas
    Rollins, Andrew M.
    Boudoux, Caroline
    Tao, Yuankai K.
    OPHTHALMIC TECHNOLOGIES XXVI, 2016, 9693
  • [29] Development of a Hepatic VX2 carcinoma model in rabbits using an improved minimally invasive method and evaluation with imaging examinations
    Yuan, Gang
    Xu, Yanneng
    Wang, Yunqiao
    Zhang, Xun
    Wang, Weiming
    He, Yanzheng
    Zhu, Xiaoming
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2022, 18 (07) : 1973 - 1980
  • [30] The efficacy of 99mTc-MIBI imaging in 125I seed implantation treatment of rabbit VX2 transplanted liver cancer
    Wang, Xufu
    Hu, Xiaokun
    Liu, Xinfeng
    Peng, Lijing
    Wang, Zenghua
    Wang, Guoqiang
    Wang, Guoming
    Zhang, Qin
    Han, Jiankui
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2019, 12 (06): : 2363 - 2367