Electric resistance variation of packing materials in capillary electrochromatography by using fluorinated-bonded silica and octadecylsilane phases

被引:4
作者
Chaiyasut, C
Kitagawa, S
Wada, H
Tsuda, T [1 ]
机构
[1] Nagoya Inst Technol, Dept Appl Chem, Showa Ku, Nagoya, Aichi 4668555, Japan
[2] Nagoya Inst Technol, Venture Business Lab, Showa Ku, Nagoya, Aichi 4668555, Japan
关键词
D O I
10.2116/analsci.16.413
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The linear relationship between electric resistance of the packed column for capillary electrochromatography and applied voltage was observed in several different effluents and packing materials (fluorinated-bonded silica and octahecylsilane). These linear relationships had different slope values which depended on the charges on the surface of the stationary phase. If there are the negative charges on the stationary phase during the application of the electric field, the slope was negative value as observed in the fluorinated-bonded silica packed column. On the other hand, the slope was positive value in the fluorinated-bonded silica packed column using 0.1% tetrabutyammonium chloride as an effluent. The inclination of the linear relationship between the electric resistance and applied voltage also depended on the kind of the effluent, the concentration of effluent and the ratio of the organic modifier used. In the case of octadecylsilane packed column, the electric resistance of the column did not depend on the applied voltage. The relationship between the electric resistance and the electroosmotic mobility was also studied.
引用
收藏
页码:413 / 416
页数:4
相关论文
共 13 条
[1]  
Chaiyasut C, 1999, J MICROCOLUMN SEP, V11, P590, DOI 10.1002/(SICI)1520-667X(1999)11:8<590::AID-MCS4>3.3.CO
[2]  
2-7
[3]   PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS [J].
EIMER, T ;
UNGER, KK ;
TSUDA, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :649-653
[4]  
Kitagawa S, 1997, J MICROCOLUMN SEP, V9, P347, DOI 10.1002/(SICI)1520-667X(1997)9:5<347::AID-MCS2>3.0.CO
[5]  
2-1
[6]  
Kitagawa S, 1999, ELECTROPHORESIS, V20, P9, DOI 10.1002/(SICI)1522-2683(19990101)20:1<9::AID-ELPS9>3.0.CO
[7]  
2-6
[8]   EFFECTS OF PH AND ORGANIC-SOLVENT ON CHROMATOGRAPHIC BEHAVIOR IN CAPILLARY ELECTROCHROMATOGRAPHY [J].
KITAGAWA, S ;
TSUDA, T .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (02) :91-96
[9]   Voltage-induced sample release from anion exchange supports in capillary electrochromatography [J].
Kitagawa, S ;
Tsuda, T .
ANALYTICAL SCIENCES, 1998, 14 (03) :571-575
[10]   ELECTROOSMOTICALLY DRIVEN ELECTROCHROMATOGRAPHY OF ANIONS HAVING SIMILAR ELECTROPHORETIC MOBILITIES BY ION-PAIRING [J].
PFEFFER, WD ;
YEUNG, ES .
JOURNAL OF CHROMATOGRAPHY, 1991, 557 (1-2) :125-136