Extravascular density model for PET partial volume correction

被引:0
|
作者
Wassenaar, Richard W. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Carleton Univ, Ottawa, ON K1S 5B6, Canada
关键词
POSITRON-EMISSION; STRATEGY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate quantification of F-18-FDG myocardial uptake values can be complicated by partial volume losses (PV). The use of an extravascular (EV) density image has been proposed as a means of correcting for PV losses in the left ventricle (LV) myocardium. The EV image, initially developed for lung density measurements, is created by subtracting a blood pool image from a transmission image. Within the myocardial wall, the EV values represent the mass of tissue present for tracer uptake. Increased PV losses correspond to decreased EV values. Division of the regional myocardial (MYO) values by the corresponding EV values should yield PV-free MYO estimates. As well as motion- and resolution-based PV losses, the EV value also removes the effects of the vascular component in the myocardial wall. In this paper, the EV model is developed mathematically and the assumptions of the model are discussed. Simulations performed to validate the model, indicated that the EV values could exactly estimate PV losses, under ideal conditions. However, a 2 mm difference between emission and transmission resolution was found to bias the EV value by similar to 5%. As well, transmission and activity spillover from organs adjacent to the LV myocardium violated the assumptions of the model leading to as much as a 15% underestimation of the corrected activity in the anterior and inferior walls. It was found that endocardial placement of the ROls used to determine MYO and EV values minimized the effect of this spillover.
引用
收藏
页码:1809 / 1813
页数:5
相关论文
共 50 条
  • [41] FDG PET imaging and partial volume correction in the assessment of pulmonary nodules
    Alkhawaldeh, K. M.
    Dadparvar, S.
    Bural, G.
    Houseni, M.
    El-Haddad, G.
    Alavi, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S108 - S108
  • [42] Impact of partial volume correction on serial PET FDG for therapy monitoring
    Sprung, Elisheva
    Klein, Martine
    Chisin, Roland
    Freedman, Nanette
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [43] Analysis of partial volume correction on quantification and regional heterogeneity in cardiac PET
    A. Turco
    J. Nuyts
    J. Duchenne
    O. Gheysens
    J. U. Voigt
    P. Claus
    K. Vunckx
    Journal of Nuclear Cardiology, 2020, 27 : 62 - 70
  • [44] Investigation of partial volume correction methods for brain FDG PET studies
    Yang, J
    Huang, SC
    Mega, M
    Lin, KP
    Toga, AW
    Small, GW
    Phelps, ME
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3322 - 3327
  • [45] Evaluation of the Benefit of Partial Volume Correction for High Resolution PET Scanners
    Raptis, Evangelos
    Parkes, Laura M.
    Anton-Rodriguez, Jose M.
    Carter, Stephen F.
    Herholz, Karl
    Matthews, Julian C.
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [46] Importance of correction for the partial volume effect in lung cancer PET studies
    Pournazari, Kamyar
    Jahangiri, Pegah
    Saboury, Babak
    Khosravi, Mohsen
    Al-zaghal, Abdullah
    Torigian, Drew
    Alavi, Abass
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [47] A Comparison of the Options for Brain Partial Volume Correction Using PET/MRI
    Thomas, Benjamin A.
    Erlandsson, Kjell
    Reilhac, Anthonin
    Bousse, Alexandre
    Kazantsev, Daniil
    Pedemonte, Stefano
    Vunckx, Kathleen
    Arridge, Simon
    Ourselin, Sebastien
    Hutton, Brian F.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2902 - 2906
  • [48] Accuracy and precision of partial volume correction in oncological PET/CT studies
    Cysouw, Matthijs
    Kramer, Gem
    Hoekstra, Otto
    Frings, Virginie
    de Langen, Joop
    Smit, E.
    Van den Eertwegh, Alfons
    Oprea-Lager, Daniela
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [49] MR Imaging-Guided Partial Volume Correction of PET Data in PET/MR Imaging
    Erlandsson, Kjell
    Dickson, John
    Arridge, Simon
    Atkinson, David
    Ourselin, Sebastien
    Hutton, Brian F.
    PET CLINICS, 2016, 11 (02) : 161 - +
  • [50] Standardization of dual point FDG-PET with different PET scanners by partial volume correction
    Mikasa, Shohei
    Akamatsu, Go
    Taniguchi, Takafumi
    Kidera, Daisuke
    Kihara, Ken
    Matsuoka, Kohki
    Amakusa, Shinji
    Yoshida, Tsuyoshi
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54