Extravascular density model for PET partial volume correction

被引:0
|
作者
Wassenaar, Richard W. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Carleton Univ, Ottawa, ON K1S 5B6, Canada
关键词
POSITRON-EMISSION; STRATEGY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate quantification of F-18-FDG myocardial uptake values can be complicated by partial volume losses (PV). The use of an extravascular (EV) density image has been proposed as a means of correcting for PV losses in the left ventricle (LV) myocardium. The EV image, initially developed for lung density measurements, is created by subtracting a blood pool image from a transmission image. Within the myocardial wall, the EV values represent the mass of tissue present for tracer uptake. Increased PV losses correspond to decreased EV values. Division of the regional myocardial (MYO) values by the corresponding EV values should yield PV-free MYO estimates. As well as motion- and resolution-based PV losses, the EV value also removes the effects of the vascular component in the myocardial wall. In this paper, the EV model is developed mathematically and the assumptions of the model are discussed. Simulations performed to validate the model, indicated that the EV values could exactly estimate PV losses, under ideal conditions. However, a 2 mm difference between emission and transmission resolution was found to bias the EV value by similar to 5%. As well, transmission and activity spillover from organs adjacent to the LV myocardium violated the assumptions of the model leading to as much as a 15% underestimation of the corrected activity in the anterior and inferior walls. It was found that endocardial placement of the ROls used to determine MYO and EV values minimized the effect of this spillover.
引用
收藏
页码:1809 / 1813
页数:5
相关论文
共 50 条
  • [21] Correction of partial volume effects for PET imaging: a comparison study
    Kops, ER
    Reilhac, A
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4125 - 4126
  • [22] A simple method for partial volume effect correction in PET images
    Department of Nuclear Medicine, General Hospital of PLA, Beijing 100853, China
    不详
    Hedianzixue Yu Tance Jishue, 2007, 6 (1231-1238): : 1231 - 1238
  • [23] Partial volume correction of lung nodules using PET/CT
    Bradley, W.
    Wendt, R.
    Pan, T.
    Erasmus, J.
    White, R.
    Mawlawi, O.
    MEDICAL PHYSICS, 2007, 34 (06) : 2553 - 2553
  • [24] Correction for partial volume effect in PET blood flow images
    Gage, HD
    Fahey, FH
    Santago, P
    Harkness, BA
    Keyes, JW
    MEDICAL IMAGING 1996: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1996, 2709 : 244 - 253
  • [25] Importance of partial-volume correction in brain PET studies
    Fazio, F
    Perani, D
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1849 - 1850
  • [26] Partial volume correction strategies for quantitative FDG PET in oncology
    Hoetjes, Nikie
    Lammertsma, Adriaan
    Hoekstra, Otto
    Hoekstra, Corneline
    Krak, Nanda
    Boellaard, Ronald
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [27] Towards optimal model-based partial volume effect correction in oncological PET imaging
    Schoenahl, F
    Zaidi, H
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3177 - 3181
  • [28] Assessing neuronal density in peri-infarct cortex with PET: Effects of cortical topology and partial volume correction
    Funck, Thomas
    Al-Kuwaiti, Mohammed
    Lepage, Claude
    Zepper, Peter
    Minuk, Jeffrey
    Schipper, Hyman M.
    Evans, Alan C.
    Thiel, Alexander
    HUMAN BRAIN MAPPING, 2017, 38 (01) : 326 - 338
  • [29] Partial-Volume Effect and a Partial-Volume Correction for the NanoPET/CT™ Preclinical PET/CT Scanner
    Szanda, Istvan
    Livieratos, Lefteris
    Patay, Gergely
    Tsoumpas, Charalampos
    Sunassee, Kavitha
    Mullen, Gregory E.
    Nemeth, Gabor
    Major, Peter
    Marsden, Paul K.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3605 - 3609
  • [30] 3D Model-based partial volume correction for cardiac PET imaging in mice
    Dumouchel, Tyler
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52