Extravascular density model for PET partial volume correction

被引:0
|
作者
Wassenaar, Richard W. [1 ]
deKemp, Robert A. [1 ]
机构
[1] Carleton Univ, Ottawa, ON K1S 5B6, Canada
关键词
POSITRON-EMISSION; STRATEGY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate quantification of F-18-FDG myocardial uptake values can be complicated by partial volume losses (PV). The use of an extravascular (EV) density image has been proposed as a means of correcting for PV losses in the left ventricle (LV) myocardium. The EV image, initially developed for lung density measurements, is created by subtracting a blood pool image from a transmission image. Within the myocardial wall, the EV values represent the mass of tissue present for tracer uptake. Increased PV losses correspond to decreased EV values. Division of the regional myocardial (MYO) values by the corresponding EV values should yield PV-free MYO estimates. As well as motion- and resolution-based PV losses, the EV value also removes the effects of the vascular component in the myocardial wall. In this paper, the EV model is developed mathematically and the assumptions of the model are discussed. Simulations performed to validate the model, indicated that the EV values could exactly estimate PV losses, under ideal conditions. However, a 2 mm difference between emission and transmission resolution was found to bias the EV value by similar to 5%. As well, transmission and activity spillover from organs adjacent to the LV myocardium violated the assumptions of the model leading to as much as a 15% underestimation of the corrected activity in the anterior and inferior walls. It was found that endocardial placement of the ROls used to determine MYO and EV values minimized the effect of this spillover.
引用
收藏
页码:1809 / 1813
页数:5
相关论文
共 50 条
  • [1] Phantom studies investigating extravascular density imaging for partial volume correction of 3-D PET 18FDG studies
    Wassenaar, RW
    Beanlands, RSB
    DeKemp, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 68 - 71
  • [2] Phantom studies investigating extravascular density imaging for partial volume correction of 3D PET 18FDG studies
    Wassenaar, RW
    Beanlands, RSB
    deKemp, RA
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 821 - 824
  • [3] Partial Volume Correction Strategies in PET
    Rousset, Olivier
    Rahmim, Arman
    Alavi, Abass
    Zaidi, Habib
    PET CLINICS, 2007, 2 (02) : 235 - 249
  • [4] A method for model-free partial volume correction in oncological PET
    Frank Hofheinz
    Jens Langner
    Jan Petr
    Bettina Beuthien-Baumann
    Liane Oehme
    Jörg Steinbach
    Jörg Kotzerke
    Jörg van den Hoff
    EJNMMI Research, 2
  • [5] A method for model-free partial volume correction in oncological PET
    Hofheinz, Frank
    Langner, Jens
    Petr, Jan
    Beuthien-Baumann, Bettina
    Oehme, Liane
    Steinbach, Joerg
    Kotzerke, Joerg
    van den Hoff, Joerg
    EJNMMI RESEARCH, 2012, 2
  • [6] PET quantification: Strategies for partial volume correction
    Bettinardi V.
    Castiglioni I.
    De Bernardi E.
    Gilardi M.C.
    Clinical and Translational Imaging, 2014, 2 (3) : 199 - 218
  • [7] Diffpvc: A Conditional Diffusion Model for Partial Volume Correction in Brain PET Imaging
    Sun, Y.
    Mawlawi, O. R.
    MEDICAL PHYSICS, 2024, 51 (10) : 7894 - 7894
  • [8] Towards Uncertainty Estimation in PET Partial Volume Correction with a Diffusion Probabilistic Model
    Sun, Y.
    Mawlawi, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S133 - S134
  • [9] Partial volume correction for PET synaptic density imaging with 11C-UCB-J
    Lu, Yihuan
    Toyonaga, Takuya
    Naganawa, Mika
    Gallezot, Jean-Dominique
    Chen, Ming-Kai
    Mecca, Adam
    van Dyck, Christopher
    Carson, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [10] Correction of partial volume effect in the projections in PET studies
    Guillette, Nicolas
    Sarrhini, Otman
    Lecomte, Roger
    Bentourkia, M'hamed
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3541 - 3543