共 34 条
Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors
被引:14
作者:
Lekadir, Karim
[1
,2
]
Noble, Christopher
[1
,3
]
Hazrati-Marangalou, Javad
[5
]
Hoogendoorn, Corn
[1
,2
]
van Rietbergen, Bert
[5
]
Taylor, Zeike A.
[1
,3
]
Frangi, Alejandro F.
[1
,4
]
机构:
[1] Univ Sheffield, Ctr Computat Imaging & Simulat Technol Biomed, Sheffield, S Yorkshire, England
[2] Univ Pompeu Fabra, Dept Informat & Commun Technol, Barcelona, Spain
[3] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[5] Eindhoven Univ, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands
关键词:
Bone fracture;
Finite element methods;
Bone microarchitecture;
Statistical predictive models;
Fracture load estimation;
FINITE-ELEMENT-ANALYSIS;
QUANTITATIVE COMPUTED-TOMOGRAPHY;
STRUCTURAL ANISOTROPY;
SIDEWAYS FALL;
LOAD-TRANSFER;
MICRO-CT;
FRACTURE;
MICROARCHITECTURE;
FAILURE;
ARCHITECTURE;
D O I:
10.1007/s10439-015-1432-2
中图分类号:
R318 [生物医学工程];
学科分类号:
0831 ;
摘要:
Low trauma fractures are amongst the most frequently encountered problems in the clinical assessment and treatment of bones, with dramatic health consequences for individuals and high financial costs for health systems. Consequently, significant research efforts have been dedicated to the development of accurate computational models of bone biomechanics and strength. However, the estimation of the fabric tensors, which describe the microarchitecture of the bone, has proven to be challenging using in vivo imaging. On the other hand, existing research has shown that isotropic models do not produce accurate predictions of stress states within the bone, as the material properties of the trabecular bone are anisotropic. In this paper, we present the first biomechanical study that uses statistically-derived fabric tensors for the estimation of bone strength in order to obtain patient-specific results. We integrate a statistical predictive model of trabecular bone microarchitecture previously constructed from a sample of ex vivo micro-CT datasets within a biomechanical simulation workflow. We assess the accuracy and flexibility of the statistical approach by estimating fracture load for two different databases and bone sites, i.e., for the femur and the T12 vertebra. The results obtained demonstrate good agreement between the statistically-driven and micro-CT-based estimates, with concordance coefficients of 98.6 and 95.5% for the femur and vertebra datasets, respectively.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 34 条