Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors

被引:14
作者
Lekadir, Karim [1 ,2 ]
Noble, Christopher [1 ,3 ]
Hazrati-Marangalou, Javad [5 ]
Hoogendoorn, Corn [1 ,2 ]
van Rietbergen, Bert [5 ]
Taylor, Zeike A. [1 ,3 ]
Frangi, Alejandro F. [1 ,4 ]
机构
[1] Univ Sheffield, Ctr Computat Imaging & Simulat Technol Biomed, Sheffield, S Yorkshire, England
[2] Univ Pompeu Fabra, Dept Informat & Commun Technol, Barcelona, Spain
[3] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[5] Eindhoven Univ, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands
关键词
Bone fracture; Finite element methods; Bone microarchitecture; Statistical predictive models; Fracture load estimation; FINITE-ELEMENT-ANALYSIS; QUANTITATIVE COMPUTED-TOMOGRAPHY; STRUCTURAL ANISOTROPY; SIDEWAYS FALL; LOAD-TRANSFER; MICRO-CT; FRACTURE; MICROARCHITECTURE; FAILURE; ARCHITECTURE;
D O I
10.1007/s10439-015-1432-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Low trauma fractures are amongst the most frequently encountered problems in the clinical assessment and treatment of bones, with dramatic health consequences for individuals and high financial costs for health systems. Consequently, significant research efforts have been dedicated to the development of accurate computational models of bone biomechanics and strength. However, the estimation of the fabric tensors, which describe the microarchitecture of the bone, has proven to be challenging using in vivo imaging. On the other hand, existing research has shown that isotropic models do not produce accurate predictions of stress states within the bone, as the material properties of the trabecular bone are anisotropic. In this paper, we present the first biomechanical study that uses statistically-derived fabric tensors for the estimation of bone strength in order to obtain patient-specific results. We integrate a statistical predictive model of trabecular bone microarchitecture previously constructed from a sample of ex vivo micro-CT datasets within a biomechanical simulation workflow. We assess the accuracy and flexibility of the statistical approach by estimating fracture load for two different databases and bone sites, i.e., for the femur and the T12 vertebra. The results obtained demonstrate good agreement between the statistically-driven and micro-CT-based estimates, with concordance coefficients of 98.6 and 95.5% for the femur and vertebra datasets, respectively.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 34 条
  • [31] Analyzing bone remodeling patterns after total hip arthroplasty using quantitative computed tomography and patient-specific 3D computational models
    Arachchi, Shanika
    Pitto, Rocco P.
    Anderson, Iain A.
    Shim, Vickie B.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2015, 5 (04) : 575 - 582
  • [32] Patient-Specific Finite Element Modeling of the Whole Lumbar Spine Using Clinical Routine Multi-Detector Computed Tomography (MDCT) Data-A Pilot Study
    Rayudu, Nithin Manohar
    Subburaj, Karupppasamy
    Mohan, Rajesh Elara
    Sollmann, Nico
    Dieckmeyer, Michael
    Kirschke, Jan S.
    Baum, Thomas
    BIOMEDICINES, 2022, 10 (07)
  • [33] Patient-specific bone mineral density distribution in the tibia of individuals with chronic spinal cord injury, derived from multi-slice peripheral Quantitative Computed Tomography (pQCT) - A cross-sectional study
    Coupaud, Sylvie
    Gislason, Magnus K.
    Purcell, Mariel
    Sasagawa, Keisuke
    Tanner, K. Elizabeth
    BONE, 2017, 97 : 29 - 37
  • [34] Comparison of the biomechanical behavior between commercial and 3D-printed patient-specific Ti6Al4V L-Shaped titanium plates following le fort i osteotomy using finite element analysis: A technical Note
    Telha, Wael
    Chen, Haozhe
    Al-Watary, Mohammed Qasem
    Sakran, Karim
    Wang, Qi
    Zhu, Songsong
    Jiang, Nan
    MEDICAL ENGINEERING & PHYSICS, 2024, 129