Patient-Specific Biomechanical Modeling of Bone Strength Using Statistically-Derived Fabric Tensors

被引:14
作者
Lekadir, Karim [1 ,2 ]
Noble, Christopher [1 ,3 ]
Hazrati-Marangalou, Javad [5 ]
Hoogendoorn, Corn [1 ,2 ]
van Rietbergen, Bert [5 ]
Taylor, Zeike A. [1 ,3 ]
Frangi, Alejandro F. [1 ,4 ]
机构
[1] Univ Sheffield, Ctr Computat Imaging & Simulat Technol Biomed, Sheffield, S Yorkshire, England
[2] Univ Pompeu Fabra, Dept Informat & Commun Technol, Barcelona, Spain
[3] Univ Sheffield, Dept Mech Engn, Sheffield, S Yorkshire, England
[4] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[5] Eindhoven Univ, Dept Biomed Engn, Orthopaed Biomech, Eindhoven, Netherlands
关键词
Bone fracture; Finite element methods; Bone microarchitecture; Statistical predictive models; Fracture load estimation; FINITE-ELEMENT-ANALYSIS; QUANTITATIVE COMPUTED-TOMOGRAPHY; STRUCTURAL ANISOTROPY; SIDEWAYS FALL; LOAD-TRANSFER; MICRO-CT; FRACTURE; MICROARCHITECTURE; FAILURE; ARCHITECTURE;
D O I
10.1007/s10439-015-1432-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Low trauma fractures are amongst the most frequently encountered problems in the clinical assessment and treatment of bones, with dramatic health consequences for individuals and high financial costs for health systems. Consequently, significant research efforts have been dedicated to the development of accurate computational models of bone biomechanics and strength. However, the estimation of the fabric tensors, which describe the microarchitecture of the bone, has proven to be challenging using in vivo imaging. On the other hand, existing research has shown that isotropic models do not produce accurate predictions of stress states within the bone, as the material properties of the trabecular bone are anisotropic. In this paper, we present the first biomechanical study that uses statistically-derived fabric tensors for the estimation of bone strength in order to obtain patient-specific results. We integrate a statistical predictive model of trabecular bone microarchitecture previously constructed from a sample of ex vivo micro-CT datasets within a biomechanical simulation workflow. We assess the accuracy and flexibility of the statistical approach by estimating fracture load for two different databases and bone sites, i.e., for the femur and the T12 vertebra. The results obtained demonstrate good agreement between the statistically-driven and micro-CT-based estimates, with concordance coefficients of 98.6 and 95.5% for the femur and vertebra datasets, respectively.
引用
收藏
页码:234 / 246
页数:13
相关论文
共 34 条
  • [21] Finite Element Model of Patient-Specific Flanged Acetabular Components Highlights Biomechanical Effects of Bone Density and Cortical Shell Thickness
    Lee, Haena-Young
    Boettner, Friedrich
    Blevins, Jason L.
    Rodriguez, Jose A.
    Lipman, Joseph D.
    Gonzalez, Fernando J. Quevedo
    Bostrom, Mathias P.
    Wright, Timothy M.
    Sculco, Peter K.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2025, 43 (04) : 834 - 841
  • [22] Automatic mapping of atrial fiber orientations for patient-specific modeling of cardiac electromechanics using image registration
    Hoermann, Julia M.
    Pfaller, Martin R.
    Avena, Linda
    Bertoglio, Cristobal
    Wall, Wolfgang A.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (06)
  • [23] Towards patient-specific modeling of mitral valve repair: 3D transesophageal echocardiography-derived parameter estimation
    Zhang, Fan
    Kanik, Jingjing
    Mansi, Tommaso
    Voigt, Ingmar
    Sharma, Puneet
    Ionasec, Razvan Ioan
    Subrahmanyan, Lakshman
    Lin, Ben A.
    Sugeng, Lissa
    Yuh, David
    Comaniciu, Dorin
    Duncan, James
    MEDICAL IMAGE ANALYSIS, 2017, 35 : 599 - 609
  • [24] Patient-Specific Inverse Modeling of In Vivo Cardiovascular Mechanics with Medical Image-Derived Kinematics as Input Data: Concepts, Methods, and Applications
    Bracamonte, Johane H.
    Saunders, Sarah K.
    Wilson, John S.
    Truong, Uyen T.
    Soares, Joao S.
    APPLIED SCIENCES-BASEL, 2022, 12 (08):
  • [25] Patient-specific finite element modeling of respiratory lung motion using 4D CT image data
    Werner, Rene
    Ehrhardt, Jan
    Schmidt, Rainer
    Handels, Heinz
    MEDICAL PHYSICS, 2009, 36 (05) : 1500 - 1511
  • [26] Design Criteria for Patient-specific Mandibular Continuity Defect Reconstructed Implant with Lightweight Structure using Weighted Topology Optimization and Validated with Biomechanical Fatigue Testing
    Lin, Chun-Li
    Wang, Yu-Tzu
    Chang, Chun-Ming
    Wu, Cheng-Hsien
    Tsai, Wei-Heng
    INTERNATIONAL JOURNAL OF BIOPRINTING, 2022, 8 (01)
  • [27] Finite Element Modeling Using Patient-Specific Geometry to Predict Aortic Valve Insufficiency During Percutaneous Pulmonary Valve Implantation
    Donahue, Carly L.
    Aggarwal, Varun
    Barocas, Victor H.
    PROCEEDINGS OF THE 2022 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2022), 2022,
  • [28] Homogeneous and Heterogeneous Modeling of Patient-Specific Hip Implant Under Static and Dynamic Loading Condition Using Finite Element Analysis
    Ravikant
    Mittal V.K.
    Gupta V.
    Journal of The Institution of Engineers (India): Series D, 2024, 105 (01) : 1 - 20
  • [29] Ascending thoracic aortic aneurysm wall stress analysis using patient-specific finite element modeling of in vivo magnetic resonance imaging
    Krishnan, Kapil
    Ge, Liang
    Haraldsson, Henrik
    Hope, Michael D.
    Saloner, David A.
    Guccione, Julius M.
    Tseng, Elaine E.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 21 (04) : 471 - 480
  • [30] Comparing the biomechanical properties of conventional suture and all-suture anchors using patient-specific and realistic osteoporotic and non-osteoporotic phantom using 3D printing
    Ock, Junhyeok
    Seo, Junghyun
    Koh, Kyoung Hwan
    Kim, Namkug
    SCIENTIFIC REPORTS, 2023, 13 (01)