Radiopathological correlations: Masses, non-masslike enhancements and MRI-guided biopsy

被引:6
作者
Chopier, J. [1 ]
Dratwa, C. [1 ]
Antoine, M. [2 ]
Gonin, J. [2 ]
Naggara, I. Thomassin [1 ]
机构
[1] Hop Tenon, Dept Radiol, F-75020 Paris, France
[2] Hop Tenon, Dept Histopathol, F-75020 Paris, France
关键词
Breast MRI; MRI-guided biopsy; Radiopathological correlation; ASSISTED BREAST BIOPSY; FOLLOW-UP; LESIONS; BENIGN; CONCORDANT; FREQUENCY; DIAGNOSIS; UTILITY;
D O I
10.1016/j.diii.2013.12.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI-guided biopsy is a recent interventional breast technique. Validating the procedure poses a new problem because the signal targeted is created by the injection of a paramagnetic contrast agent and is thus transitory. In the first instance, the procedure is validated by the radiologist, who checks that targeting is accurate and inserts a clip at the end of the procedure, and secondly by analysis of the histopathological results, which should be representative of the lesion. The pathologist needs to know the nature of the image, i.e. whether it is of mass or non-masslike enhancement, and its BI-RADS classification. The objective is that the image and the pathological result should concur. If the result is non-specific and benign, a follow-up MRI is required six months later. (C) 2013 Editions francaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:213 / 225
页数:13
相关论文
共 31 条
[1]  
American College of Radiology (ACR), 2003, ACR Breast Imaging Reporting and Data System: Breast Imaging Atlas, V4th ed.
[2]   Papilloma Diagnosed at MRI-Guided Vacuum-Assisted Breast Biopsy: Is Surgical Excision Still Warranted? [J].
Brennan, Sandra B. ;
Corben, Adriana ;
Liberman, Laura ;
Dershaw, D. David ;
Brogi, Edi ;
Van Zee, Kimberly J. ;
Morris, Elizabeth .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (04) :W512-W519
[3]   High-risk lesions diagnosed at MRI-guided vacuum-assisted breast biopsy: can underestimation be predicted? [J].
Crystal, Pavel ;
Sadaf, Arifa ;
Bukhanov, Karina ;
McCready, David ;
O'Malley, Frances ;
Helbich, Thomas H. .
EUROPEAN RADIOLOGY, 2011, 21 (03) :582-589
[4]  
David J, 2007, IRM SEIN GYNECOLOGIE, P301
[5]   Utility of Targeted Sonography for Breast Lesions That Were Suspicious on MRI [J].
DeMartini, Wendy B. ;
Eby, Peter R. ;
Peacock, Sue ;
Lehman, Constance D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (04) :1128-1134
[6]   Differential Diagnosis of Breast Lesions 5 mm or Less: Is There a Role for Magnetic Resonance Imaging? [J].
Dietzel, Matthias ;
Baltzer, Pascal A. ;
Vag, Tibor ;
Groeschel, Tobias ;
Gajda, Mieczyslaw ;
Camara, Oumar ;
Kaiser, Werner A. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (03) :456-464
[7]   Effort, Accuracy and Histology of MR-Guided Vacuum Biopsy of Suspicious Breast Lesions - Retrospective Evaluation after 389 Interventions [J].
Fischer, U. ;
Schwethelm, L. ;
Baum, F. T. ;
Luftner-Nagel, S. ;
Teubner, J. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (08) :774-781
[8]   Magnetic resonance-guided biopsy of suspicious breast lesions with a handheld vacuum biopsy device [J].
Gebauer, B. ;
Bostanjoglo, M. ;
Moesta, K. T. ;
Schneider, W. ;
Schlag, P. M. ;
Felix, R. .
ACTA RADIOLOGICA, 2006, 47 (09) :907-913
[9]   Outcome of MRI-Guided Breast Biopsy [J].
Han, Boo-Kyung ;
Schnall, Mitchell D. ;
Orel, Susan G. ;
Rosen, Mark .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) :1798-1804
[10]   MR-guided vacuum-assisted breast biopsy with a handheld biopsy experience and results system: clinical in postinterventional MR mammography after 24 h [J].
Hauth, E. A. ;
Jaeger, H. J. ;
Lubnau, J. ;
Maderwald, S. ;
Otterbach, F. ;
Kimmig, R. ;
Forsting, M. .
EUROPEAN RADIOLOGY, 2008, 18 (01) :168-176