摘要
Monitoring cardiac output is of special interest for detecting early hemodynamic impairment and for guiding its treatment. Among the techniques that are available to monitor cardiac output, pressure waveform analysis estimates cardiac output from the shape of the arterial pressure curve. It is based on the general principle that the amplitude of the systolic part of the arterial curve is proportional to cardiac output and arterial compliance. Such an estimation of cardiac output has the advantage of being continuous and in real time. With calibrated devices, the initial estimation of cardiac output by pressure waveform analysis is calibrated by measurements of cardiac output made by transpulmonary thermal or lithium dilution. Later, at each time transpulmonary dilution is performed, the estimation by pressure waveform analysis, which may drift over time, is calibrated again. By contrast, uncalibrated devices do not use any independent measurement of cardiac output. Unlike calibrated devices, they can be plugged to any arterial catheter. Nevertheless, uncalibrated devices are not reliable in cases of significant short-term changes in arterial resistance, as for instance in patients undergoing liver surgery or those with vasodilatory shock receiving vasopressors. Perioperative hemodynamic monitoring is recommended for high-risk surgical patients since it reduces the number of complications in these patients. The pressure waveform analysis monitoring, especially with uncalibrated devices, is suitable for this purpose. In the intensive care setting, hemodynamic monitoring is recommended for patients with acute circulatory failure, who do not respond to initial therapy. Since these patients often experience large changes in arterial resistance, either spontaneously or due to vasoactive drugs, calibrated devices are more suitable in this context. Not only are they more reliable than uncalibrated devices but also they provide a comprehensive hemodynamic assessment through measurements of a variety of transpulmonary thermodilution-related variables. In this review, we summarize the characteristics of the monitoring devices using the pressure waveform analysis and discuss the appropriate use of different devices in the perioperative and intensive care unit settings.
引用
收藏
页码:1930 / 1933
页数:4
相关论文
共 15 条
  • [1] Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
    Bendjelid, K.
    Marx, G.
    Kiefer, N.
    Simon, T. P.
    Geisen, M.
    Hoeft, A.
    Siegenthaler, N.
    Hofer, C. K.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2013, 111 (04) : 573 - 579
  • [2] The effects of goal-directed fluid therapy based on dynamic parameters on post-surgical outcome: a meta-analysis of randomized controlled trials
    Benes, Jan
    Giglio, Mariateresa
    Brienza, Nicola
    Michard, Frederic
    [J]. CRITICAL CARE, 2014, 18 (05) : 1 - 11
  • [3] Noninvasive Continuous Cardiac Output by the Nexfin Before and After Preload-Modifying Maneuvers: A Comparison with Intermittent Thermodilution Cardiac Output
    Bubenek-Turconi, Serban Ion
    Craciun, Mihaela
    Miclea, Ion
    Perel, Azriel
    [J]. ANESTHESIA AND ANALGESIA, 2013, 117 (02) : 366 - 372
  • [4] Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine
    Cecconi, Maurizio
    De Backer, Daniel
    Antonelli, Massimo
    Beale, Richard
    Bakker, Jan
    Hofer, Christoph
    Jaeschke, Roman
    Mebazaa, Alexandre
    Pinsky, Michael R.
    Teboul, Jean Louis
    Vincent, Jean Louis
    Rhodes, Andrew
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 (12) : 1795 - 1815
  • [5] Continuous and intermittent cardiac output measurement in hyperdynamic conditions: pulmonary artery catheter vs. lithium dilution technique
    Costa, Maria Gabriella
    Della Rocca, Giorgio
    Chiarandini, Paolo
    Mattelig, Silvia
    Pompei, Livia
    Barriga, Mauricio Sainz
    Reynolds, Toby
    Cecconi, Maurizio
    Pietropaoli, Paolo
    [J]. INTENSIVE CARE MEDICINE, 2008, 34 (02) : 257 - 263
  • [6] Cardiac output measurement in patients undergoing liver transplantation:: Pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis
    Matthieu, Biais
    Karine, Nouette-Gaulain
    Vincent, Cottenceau
    Alain, Vallet
    Francois, Cochard Jean
    Philippe, Revel
    Francois, Sztark
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (05) : 1480 - 1486
  • [7] The Impact of Phenylephrine, Ephedrine, and Increased Preload on Third-Generation Vigileo-FloTrac and Esophageal Doppler Cardiac Output Measurements
    Meng, Lingzhong
    Nam Phuong Tran
    Alexander, Brenton S.
    Laning, Kathleen
    Chen, Guo
    Kain, Zeev N.
    Cannesson, Maxime
    [J]. ANESTHESIA AND ANALGESIA, 2011, 113 (04) : 751 - 757
  • [8] Comparison of pulse contour analysis by Pulsioflex and Vigileo to measure and track changes of cardiac output in critically ill patients
    Monnet, X.
    Vaquer, S.
    Anguel, N.
    Jozwiak, M.
    Cipriani, F.
    Richard, C.
    Teboul, J. -L.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2015, 114 (02) : 235 - 243
  • [9] Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
    Monnet, X.
    Anguel, N.
    Jozwiak, M.
    Richard, C.
    Teboul, J. -L.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (04) : 615 - 622
  • [10] MONNET X, 2017, CRIT CARE, V21