Prediction of retention factors of phenolic and nitrogen-containing compounds in reversed-phase liquid chromatography based on logP and pKa obtained by computational chemical calculation

被引:23
作者
Hanai, T [1 ]
Koizumi, K
Kinoshita, T
机构
[1] Inst Pasteur 5F, Hlth Res Fdn, Sakyo Ku, Kyoto 6068225, Japan
[2] Yokogawa Analyt Syst, Tokyo 1800006, Japan
[3] Kitasato Univ, Sch Pharmaceut Sci, Minato Ku, Tokyo 1080072, Japan
关键词
D O I
10.1081/JLC-100101457
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The new logP values (NlogP) of phenolic and nitrogen-containing compounds based on the modified CAChe(TM) MOPAC calculation improved the correlation coefficient with measured logP values (MlogP) to 0.950 from 0.662 (n = 87). The best correlation coefficient was obtained between retention factors of their molecular form and NlogP values among NlogP, CAChe logP, MOPAC-BlogP, Rekker's logP, Hansch's logP, and MlogP. Correlation coefficients were 0.880 (n = 50) for phenolic compounds and 0.900 (n = 48) for nitrogen-containing compounds. The correlation coefficients between predicted and measured maximum retention factors were 0.883 (n = 50) for phenolic compounds and 0.891 (n = 48) for nitrogen-containing compounds. Addition of pka values predicted by partial charges of atoms calculated using CAChe(TM) MOPAC to NlogP values could predict their retention factors in eluents at given pH. The correlation coefficient between predicted and measured retention factors of phenolic compounds at pH 8.49 was 0.927 (n = 20), and that of nitrogen-containing compounds at pH 4.0 was 0.833 (n = 45).
引用
收藏
页码:363 / 385
页数:23
相关论文
共 26 条
[1]  
BODER N, 1989, J AM CHEM SOC, V111, P3783
[2]   Retention of ionizable compounds on high-performance liquid chromatography -: III.: Variation of pK values of acids and pH values of buffers in acetonitrile-water mobile phases [J].
Bosch, E ;
Espinosa, S ;
Rosés, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 824 (02) :137-146
[3]   Role of stationary phase and eluent composition on the determination of log P values of N-hydroxyethylamide of aryloxyalkylen- and pyridine carboxylic acids by reversed-phase high-performance liquid chromatography [J].
Cimpan, G ;
Irimie, F ;
Gocan, S ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1998, 714 (02) :247-261
[4]   PREDICTION OF CHROMATOGRAPHIC RETENTION VALUES (R(M)) AND PARTITION-COEFFICIENTS (LOG P-OCT) USING A COMBINATION OF SEMIEMPIRICAL SELF-CONSISTENT REACTION FIELD CALCULATIONS AND NEURAL NETWORKS [J].
GRUNENBERG, J ;
HERGES, R .
JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 1995, 35 (05) :905-911
[5]   Prediction of pK(a) values of phenolic and nitrogen-containing compounds by computational chemical analysis compared to those measured by liquid chromatography [J].
Hanai, T ;
Koizumi, K ;
Kinoshita, T ;
Arora, R ;
Ahmed, F .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :55-61
[6]   STUDY OF QUALITATIVE-ANALYSIS BY LIQUID-CHROMATOGRAPHY USING POROUS POLYMER GEL [J].
HANAI, T .
CHROMATOGRAPHIA, 1979, 12 (02) :77-82
[7]   PREDICTION OF RETENTION TIME OF PHENOLS IN LIQUID-CHROMATOGRAPHY [J].
HANAI, T ;
HUBERT, J .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1983, 6 (01) :20-26
[8]   LIQUID-CHROMATOGRAPHIC BEHAVIOR OF NITROGEN-COMPOUNDS [J].
HANAI, T ;
HUBERT, J .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1985, 8 (13) :2463-2473
[9]  
Hanai T., 1991, LIQUID CHROMATOGRAPH, P21
[10]  
Hanai T., 1981, J HIGH RESOL CHROMAT, V4, P454, DOI [10.1002/jhrc.1240, DOI 10.1002/JHRC.1240]