Development and Validation of a Rapid Column-Switching High-Performance Liquid Chromatographic Method for the Determination of Lamotrigine in Human Serum

被引:1
|
作者
del Rosario Brunetto, Maria [1 ]
Contreras, Yaritza [1 ]
Delgado, Yelitza [1 ]
Gallignani, Maximo [1 ]
Manuel Estela, Jose [2 ]
Cerda Martin, Victor [2 ]
机构
[1] Univ Los Andes, Fac Ciencias, Lab Espect Mol, Dept Quim, Merida 5101 A, Venezuela
[2] Univ Islas Baleares, Fac Ciencias, Dept Quim, Palma de Mallorca, Islas Baleares, Spain
关键词
ANTIEPILEPTIC DRUGS; CAPILLARY-ELECTROPHORESIS; PLASMA-CONCENTRATIONS; EPILEPSY; PHARMACOKINETICS; CARBAMAZEPINE; ANTICONVULSANTS; METABOLITES; EXTRACTION; SAMPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes a simple and sensitive column-switching high-performance liquid chromatographic method with UV detection for the determination of Lamotrigine in 50 mu L of serum. After solid-phase extraction of Lamotrigine on an Oasis HLB extraction precolumn (20 x 3.9 mm; dp: 25 mu m), chromatographic separation was achieved at 30 degrees C on a Chromolith RP-18e column (50 mm x 4.6 mm i.d.) using a solution of 20% acetonitrile in 15 mM phosphate buffer (pH 7.0) as the mobile phase, at a flow-rate of 2.0 mL/min. The eluant was detected at 215 nm. The retention time for Lamotrigine was 1.28 min. The total analysis time was ca. 5 min. However, the overlap of sample preparation, analysis, and reconditioning of the precolumn increased the overall sample throughput to one injection every 3 min. The method was validated for system suitability, linearity, precision, accuracy, robustness, and limit of quantitation. The linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.9996. Recovery studies achieved from Lamotrigine spiked plasma samples showed values greater than 93%, demonstrating the excellent extraction efficiency of the precolumn. Intra- and inter-day precision were generally acceptable; the coefficient of variation was < 2.3% in all cases. The detection limits for Lamotrigine at a signal-to-noise ratio of 3 was 0.002 mu g/mL when a sample volume of 50 mu L was injected. However, it was possible to enhance the sensitivity further by injecting larger volumes, up to 200 mu L. The method was shown to be robust and the results were within the acceptable range. The method was successfully applied to the determination of Lamotrigine in human serum samples of patients submitted to Lamotrigine therapy.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [31] Development and validation of a high-performance liquid chromatographic method using fluorescence detection for the determination of vardenafil in small volumes of rat plasma and bile
    Cheng, Ching-Ling
    Kang, Guei-Jen
    Chou, Chen-Hsi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 222 - 229
  • [32] Development and Validation of a Micellar High-Performance Liquid Chromatographic Method for Determination of Risedronate in Raw Material and in a Pharmaceutical Formulation: Application to Stability Studies
    Walash, Mohamed
    Metwally, Mohamed
    Eid, Manal
    El-Shaheny, Rania
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (04) : 1228 - 1235
  • [33] High-performance liquid chromatographic assay for cefepime in serum
    Elkhaili, H
    Linger, L
    Monteil, H
    Jehl, F
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 690 (1-2): : 181 - 188
  • [34] Validated high performance liquid chromatographic method for simultaneous determination of phenytoin, phenobarbital and carbamazepine in human serum
    Kishore, P
    Rajnarayana, K
    Reddy, MS
    Sagar, JV
    Krishna, DR
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2003, 53 (11): : 763 - 768
  • [36] Column-switching high-performance liquid chromatographic analysis of carbamazepine and its principal metabolite in human plasma with direct sample injection using an alkyl-diol silica (ADS) precolumn
    Brunetto, MR
    Obando, MA
    Fernández, A
    Gallignani, M
    Burguera, JL
    Burguera, M
    TALANTA, 2002, 58 (03) : 535 - 542
  • [37] A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry
    Salihovic, Samira
    Karrman, Anna
    Lindstrom, Gunilla
    Lind, P. Monica
    Lind, Lars
    van Bavel, Bert
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1305 : 164 - 170
  • [38] Rapid extraction and high-performance liquid chromatographic determination of parthenolide in feverfew (Tanacetum parthenium)
    Zhou, JZ
    Kou, XL
    Stevenson, D
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1999, 47 (03) : 1018 - 1022
  • [39] Validation of a high-performance liquid chromatography method for the determination of pyridostigmine in plasma
    Panahi, Yunes
    Yousefi, Gholamhossein
    Sahebkar, Amirhossein
    Foroutan, Seyyed Mohsen
    Zarghi, Afshin
    Shafahati, Alireza
    Khoddam, Arash
    Saadat, Alireza
    ASIAN BIOMEDICINE, 2013, 7 (02) : 275 - 279
  • [40] A simple high-performance liquid chromatographic method for the determination of acyclovir in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Xiang, Bingren
    Zhan, Ying
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2008, 58 (04): : 199 - 202