Development and Validation of a Rapid Column-Switching High-Performance Liquid Chromatographic Method for the Determination of Lamotrigine in Human Serum

被引:1
|
作者
del Rosario Brunetto, Maria [1 ]
Contreras, Yaritza [1 ]
Delgado, Yelitza [1 ]
Gallignani, Maximo [1 ]
Manuel Estela, Jose [2 ]
Cerda Martin, Victor [2 ]
机构
[1] Univ Los Andes, Fac Ciencias, Lab Espect Mol, Dept Quim, Merida 5101 A, Venezuela
[2] Univ Islas Baleares, Fac Ciencias, Dept Quim, Palma de Mallorca, Islas Baleares, Spain
关键词
ANTIEPILEPTIC DRUGS; CAPILLARY-ELECTROPHORESIS; PLASMA-CONCENTRATIONS; EPILEPSY; PHARMACOKINETICS; CARBAMAZEPINE; ANTICONVULSANTS; METABOLITES; EXTRACTION; SAMPLES;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study describes a simple and sensitive column-switching high-performance liquid chromatographic method with UV detection for the determination of Lamotrigine in 50 mu L of serum. After solid-phase extraction of Lamotrigine on an Oasis HLB extraction precolumn (20 x 3.9 mm; dp: 25 mu m), chromatographic separation was achieved at 30 degrees C on a Chromolith RP-18e column (50 mm x 4.6 mm i.d.) using a solution of 20% acetonitrile in 15 mM phosphate buffer (pH 7.0) as the mobile phase, at a flow-rate of 2.0 mL/min. The eluant was detected at 215 nm. The retention time for Lamotrigine was 1.28 min. The total analysis time was ca. 5 min. However, the overlap of sample preparation, analysis, and reconditioning of the precolumn increased the overall sample throughput to one injection every 3 min. The method was validated for system suitability, linearity, precision, accuracy, robustness, and limit of quantitation. The linearity of the calibration lines, expressed by the linear correlation coefficient, was better than 0.9996. Recovery studies achieved from Lamotrigine spiked plasma samples showed values greater than 93%, demonstrating the excellent extraction efficiency of the precolumn. Intra- and inter-day precision were generally acceptable; the coefficient of variation was < 2.3% in all cases. The detection limits for Lamotrigine at a signal-to-noise ratio of 3 was 0.002 mu g/mL when a sample volume of 50 mu L was injected. However, it was possible to enhance the sensitivity further by injecting larger volumes, up to 200 mu L. The method was shown to be robust and the results were within the acceptable range. The method was successfully applied to the determination of Lamotrigine in human serum samples of patients submitted to Lamotrigine therapy.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [1] Determination of lamotrigine in human serum by high-performance liquid chromatography tandem mass spectrometry
    Lee, Woonhyoung
    Kim, Jeong-Ho
    Kim, Hyon-Suk
    Kwon, Oh Hun
    Lee, Byung In
    Heo, Kyoung
    NEUROLOGICAL SCIENCES, 2010, 31 (06) : 717 - 720
  • [2] Column-switching high-performance liquid chromatography of ofloxacin in human saliva and correlation of ofloxacin level in saliva and serum
    Ohkubo, T
    Suno, M
    Kudo, M
    Uno, T
    Sugawara, K
    THERAPEUTIC DRUG MONITORING, 1996, 18 (05) : 598 - 603
  • [3] Optimized high-performance liquid chromatographic method for determination of lamotrigine in serum with concomitant determination of phenytoin, carbamazepine, and carbamazepine epoxide
    Lensmeyer, GL
    Gidal, BE
    Wiebe, DA
    THERAPEUTIC DRUG MONITORING, 1997, 19 (03) : 292 - 300
  • [4] Rapid and sensitive high-performance liquid chromatographic method for the determination of ritonavir in human plasma
    Penzak, SR
    Lawhorn, WD
    Gubbins, PO
    INTERNATIONAL JOURNAL OF CLINICAL PHARMACOLOGY AND THERAPEUTICS, 2001, 39 (09) : 400 - 405
  • [5] High-performance liquid chromatographic method for the determination of sorafenib in human serum and peritoneal fluid
    Heinz, Werner J.
    Kahle, Kathrin
    Helle-Beyersdorf, Annegret
    Schirmer, Diana
    Lenker, Ulrike
    Keller, Daniela
    Langmann, Peter
    Klinker, Hartwig
    CANCER CHEMOTHERAPY AND PHARMACOLOGY, 2011, 68 (01) : 239 - 245
  • [6] Rapid determination of theophylline and antiepiletic drugs in serum by column-switching HPLC
    Chiba, R
    Yamazaki, H
    Umino, M
    Urayama, I
    Tanaka, A
    BUNSEKI KAGAKU, 2000, 49 (03) : 195 - 199
  • [7] Determination of lamotrigine in human serum by high-performance liquid chromatography–tandem mass spectrometry
    Woonhyoung Lee
    Jeong-Ho Kim
    Hyon-Suk Kim
    Oh Hun Kwon
    Byung In Lee
    Kyoung Heo
    Neurological Sciences, 2010, 31 : 717 - 720
  • [8] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF STOBADIN PHARMACOKINETICS IN SERUM
    SOLTES, L
    KALLAY, Z
    BEZEK, S
    FEDELESOVA, V
    BIOPHARMACEUTICS & DRUG DISPOSITION, 1991, 12 (01) : 29 - 35
  • [9] A High-Performance Liquid Chromatography Assay Method for the Determination of Lidocaine in Human Serum
    Al Nebaihi, Hamdah M.
    Primrose, Matthew
    Green, James S.
    Brocks, Dion R.
    PHARMACEUTICS, 2017, 9 (04)
  • [10] Narrow-bore high performance liquid chromatographic method for the determination of cetirizine in human plasma using column switching
    Kim, CK
    Yeon, KJ
    Ban, E
    Hyun, MJ
    Kim, JK
    Kim, MK
    Jin, SE
    Park, JS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) : 603 - 609