Field method comparison between passive air samplers and continuous monitors for VOCs and NO2 in El Paso, Texas

被引:70
作者
Mukerjee, S
Smith, LA
Norris, GA
Morandi, MT
Gonzales, M
Noble, CA
Neas, LM
Özkaynak, AH
机构
[1] US EPA, Off Res & Dev, Natl Exposure Res Lab,Exposure Modeling Res Branc, Human Exposure & Atmospher Sci Div,, Res Triangle Pk, NC 27711 USA
[2] ManTech Environm Technol Inc, Durham, NC USA
[3] US EPA, Off Res & Dev, Natl Exposure Res Lab,Environm Characterizat & Ap, Human Exposure & Atmospher Sci Div,, Res Triangle Pk, NC 27711 USA
[4] Univ Texas, Hlth Sci Ctr, Sch Publ Hlth, Houston, TX USA
[5] Univ New Mexico, Sch Med, Dept Internal Med, Albuquerque, NM 87131 USA
[6] RTI Int, Ctr Aerosol Technol, Res Triangle Pk, NC USA
[7] US EPA, Natl Hlth & Environm Effects Res Lab, Human Studies Div, Epidemiol & Biomarkers Branch, Res Triangle Pk, NC 27711 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 2004年 / 54卷 / 03期
关键词
D O I
10.1080/10473289.2004.10470903
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluates the performance of Model 3300 Ogawa Passive Nitrogen Dioxide (NO2) Samplers and 3M 3520 Organic Vapor Monitors (OVMs) by comparing integrated passive sampling concentrations to averaged hourly NO, and volatile organic compound (VOC) measurements at two sites in El Paso, TX. Sampling periods were three time intervals (3-day weekend, 4-day weekday, and 7-day weekly) for three consecutive weeks. OVM concentrations were corrected for ambient pressure to account for higher elevation. Precise results (<5% relative standard deviation, RSD) were found for NO, measurements from collocated Ogawa samplers. Reproducibility was lower from duplicate OVMs for BTEX (benzene, toluene, ethylbenzene, and xylene isomers) VOCs ( greater than or equal to7% RSD for 2-day samples) with better precision for longer sampling periods. Comparison of Ogawa NO2 samplers with chemiluminescence measurements averaged over the same time period suggested potential calibration problems with the chemiluminescence analyzer. For BTEX species, generally good agreement was obtained between OVMs and automated-gas chromatograph (auto-GC) measurements. The OVMs successfully tracked increasing levels of VOCs recorded by the auto-GCs. However, except for toluene, OVM BTEX measurements generally exceeded their continuous counterparts with a mean bias of 5-10%. Although interpretation of the study results was limited due to small sample sizes, diffusion barrier influences caused by shelters that housed OVMs and differences in sampling heights between OVMs and auto-GC inlet may explain the overestimation.
引用
收藏
页码:307 / 319
页数:13
相关论文
共 53 条
[1]  
BIRD RB, 1960, TRANSPORT PHENOMENA, P554
[2]   Validation of nitrogen dioxide diffusion tube methodology in the UK [J].
Bush, T ;
Smith, S ;
Stevenson, K ;
Moorcroft, S .
ATMOSPHERIC ENVIRONMENT, 2001, 35 (02) :289-296
[3]   Evaluation of a passive sampler for volatile organic compounds at ppb concentrations, varying temperatures, and humidities with 24-h exposures. 1. Description and characterization of exposure chamber system [J].
Chung, CW ;
Morandi, MT ;
Stock, TH ;
Afshar, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (20) :3661-3665
[4]   Evaluation of a passive sampler for volatile organic compounds at ppb concentrations, varying temperatures, and humidities with 24-h exposures. 2. Sampler performance [J].
Chung, CW ;
Morandi, MT ;
Stock, TH ;
Afshar, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1999, 33 (20) :3666-3671
[5]   INDOOR OUTDOOR MEASUREMENTS OF VOLATILE ORGANIC-COMPOUNDS IN THE KANAWHA VALLEY OF WEST-VIRGINIA [J].
COHEN, MA ;
RYAN, PB ;
YANAGISAWA, Y ;
SPENGLER, JD ;
OZKAYNAK, H ;
EPSTEIN, PS .
JAPCA-THE JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1989, 39 (08) :1086-1093
[6]   THE VALIDATION OF A PASSIVE SAMPLER FOR INDOOR AND OUTDOOR CONCENTRATIONS OF VOLATILE ORGANIC-COMPOUNDS [J].
COHEN, MA ;
RYAN, PB ;
YANAGISAWA, Y ;
HAMMOND, SK .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1990, 40 (07) :993-997
[7]   TRANSPORTATION-RELATED VOLATILE HYDROCARBON SOURCE PROFILES MEASURED IN ATLANTA [J].
CONNER, TL ;
LONNEMAN, WA ;
SEILA, RL .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1995, 45 (05) :383-394
[8]   Reevaluation of the employment of Fick's law for diffusion dosimeters [J].
Cross, JH .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (08) :1633-1638
[9]  
DEBORTOLI M, 1998, ENV QUALITY LIFE, P22
[10]  
DRAPER NR, 1981, APPL REGRESSION ANAL, P33