A method for manufacturing crowns and fixed partial dentures based on CAD/CAM has been developed as an alternative to the lost wax technique and the casting of an alloy, In this process two steps are included: milling and spark erosion. The computer-assisted design (CAD) relies heavily on the accuracy of the milling and spark erosion processes to achieve a clinically acceptable restoration, These two processes must be able to produce the crown data generated in the CAD files. This study evaluated the accuracy of the Procera CAD/CAM system in creating specific geometric bodies that were compared with the known dimensions in the CAD files for these bodies, The manufacturing errors of milling (ellipse +/-6.5 mu m, square +/-3.4 mu m, and cylinder +/-5.8 mu m) and spark erosion (ellipse +/-8.6 mu m and square +/-10.4 mu m) were determined. The accuracy of this manufacturing process demonstrated that this system was capable of producing a crown with a clinically accepted range for marginal opening gap dimension of less than 100 mu m.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 19 条
  • [1] A NEW ALL-CERAMIC CROWN - A DENSE-SINTERED, HIGH-PURITY ALUMINA COPING WITH PORCELAIN
    ANDERSSON, M
    ODEN, A
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (01) : 59 - 64
  • [2] CLINICAL-RESULTS WITH TITANIUM CROWNS FABRICATED WITH MACHINE DUPLICATION AND SPARK EROSION
    ANDERSSON, M
    BERGMAN, B
    BESSING, C
    ERICSON, G
    LUNDQUIST, P
    NILSON, H
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1989, 47 (05) : 279 - 286
  • [3] A 2-YEAR FOLLOW-UP-STUDY OF TITANIUM CROWNS
    BERGMAN, B
    BESSING, C
    ERICSON, G
    LUNDQUIST, P
    NILSON, H
    ANDERSSON, M
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1990, 48 (02) : 113 - 117
  • [4] DURET F, 1992, ARTET TECHNIQUE DENT, V4, P241
  • [5] THE FIT OF PROCERA TITANIUM CROWNS - AN INVITRO AND CLINICAL-STUDY
    KARLSSON, S
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1993, 51 (03) : 129 - 134
  • [6] KORBER E, 1986, DEUT ZAHNAERZTL Z, V41, P525
  • [7] Kunzelmann K H, 1990, Dtsch Zahnarztl Z, V45, P277
  • [8] MALEY K, 1995, P 52 ANN C ANTEC 94
  • [9] ESTIMATION OF CEMENT FILM THICKNESS BY AN IN-VIVO TECHNIQUE
    MCLEAN, JW
    FRAUNHOFER, JA
    [J]. BRITISH DENTAL JOURNAL, 1971, 131 (03) : 107 - +
  • [10] Mormann W H, 1989, Quintessence Int, V20, P329