A thin-layer contactless conductivity cell for detection in flowing liquids

被引:9
作者
Mika, J. [1 ]
Opekar, F. [1 ]
Coufal, P. [1 ]
Stulik, K. [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
关键词
Electrochemical detector; Contactless conductivity detection; Thin-layer detector; Analysis in flowing liquids; Liquid chromatography; CAPILLARY-ELECTROPHORESIS; STATIONARY-PHASE; CHROMATOGRAPHY; INJECTION; PEPTIDES; GEOMETRY; UV;
D O I
10.1016/j.aca.2009.07.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design is described of a thin-layer contactless conductivity detector suitable for liquid chromatography and flow-injection analysis. Its principal analytical parameters have been determined using a potassium chloride solution: the linear dynamic range extends from 7.5 x 10(-6) to 1.5 x 10(-2) S m(-1), corresponding to the KCl concentration range from 0.5 to 1000 mu M, the limit of detection equals 3.5 x 10(-6) S m(-1) (0.2 mu M KCl), the detection repeatability, expressed in terms of the relative standard deviation, amounts to 1.13% and the detection volume is 0.6 mu L. The detector was applied to detection of ionic compounds, benzoic, lactic and octanesulfonic acids, and sodium capronate, after their separation by liquid chromatography in a Biospher PSI 100C 18 columns using a 60% aqueous acetonitrile mobile phase. The frequency characteristics of the detector are reasonably theoretically described on the basis of a simple model which is commonly used in the field of contactless impedance detectors. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
[21]   Optimization of a capillary zone electrophoresis-contactless conductivity detection method for the determination of nisin [J].
Drevinskas, Tomas ;
Stankevicius, Mantas ;
Bimbiraite-Surviliene, Kristina ;
Naujokaityte, Gintare ;
Kaskoniene, Vilma ;
Kondrotiene, Kristina ;
Serniene, Loreta ;
Kornysova, Olga ;
Malakauskas, Mindaugas ;
Maruska, Audrius .
ELECTROPHORESIS, 2018, 39 (19) :2425-2430
[22]   Capacitively coupled contactless conductivity detection for analytical techniques - Developments from 2018 to 2020 [J].
Hauser, Peter C. ;
Kuban, Pavel .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1632
[23]   Determination of Neutral Saccharides by Capillary Electrophoresis with Contactless Conductivity Detection [J].
Malkova, Klara ;
Samcova, Eva ;
Tuma, Petr .
MODERN ELECTROCHEMICAL METHODS XXXI, 2011, :74-77
[24]   Evaluation of the detection of biomolecules in capillary electrophoresis by contactless conductivity measurement [J].
Abad-Villar, Eva M. ;
Kuban, Pavel ;
Hauser, Peter C. .
JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) :1031-1037
[25]   Monosaccharide profiling of glycoproteins by capillary electrophoresis with contactless conductivity detection [J].
Tomnikova, Alice ;
Kozlik, Petr ;
Krizek, Tomas .
ELECTROPHORESIS, 2022, 43 (20) :1963-1970
[26]   Rapid Detection of AGs using Microchip Capillary Electrophoresis Contactless Conductivity Detection [J].
Zhu, Gangzhi ;
Bao, Chunjie ;
Liu, Wenfang ;
Yan, Xingxing ;
Liu, Lili ;
Xiao, Jian ;
Chen, Chuanpin .
CURRENT PHARMACEUTICAL ANALYSIS, 2019, 15 (01) :9-16
[27]   Determination of PCR Products by Capillary Electrophoresis with Contactless Conductivity Detection [J].
Stojkovic, Marko ;
Uda, Narasimha Rao ;
Brodmann, Peter ;
Hauser, Peter C. .
CHIMIA, 2013, 67 (06) :428-428
[28]   Analysis of fatty acids by capillary electrophoresis with contactless conductivity detection [J].
Oliveira, MAL ;
do Lago, CL ;
Tavares, MFM ;
da Silva, JAF .
QUIMICA NOVA, 2003, 26 (06) :821-824
[29]   The detection of nerve agent degradation products in different soil fractions using capillary electrophoresis with contactless conductivity detection [J].
Seiman, Andrus ;
Makarotseva, Natalja ;
Vaher, Merike ;
Kaljurand, Mihkel .
CHEMISTRY AND ECOLOGY, 2010, 26 :145-155
[30]   Study on equivalent circuitry model of cell for capacitively coupled contactless conductivity detection [J].
Zhang, Hai-Feng ;
Liu, Xiao-Wei ;
Li, Hai-Tao ;
Wang, Wei ;
Wang, Xi-Lian ;
Tian, Li .
PROCEEDINGS OF THE FIRST SHENYANG INTERNATIONAL COLLOQUIUM ON MICROFLUIDICS, 2007, :72-75