On-line preconcentration of pharmaceutical residues from large volume water samples using short reversed-phase monolithic cartridges coupled to LC-UV-ESI-MS

被引:86
作者
Bones, Jonathan
Thomas, Kevin
Nesterenko, Pavel N.
Paull, Brett [1 ]
机构
[1] Dublin City Univ, Sch Chem Sci, Natl Ctr Sensor Res, Dublin 9, Ireland
[2] Norwegian Inst Water Res, NIVA, NO-0411 Oslo, Norway
关键词
pharmaceuticals; LC-UV-ESI-MS; on-line SPE; preconcentration; monolithic reversed-phase silica;
D O I
10.1016/j.talanta.2006.02.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simplified preconcentration method for a range of ultra-trace level pharmaceuticals in natural waters has been developed. Solid phase extraction was performed on-line using a micro-reversed-phase monolithic silica column, allowing for very rapid trace enrichment front large Volume (500 ml) samples with minimal sample handling. Acceptable recoveries of > 70% were obtained for the majority of compounds investigated and the monolithic columns could be washed and conditioned on-line with no sample carryover and used reproducibly for up to eight extractions each. The on-line SPE-LC-UV method was coupled to electrospray ionisation ion trap mass spectrometry (ESI-MS) to increase both selectivity and specificity. Detection limits were determined in spiked river and tap water samples and found to lie in the low ng/l region using sample volumes of 500 ml., loaded at a flow rate of 10 ml/min, and therefore, were suitable for ultra trace analysis. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1117 / 1128
页数:12
相关论文
共 59 条
  • [1] *ADV CHEM DEV LAB, ACD PKA DB VS EXPT A
  • [2] Evaluation of triclosan and biphenylol in marine sediments and urban wastewaters by pressurized liquid extraction and solid phase extraction followed by gas chromatography mass spectrometry and liquid chromatography mass spectrometry
    Agüera, A
    Fernández-Alba, AR
    Piedra, L
    Mézcua, M
    Gómez, MJ
    [J]. ANALYTICA CHIMICA ACTA, 2003, 480 (02) : 193 - 205
  • [3] Development and application of a new on-line SPE system combined with LC-MS/MS detection for high throughput direct analysis of pharmaceutical compounds in plasma
    Alnouti, Y
    Srinivasan, K
    Waddell, D
    Bi, HG
    Kavetskaia, O
    Gusev, AI
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2005, 1080 (02) : 99 - 106
  • [4] Automated on-line SPE LC-MS/MS method to quantitate 6beta-hydroxycortisol and cortisol in human urine: Use of the 6beta-hydroxycortisol to cortisol ratio as an indicator of CYP3A4 activity
    Barrett, YC
    Akinsanya, B
    Chang, SY
    Vesterqvist, O
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 821 (02): : 159 - 165
  • [5] Selected drugs in solid matrices: a review of environmental determination, occurrence and properties of principal substances
    Beausse, J
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2004, 23 (10-11) : 753 - 761
  • [6] Ultrasonic extraction of veterinary antibiotics from soils and pig slurry with SPE clean-up and LC-UV and fluorescence detection
    Blackwell, PA
    Lützhoft, HCH
    Ma, HP
    Halling-Sorensen, B
    Boxall, ABA
    Kay, P
    [J]. TALANTA, 2004, 64 (04) : 1058 - 1064
  • [7] Fast and robust simultaneous determination of three veterinary antibiotics in groundwater and surface water using a tandem solid-phase extraction with high-performance liquid chromatography-UV detection
    Blackwell, PA
    Lützhoft, HCH
    Ma, HP
    Halling-Sorensen, B
    Boxall, ABA
    Kay, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) : 111 - 117
  • [8] BONES J, IN PRESS INT J ENV A
  • [9] Naproxen removal from water by chlorination and biofilm processes
    Boyd, GR
    Zhang, SY
    Grimm, DA
    [J]. WATER RESEARCH, 2005, 39 (04) : 668 - 676
  • [10] Applications of silica-based monolithic HPLC columns
    Cabrera, K