Monolithic column with zwitterionic stationary phase for capillary electrochromatography

被引:55
作者
Fu, HJ [1 ]
Xie, CH [1 ]
Dong, J [1 ]
Huang, XD [1 ]
Zou, HF [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog R&A Ctr, Dalian 116011, Peoples R China
关键词
D O I
10.1021/ac0496695
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrochromatography (CEC) monolithic column with zwitterionic stationary phases was prepared by in situ polymerization of butyl methacrylate, ethylene dimethacrylate, methacrylic acid, and 2-(dimethyl amino) ethyl methacrylate in the presence of porogens. The stationary phases have zwitterionic functional groups, that is, both tertiary amine and acrylic acid groups, so the ionization of those groups on the zwitterionic stationary phase was affected by the pH values of the mobile phase, and further affects the strength and direction of the electroosmotic flow (EOF). Separations of alkylbenzenes and polycylic aromatic hydrocarbons based on the hydrophobic mechanism were obtained. Separation of various types of polar compounds, including phenols, anilines, and peptides, on the prepared column were performed under CEC mode with anodic and cathodic EOF, and different separation selectivities of those polar analytes were observed on the monolithic capillary column by using mobile phases with different pH values.
引用
收藏
页码:4866 / 4874
页数:9
相关论文
共 34 条
  • [1] Bedair M, 2002, ELECTROPHORESIS, V23, P2938, DOI 10.1002/1522-2683(200209)23:17<2938::AID-ELPS2938>3.0.CO
  • [2] 2-8
  • [3] Packing columns for capillary electrochromatography
    Colón, LA
    Maloney, TD
    Fermier, AM
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 43 - 53
  • [4] Capillary electrochromatography - A high-efficiency micro-separation technique
    Dittmann, MM
    Rozing, GP
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 744 (1-2) : 63 - 74
  • [5] Reversed-phase electrochromatography of proteins on modified continuous beds using normal-flow and counterflow gradients.: Theoretical and practical considerations
    Ericson, C
    Hjertén, S
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1621 - 1627
  • [6] Capillary electrochromatography in the pharmaceutical industry. Practical reality or fantasy?
    Euerby, MR
    Johnson, CM
    Bartle, KD
    Myers, P
    Roulin, SCP
    [J]. ANALYTICAL COMMUNICATIONS, 1996, 33 (11): : 403 - 405
  • [7] Capillary columns with in situ formed porous monolithic packing for micro high-performance liquid chromatography and capillary electrochromatography
    Gusev, I
    Huang, X
    Horváth, C
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) : 273 - 290
  • [8] Polymeric monolithic stationary phases for capillary electrochromatography
    Hilder, EF
    Svec, F
    Fréchet, JMJ
    [J]. ELECTROPHORESIS, 2002, 23 (22-23) : 3934 - 3953
  • [9] Acrylamide-based monoliths as robust stationary phases for capillary electrochromatography
    Hoegger, D
    Freitag, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 914 (1-2) : 211 - 222
  • [10] ELECTROSTATIC ION CHROMATOGRAPHY
    HU, WZ
    TAKEUCHI, T
    HARAGUCHI, H
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (17) : 2204 - 2208