Dynamic performances of trigeneration systems using different prime movers for high-rise building application: A comparative study

被引:11
作者
Fong, K. F. [1 ]
Lee, C. K. [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Tat Chee Ave, Kowloon, Hong Kong, Peoples R China
关键词
trigeneration; dynamic simulation; prime movers; thermodynamic analysis; primary energy saving; carbon emissions cut; SMALL-SCALE APPLICATIONS; POWER-SYSTEM; HONG-KONG; OPERATION STRATEGIES; ENERGY EFFICIENCY; STIRLING ENGINE; CCHP SYSTEMS; GAS-TURBINE; OPTIMIZATION; GENERATION;
D O I
10.1007/s12273-017-0350-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
Trigeneration is a strategic deployment to achieve the energy saving target in response to climate change mitigation. Appropriate choice of prime movers is paramount to make trigeneration feasible. It is common for trigeneration to be considered in district-wide application; however, there is little study on the effectiveness of various available prime movers in building-scale use. As such, diesel engine (DE), gas engine (GE), gas turbine with recuperator, and combined gas turbine cycle (CGTC) were involved as prime mover options for trigeneration in this study. Through year-round dynamic simulation, the energy and environmental performances of different trigeneration systems were thoroughly evaluated for a high-rise hotel building in subtropical climate. It was found that the DE-primed trigeneration would have the highest primary energy saving, while the CGTC-primed trigeneration would be the largest in carbon emissions cut. However, the GE-primed trigeneration system was deemed to be the best choice with both energy merit and system simplicity. It was also found that the part-load performance of prime mover and the required fuel type were closely associated to the annual energy and environmental performances.
引用
收藏
页码:509 / 523
页数:15
相关论文
共 45 条
[31]   Thermodynamic analysis of a new combined cooling, heat and power system driven by solid oxide fuel cell based on ammonia-water mixture [J].
Ma, Shaolin ;
Wang, Jiangfeng ;
Yan, Zhequan ;
Dai, Yiping ;
Lu, Bingheng .
JOURNAL OF POWER SOURCES, 2011, 196 (20) :8463-8471
[32]   Evaluation of a turbine driven CCHP system for large office buildings under different operating strategies [J].
Mago, Pedro J. ;
Hueffed, Anna K. .
ENERGY AND BUILDINGS, 2010, 42 (10) :1628-1636
[33]   Assessment of CCHP systems based on biomass combustion for small-scale applications through a review of the technology and analysis of energy efficiency parameters [J].
Maraver, Daniel ;
Sin, Ana ;
Royo, Javier ;
Sebastian, Fernando .
APPLIED ENERGY, 2013, 102 :1303-1313
[34]   Performance analysis of a trigeneration system based on a micro gas turbine and an air-cooled, indirect fired, ammonia-water absorption chiller [J].
Moya, M. ;
Bruno, J. C. ;
Eguia, P. ;
Torres, E. ;
Zamora, I. ;
Coronas, A. .
APPLIED ENERGY, 2011, 88 (12) :4424-4440
[35]   Building-integrated trigeneration system: Energy, environmental and economic dynamic performance assessment for Italian residential applications [J].
Sibilio, Sergio ;
Rosato, Antonio ;
Ciampi, Giovanni ;
Scorpio, Michelangelo ;
Akisawa, Atsushi .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 68 :920-933
[36]   Multi-objective operation optimization and evaluation of large-scale NG distributed energy system driven by gas-steam combined cycle in China [J].
Tan, Zhong-fu ;
Zhan, Hui-juan ;
Shi, Quan-sheng ;
Song, Yi-hang ;
Ju, Li-wei .
ENERGY AND BUILDINGS, 2014, 76 :572-587
[37]  
TRNSYS, 2011, TRNSYS 17 TRANSIENT
[38]  
Turie S. E., 2011, THESIS
[39]   Operational optimization in simple tri-generation systems [J].
Unal, Ali Nadi ;
Ersoz, Ibrahim ;
Kayakutlu, Gulgun .
APPLIED THERMAL ENGINEERING, 2016, 107 :175-183
[40]  
USDE USEPA, 2012, COMB HEAT POW CLEAN