RayStation: External beam treatment planning system

被引:60
作者
Bodensteiner, Dayna [1 ]
机构
[1] RaySearch Amer, Stockholm, Sweden
关键词
Treatment planning system; RaySearch; RayStation; Robustness; Automation; Speed; MCO; Multicriteria optimization; VMAT; IMRT; Proton; Monte Carlo; Automatic breast; Structure definition; Fallback planning; Tomotherapy; Plan explorer;
D O I
10.1016/j.meddos.2018.02.013
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
RaySearch Laboratories is a world leader in the field of advanced software and creator of the RayStation treatment planning system for radiation therapy. The aim with RayStation is to deliver an unmatched user experience and leading functionality. Unique features described here include multiatlas based autosegmentation for contouring, deformable registration with 2 different algorithms, multicriteria optimization, Plan Explorer, fallback planning, ultrafast computation speed, and 4-dimensional (4D) adaptive radiation therapy. RayStation can be used to plan for electrons and photons on traditional linacs, for protons on various delivery systems, and for Accuray's helical TomoTherapy system. This paper describes some of these modalities, with reference to clinical cases and including descriptions of the impact on workflow. (C) 2018 American Association of Medical Dosimetrists.
引用
收藏
页码:168 / 176
页数:9
相关论文
共 6 条
[1]  
Craft D., 2011, INT J RADIAT ONCOL, V82, pe83
[2]   Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans [J].
Purdie, Thomas G. ;
Dinniwell, Robert E. ;
Fyles, Anthony ;
Sharpe, Michael B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (03) :688-695
[3]   AUTOMATED PLANNING OF TANGENTIAL BREAST INTENSITY-MODULATED RADIOTHERAPY USING HEURISTIC OPTIMIZATION [J].
Purdie, Thomas G. ;
Dinniwell, Robert E. ;
Letourneau, Daniel ;
Hill, Christine ;
Sharpe, Michael B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02) :575-583
[4]   Dosimetric evaluation of a commercial proton spot scanning Monte-Carlo dose algorithm: comparisons against measurements and simulations [J].
Saini, Jatinder ;
Maes, Dominic ;
Egan, Alexander ;
Bowen, Stephen R. ;
St James, Sara ;
Janson, Martin ;
Wong, Tony ;
Bloch, Charles .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (19) :7659-7681
[5]   Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy [J].
Shirey, Robert J. ;
Wu, Hsinshun Terry .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01) :164-173
[6]   Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung [J].
Taylor, Paige A. ;
Kry, Stephen F. ;
Followill, David S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (03) :750-756