Multi-slice computed tomography technology is emerging as a realistic investigation in patients with suspected disease in native, stented or grafted coronary arteries. A non-invasive diagnostic tool. is desirable as these patients are at high risk for complications of invasive angiography. A 64-stice CT may achieve the desired diagnostic accuracy, and overcome the limitations of spatial resolution, respiratory motion, artifacts from calcification and stents, and radiation dose considerations to produce reliable image quality. These advances, as well as the capacity for integrated functional cardiac assessment, may change the referral patterns in patients who have had previous bypass surgery or percutaneous intervention. This review outlines the debated issues about 64-stice cardiac CT in patients before and after coronary artery bypass surgery, as well. as coronary stenting and functional assessment. A review of the recent literature on native coronary artery and bypass graft assessment by multislice CT is also performed. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 64 条
[1]   Coronary artery bypass graft (CABG) patency: Assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography [J].
Anders, K ;
Baum, U ;
Schmid, M ;
Ropers, D ;
Schmid, A ;
Pohle, K ;
Daniel, WG ;
Bautz, W ;
Achenbach, S .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 57 (03) :336-344
[2]   Modification of surgical planning based on cardiac multidetector computed tomography in reoperative heart surgery [J].
Aviram, G ;
Sharony, R ;
Kramer, A ;
Nesher, N ;
Loberman, D ;
Ben-Gal, Y ;
Graif, M ;
Uretzky, G ;
Mohr, R .
ANNALS OF THORACIC SURGERY, 2005, 79 (02) :589-595
[3]   Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolution [J].
Burgstahler, C ;
Beek, T ;
Kuettner, A ;
Drosch, T ;
Kopp, AF ;
Heuschmid, M ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 106 (02) :244-249
[4]   Non-invasive evaluation of coronary artery bypass grafts using multi-slice computed tomography: initial clinical experience [J].
Burgstahler, C ;
Kuettner, A ;
Kopp, AF ;
Herdeg, C ;
Martensen, J ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 90 (2-3) :275-280
[5]   Effect of HMG-Coa reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography [J].
Callister, TQ ;
Raggi, P ;
Cooil, B ;
Lippolis, NJ ;
Russo, DJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1972-1978
[6]   Follow-up of coronary artery bypass graft patency by multislice computed tomography [J].
Chiurlia, E ;
Menozzi, M ;
Ratti, C ;
Romagnoli, R ;
Modena, MG .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (09) :1094-1097
[7]   Serial angiographic follow-up of grafts one year and five years after coronary artery bypass surgery [J].
Cho, KR ;
Kim, JS ;
Choi, JS ;
Kim, KB .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2006, 29 (04) :511-516
[8]   Atherosclerotic plaque characterization by multidetector row computed tomography angiography [J].
Cordeiro, MAS ;
Lima, JAC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (08) :C40-C47
[9]   Non-invasive coronary artery imaging with electron beam computed tomography and magnetic resonance imaging [J].
de Feyter, PJ ;
Nieman, K ;
van Ooijen, P ;
Oudkerk, M .
HEART, 2000, 84 (04) :442-448
[10]   Cardiac applications of multislice computed tomography [J].
de Roos, A ;
Kroft, LJM ;
Bax, JJ ;
Lamb, HJ ;
Geleijns, J .
BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (937) :9-16