Discrepancy between radioimmunoassay and high performance liquid chromatography tandem-mass spectrometry for the analysis of androstenedione

被引:21
作者
Bruce, Stephen J. [1 ]
Rey, Francois [1 ]
Beguin, Alexandre [1 ]
Berthod, Christine [1 ]
Werner, Dominique [1 ]
Henry, Hugues [1 ]
机构
[1] CHU Vaudois, Univ Lausanne Hosp, CH-1011 Lausanne, Switzerland
关键词
LC-MS; Tandem mass spectrometry; Radioimmunoassay; Androstenedione; Stripped serum; LC-MS/MS; STEROID-HORMONES; TESTOSTERONE; SERUM; PLASMA;
D O I
10.1016/j.ab.2014.03.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The discrepancy of results for the quantification of androstenedione in human serum between a radioimmunoassay (RIA) method and high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) was investigated. RIA overestimated concentrations compared to LC-MS/MS on 59 clinical samples (RIA = 1.79 x LC-MS/MS 0.94). RIA kit and LC-MS/MS calibrants were also determined by both methods. The RIA performed with improved accuracy on the calibrants (RIA = 1.35 x LC-MS/MS - 0.28). Lipid, protein, electrolyte content, and pH of the two sets of calibrants were further investigated. The RIA calibrants contained little lipid material, while the LC-MS/MS calibrant material contained the same levels expected in normal serum/plasma. The pH and sex hormone binding globulin (SHBG) values were different between the RIA calibrants and the LC-MS/MS calibrant material (SHBG, 31 +/- 2 and 38 +/- 2 nmo1/1; pH, 8.27 +/- 0.18 and 8.66 +/- 0.03, respectively). No correlation was observed between androstenedione RIA and LC-MS/MS discrepancy and lipid or protein. LC-MS/MS sample preparation was tested for the removal of protein-bound material and recovery determined (99-108%). The corresponding RIA results overestimated androstenedione by 52-174% compared to LC-MS/MS. The results here demonstrate that LC-MS/MS is the more accurate method. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 2001, GUID IND BIOAN METH
[2]   EFFECTS OF RESIN OR CHARCOAL TREATMENT ON FETAL BOVINE SERUM AND BOVINE CALF SERUM [J].
Cao, Zhimin ;
West, Clint ;
Norton-Wenzel, Carol S. ;
Rej, Robert ;
Davis, Faith B. ;
Davis, Paul J. ;
Rej, Robert .
ENDOCRINE RESEARCH, 2009, 34 (04) :101-108
[3]   The coming of age of liquid chromatography coupled to tandem mass spectrometry in the endocrinology laboratory [J].
Carvalho, Valdemir Melechco .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 :50-58
[4]  
Couchman L, 2011, BIOANALYSIS, V3, P2549, DOI [10.4155/bio.11.254, 10.4155/BIO.11.254]
[5]   TRANSPORT OF STEROID-HORMONES - BINDING OF 21 ENDOGENOUS STEROIDS TO BOTH TESTOSTERONE-BINDING GLOBULIN AND CORTICOSTEROID-BINDING GLOBULIN IN HUMAN-PLASMA [J].
DUNN, JF ;
NISULA, BC ;
RODBARD, D .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1981, 53 (01) :58-68
[6]   Serum steroid profiling by isotopic dilution-liquid chromatography-mass spectrometry: Comparison with current immunoassays and reference intervals in healthy adults [J].
Fanelli, Flaminia ;
Belluomo, Ilaria ;
Di Lallo, Valentina D. ;
Cuomo, Gaia ;
De Iasio, Rosaria ;
Baccini, Margherita ;
Casadio, Elena ;
Casetta, Bruno ;
Vicennati, Valentina ;
Gambineri, Alessandra ;
Grossi, Gabriele ;
Pasquali, Renato ;
Pagotto, Uberto .
STEROIDS, 2011, 76 (03) :244-253
[7]  
Gallagher L. M., 2007, ANN CLIN BIOCH, V44
[8]   Prevalence and Incidence of Endocrine and Metabolic Disorders in the United States: A Comprehensive Review [J].
Golden, Sherita H. ;
Robinson, Karen A. ;
Saldanha, Ian ;
Anton, Blair ;
Ladenson, Paul W. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2009, 94 (06) :1853-1878
[9]   High-throughput UHPLC-MS/MS method for the detection, quantification and identification of fifty-five anabolic and androgenic steroids in equine plasma [J].
Guan, Fuyu ;
Uboh, Cornelius E. ;
Soma, Lawrence R. ;
You, Youwen ;
Liu, Ying ;
Li, Xiaoqing .
JOURNAL OF MASS SPECTROMETRY, 2010, 45 (11) :1270-1279
[10]   Simultaneous determination of 12 steroids by isotope dilution liquid chromatography-photo spray ionization tandem mass spectrometry [J].
Guo, Tiedong ;
Taylor, Robert L. ;
Singh, Ravinder J. ;
Soldin, Steven J. .
CLINICA CHIMICA ACTA, 2006, 372 (1-2) :76-82