Discrepancy between radioimmunoassay and high performance liquid chromatography tandem-mass spectrometry for the analysis of androstenedione

被引:20
|
作者
Bruce, Stephen J. [1 ]
Rey, Francois [1 ]
Beguin, Alexandre [1 ]
Berthod, Christine [1 ]
Werner, Dominique [1 ]
Henry, Hugues [1 ]
机构
[1] CHU Vaudois, Univ Lausanne Hosp, CH-1011 Lausanne, Switzerland
关键词
LC-MS; Tandem mass spectrometry; Radioimmunoassay; Androstenedione; Stripped serum; LC-MS/MS; STEROID-HORMONES; TESTOSTERONE; SERUM; PLASMA;
D O I
10.1016/j.ab.2014.03.021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The discrepancy of results for the quantification of androstenedione in human serum between a radioimmunoassay (RIA) method and high performance liquid chromatography tandem-mass spectrometry (LC-MS/MS) was investigated. RIA overestimated concentrations compared to LC-MS/MS on 59 clinical samples (RIA = 1.79 x LC-MS/MS 0.94). RIA kit and LC-MS/MS calibrants were also determined by both methods. The RIA performed with improved accuracy on the calibrants (RIA = 1.35 x LC-MS/MS - 0.28). Lipid, protein, electrolyte content, and pH of the two sets of calibrants were further investigated. The RIA calibrants contained little lipid material, while the LC-MS/MS calibrant material contained the same levels expected in normal serum/plasma. The pH and sex hormone binding globulin (SHBG) values were different between the RIA calibrants and the LC-MS/MS calibrant material (SHBG, 31 +/- 2 and 38 +/- 2 nmo1/1; pH, 8.27 +/- 0.18 and 8.66 +/- 0.03, respectively). No correlation was observed between androstenedione RIA and LC-MS/MS discrepancy and lipid or protein. LC-MS/MS sample preparation was tested for the removal of protein-bound material and recovery determined (99-108%). The corresponding RIA results overestimated androstenedione by 52-174% compared to LC-MS/MS. The results here demonstrate that LC-MS/MS is the more accurate method. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [1] Aldehyde analysis by high performance liquid chromatography/tandem mass spectrometry
    O'Brien-Coker, IC
    Perkins, G
    Mallet, AI
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (12) : 920 - 928
  • [2] Determination of Metoprolol in Human Plasma by Liquid Chromatography Tandem-Mass Spectrometry
    Narmada, P.
    Nalini, K.
    Rao, A. K. S. Bhujanga
    Jogi, K. V.
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL AND PHYTOPHARMACOLOGICAL RESEARCH, 2013, 3 (02): : 117 - 120
  • [3] Analysis of sodium 2-mercaptoethane sulfonate in rat plasma using high performance liquid chromatography tandem-mass spectrometry
    Donkor, Abigail B. B.
    White, Carl W. W.
    Nick, Heidi J. J.
    Logue, Brian A. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1189
  • [4] Gas chromatography-mass spectrometry and tandem-mass spectrometry for cannabinoid analysis and discovery
    Leghissa, Allegra
    Hildenbrand, Zacariah
    Schug, Kevin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [5] Simultaneous determination of androstenedione and testosterone by liquid chromatography tandem mass spectrometry
    Gallagher, L
    Owen, L
    Keevil, B
    CLINICA CHIMICA ACTA, 2005, 355 : S236 - S237
  • [6] Determination of organic acids in fruits and vegetables by liquid chromatography with tandem-mass spectrometry
    Flores, Pilar
    Hellin, Pilar
    Fenoll, Jose
    FOOD CHEMISTRY, 2012, 132 (02) : 1049 - 1054
  • [7] Analysis of 9-fluorenylmethyloxycarbonyl derivatives of catecholamines by high performance liquid chromatography, liquid chromatography/mass spectrometry and tandem mass spectrometry
    Chen, S
    Li, Q
    Carvey, PM
    Li, KW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (18) : 1869 - 1877
  • [8] Use of short high-performance liquid chromatography columns and tandem-mass spectrometry for the rapid analysis of a prostaglandin analog, fluprostenol, in rat plasma
    Eichhold, TH
    Kuhlenbeck, DL
    Baker, TR
    Stella, ME
    Amburgey, JS
    deLong, MA
    Hartke, JR
    Cruze, CA
    Pierce, SA
    Wehmeyer, KR
    JOURNAL OF CHROMATOGRAPHY B, 2000, 741 (02): : 213 - 220
  • [9] Hyperandrogenism by Liquid Chromatography Tandem Mass Spectrometry in PCOS: Focus on Testosterone and Androstenedione
    Grassi, Giorgia
    Polledri, Elisa
    Fustinoni, Silvia
    Chiodini, Iacopo
    Ceriotti, Ferruccio
    D'Agostino, Simona
    Filippi, Francesca
    Somigliana, Edgardo
    Mantovani, Giovanna
    Arosio, Maura
    Morelli, Valentina
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (01) : 1 - 9
  • [10] Analysis of 18 perfluorinated compounds in river waters: Comparison of high performance liquid chromatography-tandem mass spectrometry, ultra-high-performance liquid chromatography-tandem mass spectrometry and capillary liquid chromatography-mass spectrometry
    Onghena, Matthias
    Moliner-Martinez, Y.
    Pico, Yolanda
    Campins-Falco, P.
    Barcelo, Damia
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1244 : 88 - 97