Determination of two COX-2 inhibitors in serum and synovial fluid of patients with inflammatory arthritis by ultra performance liquid chromatography-inductively coupled plasma mass spectroscopy and quadrupole time-of-flight mass spectrometry

被引:29
作者
Gika, Helen G. [1 ,2 ]
Theodoridou, Athina [3 ]
Michopoulos, Filippos [1 ,2 ]
Theodoridis, Georgios [1 ,2 ]
Diza, Eudoxia [4 ]
Settas, Lucas [3 ]
Nikolaidis, Paul [3 ]
Smith, Christopher [2 ]
Wilson, Ian D. [2 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
[2] AstraZeneca, Dept Clin Phamacol Drug Metab & Pharmacokinet, Macclesfield SK10 4TG, Cheshire, England
[3] AHEPA Univ Hosp, Dept Internal Med 1, Thessaloniki 54636, Greece
[4] Aristotle Univ Thessaloniki, Dept Microbiol 2, Sch Med, Thessaloniki 54124, Greece
关键词
COX-2; inhibitors; Celecoxib; Etoricoxib; Rheumatoid arthritis; Ultra performance liquid chromatography (UPLC); Inductively coupled plasma mass spectroscopy (ICPMS); Quadrupole time-of-flight mass spectrometry (Q-TOF); SULFUR-SPECIFIC DETECTION; DYNAMIC REACTION CELL; ICP-DRC-MS; CYCLOOXYGENASE-2; INHIBITOR; SELECTIVE INHIBITOR; SPECIATION ANALYSIS; ETORICOXIB MK-0663; PHARMACOKINETICS; CELECOXIB; METABOLITES;
D O I
10.1016/j.jpba.2008.12.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of two sulphur-containing drugs, the COX-2 inhibitors celecoxib and etoricoxib, in the serum and synovial fluid of inflammatory arthritis patients, is described using a sensitive ultra performance liquid chromatography-inductively coupled plasma mass spectroscopy (UPLC/ICPMS) method. Confirmation of the identity of the analytes in the samples was also performed by electrospray quadruple time-of-flight mass spectrometry in positive electrospray ionisation mode. The two COX-2 inhibitors were extracted from serum and synovial fluid following dilution with acetate buffer (pH 5) and liquid-liquid extraction (LLE) into ethyl acetate. Extracted samples were then analysed using UPLC/ICPMS with sulphur-specific detection. The limit of detection by UPLC/ICPMS was 0.45 ng/ml of sulphur in both serum and synovial fluid. The UPLC/ICPMS method was applied to the analysis of samples from patients receiving either 200 mg/day of celecoxib (2x 100 mg), 90 mg/day etoricoxib or placebo. The range of concentrations detected in the samples for the two drugs was from 0.3 to 3.3 mu g/ml. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:579 / 586
页数:8
相关论文
共 40 条
[1]   Liquid chromatographic-mass spectrometric determination of celecoxib in plasma using single-ion monitoring and its use in clinical pharmacokinetics [J].
Abdel-Hamid, M ;
Novotny, L ;
Hamza, H .
JOURNAL OF CHROMATOGRAPHY B, 2001, 753 (02) :401-408
[2]   Pharmacokinetics of etoricoxib in patients with renal impairment [J].
Agrawal, NGB ;
Matthews, CZ ;
Mazenko, RS ;
Kline, WE ;
Woolf, EJ ;
Porras, AG ;
Geer, LA ;
Wong, PH ;
Cho, MH ;
Cote, J ;
Marbury, TC ;
Moncrief, JW ;
Alcorn, H ;
Swan, S ;
Sack, MR ;
Robson, RA ;
Petty, KJ ;
Schwartz, JI ;
Gottesdiener, KM .
JOURNAL OF CLINICAL PHARMACOLOGY, 2004, 44 (01) :48-58
[3]   Single- and multiple-dose pharmacokinetics of etoricoxib, a selective inhibitor of cyclooxygenase-2, in man [J].
Agrawal, NGB ;
Porras, AG ;
Matthews, CZ ;
Rose, MJ ;
Woolf, EJ ;
Musser, BJ ;
Dynder, AL ;
Mazina, KE ;
Lasseter, KC ;
Hunt, TL ;
Schwartz, JI ;
McCrea, JB ;
Gottesdiener, KM .
JOURNAL OF CLINICAL PHARMACOLOGY, 2003, 43 (03) :268-276
[4]   Determination of cobalamins using capillary electrophoresis inductively coupled plasma mass spectrometry [J].
Baker, SA ;
Miller-Ihli, NJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (12) :1823-1832
[5]   A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) - Part 1. The rf-field energy contribution in thermodynamics of ion-molecule reactions [J].
Baranov, VI ;
Tanner, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (08) :1133-1142
[6]   Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives [J].
Bendahl, L ;
Hansen, SH ;
Gammelgaard, B ;
Sturup, S ;
Nielsen, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) :648-652
[7]   UPLC-ICP-MS -: a fast technique for speciation analysis [J].
Bendahl, L ;
Stürup, S ;
Gammelgaard, B ;
Hansen, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (11) :1287-1289
[8]  
Bouyssiere B, 2003, ADV CHROMATOGR, V42, P107
[9]   Determination of etoricoxib in human plasma by liquid chromatography-tandem mass spectrometry with electrospray ionisation [J].
Bräutigam, L ;
Nefflen, JU ;
Geisslinger, G .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (02) :309-315
[10]   In vitro metabolism considerations, including activity testing of metabolites, in the discovery and selection of the COX-2 inhibitor etoricoxib (MK-0663) [J].
Chauret, N ;
Yergey, JA ;
Brideau, C ;
Friesen, RW ;
Mancini, J ;
Riendeau, D ;
Silva, J ;
Styhler, A ;
Trimble, LA ;
Nicoll-Griffith, DA .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2001, 11 (08) :1059-1062